Determination of selenium in human urine by electrothermal atomic absorption spectrometry

Wybrane pełne teksty z tego czasopisma
Identyfikatory
Warianty tytułu
PL
Oznaczanie selenu w moczu ludzkim za pomocą elektrotermicznej atomowej spektrometrii absorpcyjnej
Języki publikacji
EN
Abstrakty
EN
AGFAAS method for the direct determination of selenium in humane urine has been presented. Mixed Pd, Rh and Ir were thermally reduced and electrodepositcd as modifiers. Also an alternating air stream was used during the pyrolysis. The influence of modifiers (Pd, Rh and Ir) on the maximum pyrolysis temperature, sensitivity, background absorption and atomization signal shape were studied. Optimum performance of the method was achieved in the presence of thermally reduced Rh. Under optimum experimental conditions (pyrolysis in air at 300°C. pyrolysis in argon at 1300°C, and atomisation at 2200°C) detection limit (expressed as three times the standard deviation of 1.0% (v/v) HNO3, solution) was 7.5š 1.2 μL-1 for the 20 μ-in-volume sample. Characteristic mass was found to be 4.3 pg and 6.8 pg for aqueous standards and urine solutions, respectively.
PL
W pracy przedstawiono procedurę analityczną pozwalającą na bezpośrednie oznaczanie selenu w moczu metodą GAAAS. Istotnym elementem proponowanej procedury jest zastosowanie Pd, Rh lub Ir jako modyfikatorów oraz dodatku powietrza do gazu nośnego w etapie rozkładu próbki moczu. W pracy opisano badania dotyczące wpływu sposobu wprowadzania modyfikatora (Pd, Rh lub I r) na temperaturę etapu rozkładu termicznego, na czułość oznaczania oraz na kształt sygnałów tła i absorpej i atomowej. Z badanych modyfikatorów, najbardziej efektywny okazał się rod. Przy zastosowaniu optymalnych warunków (rozkiad termiczny w obecności powietrza w 300°C, rozkład termiczny wobecności argonu w 13QO°C i atomizacja w 2200°C), granica wykrywalności, wyrażona jako trzykrotna wartość odchylenia standardowego, przy założeniu objętości 20 μL próbki, dla roztworu1 .0% (v/v) HMO3, wynosi 7.5 š1.2 μ-1. Masa charakterystyczna dla oznaczania selenu w roztworze wodnym oraz w moczu wynosi odpowiednio 4.3 pg i 6.8 pg.
Czasopismo
Rocznik
Strony
235--247
Opis fizyczny
Bibliogr. 42 poz.
Twórcy
autor
  • Faculty of Chemistry, Warsaw University, ul. Pasteura 1. 02-093 Warsaw, Poland
  • Faculty of Chemistry, Warsaw University, ul. Pasteura 1. 02-093 Warsaw, Poland
autor
  • Faculty of Chemistry, Warsaw University, ul. Pasteura 1. 02-093 Warsaw, Poland
Bibliografia
  • 1. Rayman M.P., Lancet, 356, 233 (2000).
  • 2. Suadicani P., Hein H.O. and Gyntelberg F., Atherosclerosis, 96, 33 (1992).
  • 3. Foster L.H. and Sumar S., Crit. Rev. Food Sci. Nutr., 37, 211 (1998).
  • 4. Alaejos M.S. and Romero C.D., Clin. Chem., 39, 2040 (1993).
  • 5. Nixon D.E., Mayer T.P. and Burritt M.F., Spectrochim. Acta Part B, 54, 931 (1999).
  • 6. Sabč R., Rubio R. and Garcia-Beltrán L., Anal. Chim. Acta, 419, 121 (2000).
  • 7. Bulska E. and Pyrzyńska K., Spectrochim. Acta Part B, 52, 1283 (1997).
  • 8. Gammelgaard B. and Jřns O., J. Anal. Atom. Spectrom., 12, 465 (1997).
  • 9. Cabon J.Y. and Le BihanA., Anal. Chim. Acta, 402, 327 (1999).
  • 10. Fischer J.L. and Rademeyer C.J., Spectrochim. Acta Part B, 54, 975 (1999).
  • 11. Liu Y., Gong B., Xu L. and Lin T., Talanta, 43, 985 (1996).
  • 12. Héninger I., Potin-Gautier M., Astruc M., Galvez L. and Vignier V., J. Anal. Atom. Spectrom, 13, 543 (1998).
  • 13. Li M., Ni Z.M. and Rao Z., Spectrochim. Acta Part B,Si, 1381 (1998).
  • 14. Radziuk B. and Thomassen Y., J. Anal. Atom. Spectrom., 1, 397 (1992).
  • 15. Dittrich K. and Fuchs H., J. Anal. Atom. Spectrom., 5, 39 (1990).
  • 16. Kumpulainen K. and Saarela K.E., J. Anal. Atom. Spectrom.,1, 165 (1992).
  • 17. Mahmood T.M., Qiao H. and Jackson K.W., J. Anal. Atom. Spectrom., 10, 43 (1995).
  • 18. Volynsky A.B. and Krivan V., J. Anal. Atom. Spectrom., 2, 159 (1996).
  • 19. Fischer J.L,, Spectrochim. Acta Part B, 57, 525 (2002).
  • 20. Tsalev D.L., Lampugnani L., Ulivo A.D., Petrov I.I,. Georgieva R., Marcucci K. and Zamboni R., Microchem. J., 70, 103 (2001).
  • 21. Tsalev D.L., Ulivo A.D., Lampugnani L., Marco M.D. and Zamboni R., J. Anal. Atom. Spectrom., 10, 1003 (1995).
  • 22. Bermejo-Barrera P., Morenda-Pińeiro A. and Bermejo-Barrera A., Spectrochim. Acta Part B, 57, 327 (2002).
  • 23. Wysocka I.A., Bulska E., Wróbel K. and Wróbel K., Chem. Anal. (Warsaw), 48, 919 (2003).
  • 24. Sabč C R., Rubio R. and Garcia-Beltrán L., Anal. Chim. Acta, 398, 279 (1999).
  • 25. Yan X.P. and Ni Z.M.,Fresenius J. Anal. Chem.,310, 1052 (2001).
  • 26. Volynsky A.B. and Krivan V., J. Anal Atom. Spectrom., 12, 333 (1997).
  • 27. Volynsky A.B. and Wennrich R., Talanta, 59, 277 (2002).
  • 28. Tyson J.F., Sundin N.G., Hanna C.P. and McIntosh S.A., Spectrochim. Acta Part B, 52, 1773 (1997).
  • 29. Leblanc A.. J. Anal. Atom. Spectrom., 11, 1093 (1996).
  • 30. Li F., Goessler W.and Irgolic K.J., Anal. Commun., 35, 361 (1998).
  • 31. Bulska E., Liebert-Ilkowska K. and Hulanicki A., Spectrochim. Acta Part B, 53, 1057 (1998).
  • 32. Taylor A., Branch S., Halls D.J., Owen L.M.W. and White M., J. Anal. Atom. Spectrom., 14, 717 (1999).
  • 33. Bulska E. and Jędral W., J. Anal. Atom. Spectrom., 10, 49 (1995).
  • 34. Hulanicki A., Bulska E., Godlewska B, and Wrobel K., Anal. Letters, 22, 1341 (1989).
  • 35. Bulska E., Grobenski Z. and Schlemmer G., J. Anal. Atom. Spectrom., 5, 203 (1990).
  • 36. Hirano Y., Yamamura K., Oguma K. and Harada K., Anal. Sci., 17, 1295 (2001).
  • 37. Hirano Y., Yamamura K., Oguma K. and Harada K., Anal. Sci., 17, 135 (2001).
  • 38. Kopyść E., Bulska E. and Wennrich R.. Spectrochim. Acta Part B, 58, 1515 (2003).
  • 39. Piaścik M. and Bulska E., Fresenius' J. Anal. Chem., 371, 1079 (2001).
  • 40. Bulska E. and Ortner H.M., Spectrochim. Acta Part B, 56, 363 (2000).
  • 41. Bulska E., Tybusch B. and Ortner H.M., Spectrochim. Acta Part B, 56, 363 (2001).
  • 42. Robberecht H.J. and Delstra H.A.Cli.. Chim. Acta, 136, 107 (1984).