Determination of metals in drinking, surface and waste water by XRF spectrometry after preconcentration of the sample on the ion-exchange filter

Wybrane pełne teksty z tego czasopisma
Identyfikatory
Warianty tytułu
PL
Oznaczanie metali w pitnej i powierzchniowej wodzie oraz w ściekach za pomocą spektrometrii XRF, po wstępnym zagęszczeniu próbki na filtrze jonowymiennym
Języki publikacji
EN
Abstrakty
EN
The paper describes a fast and cheap method for determination of Zn, Ni, Cr, Fe, V, Pb, and Co content in water by the means of wavelength dispersive X-ray fluorescence (WD XRF) spectrometry after preconcentration of the sample on the ion-exchange filter. The preconcentration was achieved on filters prepared from the Oxin ion-exchanger with 8-hydroxyquinoline functional groups bound to the fibrous cellulose. The sorption conditions for Zr were optimized, which subsequently served as the correction standard. Detection limits (in |ig) for maximum volume (500 mL) of the preconcentrated sample were as follows: DL(ZN) = 1.049, DL(Ni) = 0.867, DL(Cr) = 0.281, DLKc = 0.512, DLV = 0.549, DL(Pb) = 0.619, DL(CO) = 0.453. The method of preconcentration is simple and can be realized in mobile laboratories with consecutive laboratory WDXRF analysis.
PL
Opisano szybką i tanią metodę oznaczania zawartości Zn, Ni, Cr, Fe, V, Pb i Co w wodzie za pomocą fluorescencji rentgenowskiej z dyspersją fali (WD XRF) po wstępnym zatężeniu próbki na filtrze jonowymiennym. Do wstępnego zatężania użyto filtrów przygotwanych z wymieniacza typu Oxin zawierającego grupy funkcyjne 8-hydroksychinoliny związane z włóknistą celulozą. Ustalono optymalne warunki dla sorpcji Zr, który był następnie używany jako wskaźnik korekcyjny. Wyznaczono następujące granice detekcji (w u.g) dla maksymalnej objętości zatężanej próbki 500 mL: DL(ZN) = 1.049, DL(Ni) = 0.867, DL(Cr) = 0.281, DLFe = 0.512, DL(V) = 0.549, DL(pb) = 0.619, DL(C0) = 0.453. Metoda zatężania jest prosta i może być wykonywana w przenośnym laboratorium, po czym próbki są poddawane analizie przy użyciu WD XRF.
Czasopismo
Rocznik
Strony
55--64
Opis fizyczny
Bibliogr. 18 poz.
Twórcy
autor
  • University of Pardubice, Faculty of Chemical Technology, Laboratory of Atomic Spectroscopy, Cs. Legii 565, 532 10 Pardubice, Czech Republic
  • University of Pardubice, Faculty of Chemical Technology, Laboratory of Atomic Spectroscopy, Cs. Legii 565, 532 10 Pardubice, Czech Republic
  • University of Pardubice, Faculty of Chemical Technology, Laboratory of Atomic Spectroscopy, Cs. Legii 565, 532 10 Pardubice, Czech Republic
Bibliografia
  • 1. Potts P.J., Ellis A.T., Holmes M., Kregsamer P., Streli Ch, West M. and Wobrauschek P., J. Anal. At. Spectrom., 15, 1417 (2000).
  • 2. West N.G., Trends Anal. Chem., 3, 199 (1984).
  • 3. Czech state standard ČSN 75 71 111.
  • 4. X-Ray Spectrometry, Proceedings from training held on 11-13.6.1997 in Komorní Lhotka, 2 THETA 1997, p.126, (in Czech).
  • 5. Luke C.L., Anal. Chim. Acta, 41, 237 (1968).
  • 6. Cole P.C., Eckert J.M. and Williams K.L., Anal. Chim. Acta, 153, 61 (1983).
  • 7. Sanna L., Peräniemi S. and Ahlgrén M., Analyst, 124, 1105 (1999).
  • 8. De Vito I.E., Olsina R.A. and Masi A.N., Fresenius J.Anal. Chem., 368, 396 (2000).
  • 9. De Vito I.E., Olsina R.A. and Masi A.N., J. Anal. At. Spectrom., 16, 275 (2001).
  • 10. Menendez-Alonso E., Hill S.J., Foulkes J.S. and Crighton J.S., J. Anal. At. Spectrom., 14, 187 (1999).
  • 11. Clanet F. and Deloncle R., Anal. Chim. Acta, 117, 343 (1980).
  • 12. Lieser K.H., Roeber H.M. and Burba P., Fresenius J. Anal. Chem., 284, 361 (1977).
  • 13. Kingston H. and Pella P.A., Anal. Chem., 53, 223 (1981).
  • 14. Campbell W.J., Spano E.F. and Green T.E., Anal. Chem., 38, 987 (1966).
  • 15. Smits J.A. and Van Grieken R.E., Anal. Chem., 52, 1479 (1980).
  • 16. McComb M.E. and Gesser H.D., Anal. Chim. Acta, 341, 229 (1997).
  • 17. McComb M.E. and Gesser H.D., Talanta, 49, 869 (1999).
  • 18. Pytela O., Chemometrics for Organic Chemists, University of Pardubice, 2000, ISBN 80-7194-309-6. (in Czech).
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BPP1-0036-0084
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.