PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

Fast and sensitive spectrofluorimetric determination of trace amount of Pb(II) in sludge using o-vanilin-8-aminoquinoline

Wybrane pełne teksty z tego czasopisma
Identyfikatory
Warianty tytułu
PL
Szybka i czuła spektrofluorymetryczna metoda oznaczania śladowych ilości Pb(II) w osdach za pomocą o-wanilino-8-aminochinoliny
Języki publikacji
EN
Abstrakty
EN
o-Vanillin-8-am inoqu incline (OVAQ) — a novel fluorescent reagent has been synthesised and applied to the determination of Pb(II). In ethanol-water medium of pH 9.00 Pb(ll) reacted with OVAQ (&lambdaex/em= 278/318 nm) to form a 1; 1 non-fluorescent complex. Fluorescence quenching was proportional to the concentration of Pb(ll) in the range from 5.3 to 180 &mug L-1. Detection limit was 1.6 μg L-1. Interfering effect of 25 foreign ions on the determination results were studied. The method was successively applied to the determination of lead in sludge.
PL
Zsyntetyzowano nowy odczynnik fiuorymetryczny o-wanilino-8-aminochinolinę (OVAQ) 1 wyznaczono jego stale dysocjacji kwasowej. Zbadano reakcję fluorescencji odczynnika w obecności jonów oiowiu. W wodno-etanolowym roztworze o pH 9.0 Pb(II) reaguje 2 fluoryzującym (&lambdaex/em= 278/318 nm) odczynnikiem tworząc nie fluoryzujący kompleks o składzie 1:1. Wyznaczono liniowy zakres wykresu analitycznego od 5,3 do 180 μg -1 i granicę wykrywalności wynoszącą 1,6 μg L-1. Badano interferencje 25 jonów. Metoda jest prosta i została z powodzeniem zastosowana do oznaczania ołowiu w osadach.
Czasopismo
Rocznik
Strony
631--639
Opis fizyczny
Bibliogr. 11 poz.
Twórcy
autor
  • College of Chemistry, Chemical Engineering and Materials Science, Shandong Normal University, Jinan, 250014 China
autor
  • College of Chemistry, Chemical Engineering and Materials Science, Shandong Normal University, Jinan, 250014 China
autor
  • College of Chemistry, Chemical Engineering and Materials Science, Shandong Normal University, Jinan, 250014 China
autor
  • College of Chemistry, Chemical Engineering and Materials Science, Shandong Normal University, Jinan, 250014 China
autor
  • College of Chemistry, Chemical Engineering and Materials Science, Shandong Normal University, Jinan, 250014 China
autor
  • College of Chemistry, Chemical Engineering and Materials Science, Shandong Normal University, Jinan, 250014 China
Bibliografia
  • 1. D.A. Gidlow, Occup. Med. (Lond), 54, 76 (2004).
  • 2. E. Feely, C. Garavan and K. Kelleher, Ir. Med. J., 96, 232 (2003).
  • 3. C.C. Harper, A. Mathee, Y.V. Schirnding, C.T. De Rosa and H. Falk, Int. J. Hyg. Environ. Health., 206, 315 (2003).
  • 4. C. Brittle, M. Zint, J. Environ. Health., 65, 17 (2003).
  • 5. B.E. Udom , J.S.C. Mbagwu, J.K. Adesodun and N.N. Agbim, Environ. Int., 30, 467 (2004).
  • 6. J. Medina, F.H. Hernandez, R. Marin and F.J. Lopez, Analyst, 111, 235 (1986).
  • 7. E. Andres, E. Fuente and D. Blanco, Anal. Lett., 27, 775 (1994).
  • 8. H.J. Wang, F. He and C.Q. Jiang, Analyst, 126, 1164 (2001).
  • 9. N.U. Persic-Janjic, A.A. Muk and V.D. Canic, Anal. Chem., 45, 798 (1973).
  • 10. G.Z. Chen, Z.X. Huang, Z.Z. Zheng, J.G. Xu and Z.B. Wang, Fluorescence Analysis Methods, Science Press, Peking, 1990.
  • 11. H.M.N.H. Irving, H. Freiser and T.S. West, IUPAC Compendium of Analytical Nomenclature, Definitive Rules, 1981.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BPP1-0049-0082
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.