A simple kinetic spectrophotometric method for the determination of salbutamol in dosage forms

Wybrane pełne teksty z tego czasopisma
Identyfikatory
Warianty tytułu
PL
Prosta kinetyczno-spektrofotometryczna metoda oznaczania salbutamolu w preparatach farmaceutycznych
Języki publikacji
EN
Abstrakty
EN
A simple and sensitive kinetic method for the determination of salbutamol in pharmaceutical preparations has been developed. The method is based upon the kinetic determination of the oxidation product of the drug with alkaline potassium permanganate at the room temperature for the fixed time of 30 min. The absorbance of the coloured manganate group compound was measured at 610 nm. The absorbance changed linearly with the concentration in the range of 2-10 žg mL-1 (r = 0.9995) and the minimum detectability (S/N = 2) was 0.2 žg mL-1 (3.47 × 10-7 mol L-1). Different experimental parameters affecting the development and stability of the colour have been carefully studied and optimised. Determination of salbutamol by the fixed-concentration and rate-constant methods is also feasible using the appropriate calibration equations, yet the fixed-time method has proved to be more advantageous. It was further applied to the determination of salbutamol in pharmaceutical formulations. The results were in good agreement with those obtained with the reference method. The reaction pathway has been proposed as well.
PL
Opracowano prostą i czułą kinetyczną metodę oznaczania salbutamolu w preparatach farmaceutycznych. Metoda jest oparta na kinetycznym oznaczaniu produktu utleniania leku za pomocą zasadowego roztworu nadmanganianu potasu w temperaturze pokojowej w ustalonym czasie 30 min. Absorbancję barwnego rodnika mań gani anowego mierzono przy długości fali 610 nm. Wykres: absorbancja - stężenie był prostoliniowy w zakresie stążeń 2-10 fig mL-1 (r = 0,9995) z granicą detekcji (S/N = 2) równą 0,2 ug ml/1 (3,47 x10 (-7) mol L(-1). Zbadano i zoptymalizowano różne parametry doświadczalne wpływające na rozwinięcie i trwałość barwy. Salbutamol można oznaczać posługując się wyprowadzonymi równaniami kali bracyjnymi zarówno dla metody ustalonego stężenia jak i stałej szybkości reakcji, jednał metoda ustalonego stężenia jest korzystniejsza. Zaproponowaną metodę zastosowano di oznaczania salbutamolu w preparatach farmaceutycznych. Wyniki były w dobrej zgodność z wynikami uzyskanymi za pomocą metody odniesienia. Zaproponowano schema prawdopodobnego przebiegu reakcji.
Czasopismo
Rocznik
Strony
587--599
Opis fizyczny
Bibliogr. 34 poz.
Twórcy
autor
  • Department of Analytical Chemistry, Faculty of Pharmacy, University of Mansoura, 35516, Mansoura, Egypt
autor
  • Department of Pharmaceutical Chemistry, Faculty of Pharmacy, University of King Saud, P.O.Box 2457, Riyadh, 11451, Saudi Arabia
autor
  • Department of Analytical Chemistry, Faculty of Pharmacy, University of Mansoura, 35516, Mansoura, Egypt
Bibliografia
  • 1. Parfitt K., The Complete Drug Reference, 32rd edn, Martindale, The Pharmaceutical Press, Massachusetts 1999, p. 758.
  • 2. The International Pharmacopoeia, Vol. 3 3rd edn., WHO, Geneva 1988, p. 284.
  • 3. Bhatt K., Shah S.A. and Pandya S.S., Indian Drugs, 36, 524 (1999).
  • 4. Nour-El-Dien F.A., Spectrosc. Lett., 33, 347 (2000).
  • 5. Bhatia N.M., Jain D.K. and Trivedi P., Indian Drugs, 35, 566 (1998).
  • 6. Singhvi I. and Chaturvedi S.C., Indian Drugs, 35, 421 (1998).
  • 7. Sanghavi N.M. and Vyas J.J., Indian Drugs, 34, 463 (1997).
  • 8. Bakry R.S., Razak O.A., El-Walily A.F.M . and Belal S.F., J. Pharm. Biomed. Anal., 14, 357 (1996).
  • 9. Bakry R.S., El-Walily A.F. and Belal S.F., Anal. Lett., 28, 2503 (1995).
  • 10. El-Enany N., Belal F. and Rizk M., Chem. Anal. (Warsaw), 49, (2004).
  • 11. Ventura R., Damasceno L., Farre M., Cardoso J. and Segura J., Anal.Chim. Acta, 418, 79 (2000).
  • 12. Black S.B. and Hansson R.C., J. Anal. Toxicol., 23, 113 (1999).
  • 13. Needham R.S. and Brown P.R., J. Pharm. Biomed. Anal., 23, 597 (2000).
  • 14. Loss J.R., Orzechowski R.F. and Hock R.S., J. Biomed. Chromatogr., 14, 1 (2000).
  • 15. Wang J.Q., Yu L. and Dai H., Yaow-Fenxi-Zazhi, 19, 388 (1999). Anal. Abstr., 62, 4626 (2000).
  • 16. Schmeer K., Sauter T. and Schmid J., J. Chromatogr. A., 777, 67 (1997).
  • 17. Sagar K.A., Hua C., Kelly M.T. and Smyth M.R., Electroanal., 4, 481 (1992).
  • 18. Koppenhoefer B., Jakob A., Zhu X.F. and Lin B.C., J. Resolut. Chromatogr., 23, 413 (2000).
  • 19. Gotti R., Furlanetto S., Andrisano V., Cavrini V. and Pinzauti S., J. Chromatogr. A., 875, 411 (2000).
  • 20. Gucek M., Vreeken R.J. and Verheij E.R., Rapid. Commun. Mass. Spectrom., 13, 612 (1999).
  • 21. Boyd D., Barreira-Rodriquez J.R., Miranda-Ordieres A.J., Tunon-Blanco P. and Smyth M.R., Analyst, 119, 1979 (1994).
  • 22. Sagar K.A., Smyth M.R. and Munden R., J. Pharm. Biomed. Anal.,11, 533 (1993).
  • 23. Hua C., Sugar K.A., Mclaughlin K., Jorge M., Meaney M.P. and Smyth M.R., Analyst, 116, 1117 (1991).
  • 24. Sun X.X. and Ding H.L., Fenxi. Shiyanshi, 18, 75 (1999). Anal. Abstr., 62, 26148 (2000).
  • 25. Barnett N.W., Hindson B.J. and Lewis S.W., Anal. Chim. Acta, 384, 151 (1999).
  • 26. Burns T.D., Chimpalee N., Chimpalee D. and Leiwongcharoen K., Anal. Chim. Acta, 260, 65 (1992).
  • 27. Nausch I. and Galley K., Arch. Lebensmittelhyg, 50, 104 (1999).
  • 28. Rizk M., Belal F., Ibrahim F., Ahmed S.and El-Enany N., Sci. Pharm., 68, 173 (2000).
  • 29. Rizk M., Belal F., Ibrahim F., Ahmed S. and El-Enany N., J. Pharm. Biomed. Anal., 23, 503 (2000).
  • 30. El-Enany N., Belal F. and Rizk M., IL Farmaco, 57, 641 (2002).
  • 31. Espinosa-Mansilla A., Acedovalenzuela M.I., Salinas F. and Canada F., Anal. Chim. Acta, 376, 365 (1998).
  • 32. Kopanica M. and Stara V., Kinetic Methods in Chemical Analysis, Elsevier, Amsterdam 1983.
  • 33. Caulcut R. and Boddy R., Statistics for Analytical Chemists, Chapman and Hill, London 1983.
  • 34. Rose J., Advanced Physico-Chemical Experiments, Pitman, London 1964, 67.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BPP1-0044-0066
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.