PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

Application of the interdigitated array microelectrodes in trace determination of selenium in water samples

Wybrane pełne teksty z tego czasopisma
Identyfikatory
Warianty tytułu
PL
Zastosowanie przemiennie polaryzowanych pasm mikroelektrod do oznaczania śladów selenu w próbkach wody
Języki publikacji
EN
Abstrakty
EN
A method applying an interdigitated array (IDA) microelectrode is proposed for the trace determination of species for which stripping analysis is disabled by the formation of multiple peaks during electrochemical dissolution of the deposit. Independent polarization of both (IDA) microelectrode arrays was applied. The time dependence of the reduction current of the deposit dissolved in the diffusion layer of the IDA microelectrode is used for the evaluation the concentration. As the reductiol1 current is registered at the segment polarized by a constant potential, it is practically free of the undesired capacity component. A method of multiple standart additions was used for the quantification. The method was tested using synthetic sample containg Se at the trace level required by the Slovak Republic regulatiol1s, and was next used for the determination of Se in tap and environmental water.
PL
Opracowano metodę oznaczania selenu w próbkach wód wykorzystując wielopasmowe mikroelektrody o naprzemierzennie polaryzowanych pasmach. Uprzednio zatężony selen utleniono na jednej grupie mikroelektrod pasmowych. Drugą grupę mikroelektrod polaryzowano takim stałym potencjałem, aby utleniony selen został zredukowany. Stężenie selenu obliczono analizując zależność prądu redukcji od czasu. Opracowaną metodę testowano na próbkach syntetycznych i zastosowano do oznaczenia selenu w wodzie z kranu i w wodzie środowiskowej .
Czasopismo
Rocznik
Strony
1025--1032
Opis fizyczny
Bibliogr. 12 poz.
Twórcy
autor
  • Department of Analytical Chemistry, Slovak Technical University, Redlinského 9, SK - 812 37 Bratislava, Slovak Republic
autor
  • Department of Analytical Chemistry, Slovak Technical University, Redlinského 9, SK - 812 37 Bratislava, Slovak Republic
autor
  • Department of Analytical Chemistry, Slovak Technical University, Redlinského 9, SK - 812 37 Bratislava, Slovak Republic
Bibliografia
  • 1. Kissinger P.T. and Heinemann W.R., Laboratory Techniques in Electroanalytical Chemistry, Marcel Dekker Inc., New York 1984.
  • 2. Wang J., Stripping Analysis, Deerfield Beach Inc., Florida VCH Publishers, 1985.
  • 3. Rievaj M. and Bustin D., Analyst, 117, 1471 (1992).
  • 4. Rievaj M., Mesároš Š. and Bustin D., An. Quim., 90, 209 (1994).
  • 5. Takahashi M., Morita M., Niwa O. and Tabei H., J. Electroanal. Chem., 335, 253 (1995).
  • 6. Bustin D., Mesároš Š., TomPík P., Rievaj M. and Tvarožek V., Anal. Chim. Acta, 305, 121 (1995).
  • 7. Undervood E.J., Trace Elements in Human and Animal Nutrition, Academic Press, New York 1971.
  • 8. Hashimoto Y., Hwang J.Y. and Yanagisawa S., Environ. Sci. Technol., 4, 157 (1970).
  • 9. Slovak Republic regulation for pollutants content in surface water STN 757 221.
  • 10. Slovak Republic regulation for pollutants content in tap water STN 757 111.
  • 11. Adeloju S.B., Bond A.M. and Hughes H.C., Anal. Chim. Acta, 148, 59 (1983).
  • 12. Andrews R.W. and Johnson D.C., Anal. Chem., 47, 294 (1975).
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BPP1-0012-0036
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.