PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

Long-term monitoring of organic pollutants in water - application of passive dosimetry

Wybrane pełne teksty z tego czasopisma
Identyfikatory
Warianty tytułu
PL
Długotrwały monitoring zanieczyszczeń organicznych w wodzie - zastosowanie dozymetrii pasywnej
Języki publikacji
EN
Abstrakty
EN
Sampling is the first and the most important step of each analysis procedure. It is also the most important because is performed in situ. Presently two groups of techniques of sampling for investigation and monitoring of aqueous environments are usually applied in analytical practice: grab sampling of water; sampling with simultaneous izolation and preconcentration of analytes on the basis of forced flow of liquid sample through a proper trap, for example through a tube with a sorbent. During last years, a good deal of papers appeared proposing a new approach to sampling of liquid samples containing organic analytes. It concerns the application of passive dosimetry, the technique commonly used in air control and monitoring. The paper presents the basic types of passive devices such as: SPM (semipermeable membranes), SPMD (semipermeable membrane devices), PISCES (passive in situ concentration/extraction sampler), SLM (supported liquid membranes). The particular attention is focused on advantages of semipermeable membrane devices SPMD technique.
PL
Pobieranie próbek jest pierwszym i najważniejszym a jednocześnie i najtrudniejszym (bo wykonywanym in situ) etapem każdej procedury analitycznej. W chwili obecnej w praktyce analitycznej znajdują zastosowanie przede wszystkim dwie grupy technik pobierania próbek w zakresie badania i monitoringu środowiska wodnego: pobieranie próbek wody o dużej objętości; pobieranie próbek z jednoczesną izolacją i wzbogacaniem analitów, wykorzystując dynamiczny przepływ ciekłej próbki przez odpowiednio dobrane medium sorpcyjne, np. rurkę wypełnioną stałym sorbentem. W ciągu ostatnich kilku lat pojawiło się sporo prac na temat innego podejścia do zagadnienia pobierania próbek analitów organicznych z badanego medium ciekłego. Dotyczą one wykorzystania dozymetrii pasywnej, techniki, która jest już powszechnie wykorzystywana w zakresie kontroli i monitoringu powietrza. W pracy przedstawiono podstawowe typy urządzeń pasywnych, do pobierania próbek analitów z ciekłego medium takie jak SPM; (semipermeable membranę), SPMD (semipermeable membranę devices), PISCES (passive in situ concentration/extraction sampler), SLM (supported liquid membranes). Szczególną uwagę zwrócono na zalety i wykorzystanie urządzenia z półprzepusz-czalnych membran SPMD.
Czasopismo
Rocznik
Strony
645--657
Opis fizyczny
Bibliogr. 48 poz.
Twórcy
  • Department of Analytical Chemistry, Chemical Faculty, Technical University of Gdańsk, 11/12 Narutowicza Str., 80-952 Gdańsk, Poland
autor
  • Department of Analytical Chemistry, Chemical Faculty, Technical University of Gdańsk, 11/12 Narutowicza Str., 80-952 Gdańsk, Poland
  • Department of Analytical Chemistry, Chemical Faculty, Technical University of Gdańsk, 11/12 Narutowicza Str., 80-952 Gdańsk, Poland
Bibliografia
  • 1. D'Adamo R., Pelosi S., Trotta P. and Sansone G., Mar. Chem., 56, 45 (1997).
  • 2. Fries G.F., Organic contaminants in terrestrial foods chains in: Organic contaminants in the environment. Environmental pathways and effects, [Jones K.C., Ed.], Elsevier, London, 1991, p. 207-236.
  • 3. Koester C.J. and Clement R.E., Crit. Rev. Anal. Chem., 24, 263 (1993).
  • 4. Majors R., LC.GC Internat., 10, 93 (1997).
  • 5. Soniassy R., Sandra P. and Schlett C., Water Analysis, Hewlett-Packard Company 1994.
  • 6. Eisert R. and Pawliszyn J., Crit. Rev. Anal. Chem., 27, 103 (1997).
  • 7. Fick A., Ann. Phys. Chem., 40, 55 (1955).
  • 8. Kozdroń-Zabiegała B., Namieśnik J. and Przyjazny A., Indoor Environ., 4, 189 (1995).
  • 9. Cao Xu-L. and Hewitt C.N., Environ. Technol., 12, 1055 (1991).
  • 10. Huckins J.N., Tubergen M.W., Lebo J.A., Gale R.W. and Schwartz T.R., JAOAC, 73, 290 (1990).
  • 11. Johnson G.D., Environ. Sci. Technol., 25, 1897 (1991).
  • 12. Peterson S.M., Apte S.C., Batley G.E. and Coade G., Chem. Spec. Bioavail., 7, 83 (1995).
  • 13. Södergren A., Environ. Sci. Technol., 21, 855 (1987).
  • 14. Södergren A., Ecotoxicol. Environ. Saf., 19, 143 (1990).
  • 15. DiGlano F.A., Elliot D. and Leith D., Environ. Sci. Technol., 22, 1365 (1988).
  • 16. Grathwohl P. and Schiedek T., Passive samplers as a long-term monitoring system for hydrophobic organic contaminants, in: Field screening Europe, [Gottlieb J., Ed.], Kluwer Academic Publisher, 1997, 33-36.
  • 17. Huckins J.N., Manuweera G.K., Petty J.D., Mackay D. and Lebo J.A., Environ. Sci. Technol., 27, 2489 (1993).
  • 18. Huckins J.N., Tubergen M.W. and Manuweera G.K., Chemosphere, 20, 533 (1990).
  • 19. Bennett E.R., Metcalfe T.L. and Metcalfe C.D., Chemosphere, 33, 363 (1996).
  • 20. Huckins J.N., Manuweera G.K., Petty J.D., Mackay D. and Lebo J.A., Environ. Sci. Technol., 27, 2489 (1993).
  • 21. Bergqvist A., Strandberg B., Ekelund R., Rappe C. and Granmo A., Environ. Sci. Technol., 32, 3887 (1998).
  • 22. Litten S., Mead B. and Hassett J., Environ. Toxicol. Chent., 12, 639 (1993).
  • 23. Megersa N. and Jonsson J.A., Analyst, 123, 225 (1998).
  • 24. Jonsson J.A. and Mathiasson L., Trends Anal. Chem., 11, 106 (1992).
  • 25. Jol J., Jonsson J.A. and Mathiasson L., Trends Anal. Chem., 18, 318 (1999).
  • 26. US patent, 5 098 573.
  • 27. Gale R.W., Huckins J.N., Petty J.D., Peterman P.H., Williams L.L., Morse D., Schwartz T.R. and Tillitt D.E., Environ. Sci. Technol., 31, 178 (1997).
  • 28. Prest F., Jarman W.M., Burns S.A., Weismuller T., Martin M. and Huckins J.N., Chemosphere, 25, 1811 (1992).
  • 29. Peven C.S., Uhler A.D. and Querzoli F.J., Environ. Sci. Technol., 15, 144 (1996).
  • 30. Lebo J.A., Zajicek J.L., Huckins J.N., Petty J.D. and Peterman P.H., Chemosphere, 25, 697 (1992).
  • 31. Lebo J.A., Zajicek J.L., Orazio C.E., Petty J.D., Huckins J.N. and Douglas E.H., Polycylic. Arom. Compd., 8, 53 (1996).
  • 32. Prest H.F., Jacobson L.A. and Wilson M., Chemosphere, 12, 3047 (1997).
  • 33. Moring J.B. and Rose D.R., Chemosphere, 34, 551 (1996).
  • 34. De La Torre A.I., Fernandez C., Tarazona J.V. and Munoz M.J., Chemosphere, 31, 2727 (1995).
  • 35. Ellis G.S., Huckins J.N., Rostad C.E., Schmitt C.J., Petty J.D. and MacCarthy P., Environ. Toxicol. Chem., 14, 1875 (1995).
  • 36. Petty J.D., Huckins J.N., Martin D.B. and Adornato T.G., Chemosphere, 30, 1891 (1995).
  • 37. Petty J.D., Huckins J.N., Orazio C.E., Lebo J.A., Poulton B.C., Gale R.W., Charbouneau C.S. and Kaiser E.M., Environ. Sci. Technol., 29, 2561 (1995).
  • 38. Prest H.F., Jacobson L.A. and Huckins J.N., Chemosphere, 30, 1351 (1995).
  • 39. Rohr A.C., Hall E.R. and Hall K.J., Water Qual. Res. J. Canada, 31, 85 (1996).
  • 40. Herve S., Paukku R., Paasivirta J., Heinonen P. and Södergren A., Chemosphere, 22, 997 (1991).
  • 41. Lebo J.A., Gale R.W., Petty J.D., Tillit D.E., Huckins J.N., Meadows J.C., Orazio C.E., Echols K.R. and Schroeder D.J., Environ. Sci. Technol., 29, 2886 (1995).
  • 42. Rantalainen A., Ikonomou M.G. and Rogers I.H., Chemosphere, 37, 1119 (1998).
  • 43. Kukkonen J., Rantalainen A.L., Mikkelson P., Lyytikainen M., Hamalainen H. and Paasivirta J., Ecotoxico., 39, 5 (1998).
  • 44. Chambers D.B., J. A1n. Water Resour. Assoc., 35, 143 (1999).
  • 45. Bergqvist P.-A., Strandberg B. and Rappe C., Chemosphere, 38, 933 (1999).
  • 46. Bergqvist P.-A., Strandberg B. and Rappe C., Proc. of Analytical Division Symposium of the RSC's. Annual Chemical Congress, April 5-8, October 1993, vol. 30.
  • 47. Strandberg B., Bergqvist P.-A. and Rappe C., Anal. Chem., 70, 526 (1998).
  • 48. Strandberg B., Wogman N., Bergqvist P.-A., Haglund P. and Rappe C., Environ. Sci. Technol., 31, 2960-2965 (1997).
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BPP1-0017-0058
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.