PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

Extraction of alcohols into a xylene drop

Wybrane pełne teksty z tego czasopisma
Identyfikatory
Warianty tytułu
PL
Ekstrakcja alkoholi do kropli ksylenu
Języki publikacji
EN
Abstrakty
EN
A headspace microextraction into a single drop for the determination of alcohols in aqueous solutions is proposed. A drop of o-xylene containing butanone-2 as an internal standard is used for the extraction. The analytes are extracted by suspending a 3 U.L extracting drop directly from the tip of a microsyringe fixed above the extraction vial such that the needle passes the septum and the needle tip appears above the surface of the solution. After the extraction is finished the drop is retracted back into the needle and injected directly into the GC instrument. The influence of the experimental conditions — sampling time, sampling temperature, stirring rate and ionic strength of the solution — on the extraction efficiency was investigated. The linear range and the precision are examined. The headspace single drop microextraction is applied for the analysis of beer.
PL
Zaproponowano metodę mikroekstrakcji do kropli z nadprzestrzeni do oznaczania zawartości alkoholi w roztworach wodnych. 3 (J.L kroplę o-ksylenu, zawierającą butanon-2 jako wewnętrzny standard, wyciskano z igły mikrowtryskiwacza tak aby kropla zawisła nad ekstraho-wanym roztworem. Po ukończeniu ekstrakcji kroplę wciągano z powrotem do igły i wtryski-wano bezpośrednio do chromatografu gazowego. Zbadano wpływ warunków przeprowadzania ekstrakcji na jej skuteczność: czas trwania ekstrakcji, temperaturę ekstrakcji, szybkość mieszania i moc jonową roztworu. Ustalono zakres prostoliniowości i dokładność oznaczania. Mikroekstrakcję do kropli z nadprzestrzeni zastosowano do analizy piwa.
Czasopismo
Rocznik
Strony
935--944
Opis fizyczny
Bibliogr. 13 poz.
Twórcy
  • Department of Analytical and Environmental Chemistry, Vilnius University, Naugarduko 24, LT-2006 Vilnius, Lithuania
autor
  • Department of Analytical and Environmental Chemistry, Vilnius University, Naugarduko 24, LT-2006 Vilnius, Lithuania
  • Department of Analytical and Environmental Chemistry, Vilnius University, Naugarduko 24, LT-2006 Vilnius, Lithuania
  • Department of Analytical and Environmental Chemistry, Vilnius University, Naugarduko 24, LT-2006 Vilnius, Lithuania
Bibliografia
  • 1. Jeannot M.A. and Cantwell F.F., Anal. Chem., 68, 2236 (1996).
  • 2. de Jager L.S. and Andrews A.R.J., Analyst, 125, 1943 (2000).
  • 3. Ligor T., and Buszewski B., Chromatographia, 51, S279 (2000).
  • 4. Jeannot M.A. and Cantwell F.F., Anal. Chem., 69, 235 (1997).
  • 5. Jeannot M.A. and Cantwell F.F., Anal. Chem., 69, 2935 (1997).
  • 6. Wang Y. , Kwok Y.Ch. , He Y. and Lee H.K., Anal. Chem., 70, 4610 (1998).
  • 7. Belardi R.P. and Pawliszyn J., Water Pollut. Res. J. Canada, 24, 179 (1989).
  • 8. Liu S. and Dasgupta P.K., Anal. Chem., 67, 2042 (1995).
  • 9. Gorecki T. , Martos P. and Pawliszyn J., Anal. Chem., 70, 19 (1998).
  • 10. Matisova E., Sedlakova J. and Slezackova M., J. High Resol. Chromatogr., 22, 109 (1999).
  • 11. Tankeviciute A., Kazlauskas R. and Vickackaite V., Analyst, 126, 1674 (2001).
  • 12. Lord H. and Pawliszyn J., J. Chromatogr. A, 902, 17 (2000).
  • 13. Psillakis E. and Kalogerakis N., J. Chromatogr. A, 907, 211 (2001).
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BPP1-0031-0025