PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

HPLC separation of the mixture of tetracyclines and flumequine

Wybrane pełne teksty z tego czasopisma
Identyfikatory
Warianty tytułu
PL
Rozdzielanie mieszaniny tetracyklin i flumechiny metodą HPLC
Języki publikacji
EN
Abstrakty
EN
Tetracyclines and fluoroquinolones are used as human and veterinary antibiotics. Their extensive use as medicines and feed additives results in the appearance of their residues or metabolites in food. Therefore, it is important to develop a reliable method of detection of such residues. RP-HPLC isocratic separation of the mixture of four tetracyclines and flumequine has been proposed. The factors influencing retention of the analytes were investigated, including the content of the modifier, pH of the mobile phase, and concentration of the complexing agent. Addition of triethylamine was found to facilitate the separation. The best isocratic separation was obtained on C18 column packings with the methanol-oxalic acid mobile phase (40:60, v/v) with addition of triethylamine. pH of the aqueous phase was adjusted to 2.
PL
Tetracykliny i fluorochinolony są popularnymi antybiotykami w lecznictwie ludzi i zwierząt. Rezultatem ich powszechnego stosowania w weterynarii oraz jako dodatków do paszy jest pojawianie się w żywności niebezpiecznych dla zdrowia pozostałości tych leków oraz ich metabolitów. Istotne jest zatem opracowanie wiarygodnych metod oznaczania pozostałości antybiotyków w żywności. W niniejszej pracy przedstawiono izokratyczną metodę, rozdzielania czterech tetracyklin oraz flumechiny za pomocą metody RP-HPLC. Badano czynniki wpływające na retencję tych leków tj. zawartość modyfikatora, pH fazy ruchomej oraz stężenie czynnika kompleksującego. Stwierdzono, że dodatek trietyloaminy sprzyjał jakości rozdzielania. Najlepsze rozdzielenie czterech tetracyklin i flumechiny uzyskano przy zastosowaniu fazy C(18), oraz jako eluentu mieszaniny metanolu i kwasu szczawiowego (40:60, v/v) z dodatkiem trietyloaminy, pH fazy wodnej ustalono na 2.
Czasopismo
Rocznik
Strony
749--758
Opis fizyczny
Bibliogr. 15 poz.
Twórcy
autor
  • Department of Physical Chemistry and Physicochemical Separation Methods, University of Maria Curie-Skłodowska, M.C. Sklodowska Sq. 3, 20-031 Lublin, Poland
autor
  • Department of Physical Chemistry and Physicochemical Separation Methods, University of Maria Curie-Skłodowska, M.C. Sklodowska Sq. 3, 20-031 Lublin, Poland
Bibliografia
  • 1. Marzo A. and Dal Bo L., J. Chromatogr., 812, 17 (1998).
  • 2. Barker S.A. and Walker C.C., J. Chromatogr., 624, 195 (1992).
  • 3. Carlucci G., J. Chromatogr., 812, 343 (1998).
  • 4. Oka H., Ito Y. and Matsumoto H., J. Chromatogr., 882, 109 (2000).
  • 5. Yorke J.C. and Froc P., J. Chromatogr., 882, 63 (2000).
  • 6. Siddique I.H., Antibiotic Residues in Foods in: Food Poisoning - Handbook of Natural Toxins, [Tu T.A., Ed.], vol. 7, Marcel Dekker, New York 1992.
  • 7. Lambert H.P. and O'Grady F.W., Antibiotic and Chemotherapy, 6/E, Longman Group UK Limited, London, 1992.
  • 8. Aerts M.M.L., Hogenboom A.C. and Brinkman U.A.Th., J. Chromatogr. B, 667, 11 (1995).
  • 9. Brandsteterowa E., Kubalec P., Bovanova L., Simko P., Bednarikova A. and Machackova L., Food Res. Technol., 205, 311 (1997).
  • 10. Hernández J.A., Beltrán J.L., Compaňó R. and Prat M.D., J. Chromatogr. A, 942, 275 (2002).
  • 11. Bobbitt R.D.and Ng K.W., J. Chromatogr., 624, 195 (1992).
  • 12. Oka H., Uno K., J. Chromatogr., 298, 435 (1984).
  • 13. CRC Handbook of Chemistry and Physics, [Lide D.R., Ed.], 75th editon, CRC Press, Inc., Boca Raton 1994.
  • 14. Zurhelle G., Entwicklung und Anwedung einer automatisierten HPLC-Methode mit gekoppelter on-line Dialyse: Metabolismus, Verteilung und Elimination dreier Tetracycline bei Legehennen, Thesis, Wuppertal 2000.
  • 15. Barbosa J., Barrón D., Bergés R., Sanz-Nebot V. and Toro I.., J. Chem. Soc. Faraday Trans., 93, 1915 (1997).
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BPP1-0044-0079
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.