HPLC analysis of plasminogen and tissue plasminogen activator

Wybrane pełne teksty z tego czasopisma
Identyfikatory
Warianty tytułu
PL
Analiza plazminogenu i tkankowego aktywatora plazminogenu metodą HPLC
Języki publikacji
EN
Abstrakty
EN
A chromatographic system for the simultaneous determination of plasminogen and tissue plasminogen activator has been developed. Plasminogen and tissue plasminogen activator could be determined qualitatively and quantitatively within 30 min applying HPLC (C(18) 5 (um, 250 x 4 mm column) with DAD detector, and gradient elution with the mobile phase comprising 0.1% trifluoroacetic acid (TFA) in water and 0.085% TFA in acetonitrile, at the flow rate of 0.8 mL min(-1) or 1.0 mL min(-1). The following retention times for plasminogen and tissue plasminogen activator in human plasma were found: 23.31 min and 23.95 min, respectively.
PL
Opracowano chromatograficzną metodę jednoczesnego oznaczania plazminogenu i tkankowego aktywatora pla/minogenu (t-PA). Zastosowanie HPLC z detektorem DAD, kolumną C(18) 5 um), 250 x 4 mm, gradientowym przepływem fazy ruchomej, będącej mieszaniną 0. 1 % kwasu trifluorooctowego (TFA) w wodzie i 0.085% TFA w acetonitrylu, przy natężeniu przepływu 0.8 mL min'1 lub 1.0 mL min(-1), pozwala na jakościowe i ilościowe oznaczenie plazminogenu i t-PA w czasie 30 min. Czasy retencji plazminogenu i tkankowego aktywatora plazminogenu w osoczu ludzkim wynosiły odpowiednio: 23.31 min i 23.95 min.
Czasopismo
Rocznik
Strony
621--626
Opis fizyczny
Bibliogr. 14 poz.
Twórcy
  • Silesian Centre of Heart Disease, Medical University of Katowice, Department of Pediatric Cardiology, ul. Szpitalna 2, 41-800 Zabrze, Poland
autor
  • Department of Analytical and General Chemistry, Silesian University of Technology, ul. Strzody 7, 44-100 Gliwice, Poland
  • Department of Analytical and General Chemistry, Silesian University of Technology, ul. Strzody 7, 44-100 Gliwice, Poland
autor
  • Department of Analytical and General Chemistry, Silesian University of Technology, ul. Strzody 7, 44-100 Gliwice, Poland
Bibliografia
  • 1. Chmielewska J. and Wiman B., Clin. Chem., 32, 482 (1986).
  • 2. Matsuo O., Kato K., Matsuo C. and Matsuo T., Anal. Biochem., 135, 58 (1983).
  • 3. Pietrucha T. and Cierniewski C.S., Post. Biochem., 3, 33 (1991).
  • 4. Kuo B.-S. and Bjornsson T.D., Anal. Biochem., 209, 70 (1993).
  • 5. O'Reilly M.S., Holmgren L., Shing Y., Chen C., Rosenthal R.A., Moses M., Lane W.S., Cao Y., Sage E.H. and Folkman J., Cell, 79, 315 (1994).
  • 6. Wang H., Prorok M., Bretthauer R.K. and Castellino F.J., Biochem., 36, 8100 (1997).
  • 7. Fleming C.M., Kowalski B.R., Apffel A. and Hancock W.S., J. Chromatogr. A, 849, 71 (1999).
  • 8. Egelund R., Rodenburg K.W., Andreasen P.A., Rasmussen M.S., Guldberg R.E. and Petersen T.E., Biochem., 37, 6375 (1998).
  • 9. Upshall A., Kumar A.A., Bailey M.C., Parker M.D., Favreau M.A., Lewison K.P., Joseph M.L., Maraganore J.M. and McKnight G.L., Bio/Technology, 5, 1301 (1987).
  • 10. Shikata Y., Kuwada M., Hayashi Y., Hashimoto A., Koide A. and Asakawa N., Anal. Chim. Acta, 365, 241 (1998)
  • 11. Mock K., Hail M., Mylchreest I., Zhou J., Johnson K. and Jardine I., J. Chromatogr., 646, 169 (1993).
  • 12. Apffel A., Chakel J.A., Hancock W.S., Sauders C., Timkulu T.M. and Pungor Jr. E., J. Chromatogr. A., 750, 35 (1996).
  • 13. Taverna M., Baillet A., Werner R. and Bayloco-Ferrier D., J. Chromatogr., 558, 105 (1991).
  • 14. Wu S.L., Anal. Biochem., 253, 85 (1997).
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BPP1-0037-0037
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.