Studies were made on applicability of badge permeation passive samplers with polyet-hylene semipermeable membranes for isolation and enrichment of organic analytes in indoor air quality monitoring. The effect of storage at -18°C and at approx. 20°C was evaluated. The mass changes of analytes adsorbed on active carbon in a sampler during three week storage at room temperature were not statistically significant. At a tempera-ture of -18°C permissible storage time can be extended to four weeks. Storage of the capped samplers ready for sampling (shelf life) had no noticeable effects on analytical results of benzene, toluene, butyl acetate, and ethylbenzene.
PL
W pracy przedstawiono wyniki badań nad określeniem przydatności dozymetru pasyw-nego typu permeacyjnego, o budowie pudełkowej, z półprzepuszczalną membranąpolietylenową, jako urządzenia wykorzystywanego na etapie izolacji i wzbogacania analitów z próbek powietrza do monitorowaniajakości powietrza wewnętrznego. Zakres wykonanych prac obejmował: określenie wpływu przechowywania dozymetrów w temperaturze pokojowej (ok. 20°C) i w temperaturze (-18°C) po zakończeniu ekspozy-cji, na zmianę masy zaadsorbowanych analitów oraz określenie wpływu tzw. "czasu życia dozymetrów na półce" na wyniki oznaczeń analitycznych. Na podstawie przepro-wadzonych badań stwierdzono, iż przechowywanie dozymetrów permeacyjnych po zakończeniu ekspozycji przez 3 tygodnie w temperaturze pokojowej nie powoduje statystycznie istotnych zmian masy anaIitów zaadsorbowanych na złożu sorpcyjnym (węgiel aktywny), natomiast w przypadku przechowywania dozymetrów w temperatu-rze -18°C dopuszczalny czas przechowywania można wydłużyć do czterech tygodni. Stwierdzono także, że przechowywanie zamkniętych, wypełnionych sorbentem dozy-metrów przez okres 2 miesięcy przed rozpoczęciem ekspozycji, nie wywiera mierzaI-nego wpływu na wyniki oznaczeń końcowych. Powyższe parametry użytkowe dozymetrów pasywnych wyznaczono dla wybranych lotnych związków organicznych tj. benzenu, toluenu, octanu butylu, etylobenzenu.
Czasopismo
Rocznik
Strony
215--222
Opis fizyczny
Bibliogr. 14 poz.
Twórcy
  • Department of Analytical Chemistry, Chemical Faculty, Technical University of Gdańsk, 11/12 Narutowicza Str., 80-952 Gdańsk, Poland
autor
  • Department of Analytical Chemistry, Chemical Faculty, Technical University of Gdańsk, 11/12 Narutowicza Str., 80-952 Gdańsk, Poland
autor
  • Department of Analytical Chemistry, Chemical Faculty, Technical University of Gdańsk, 11/12 Narutowicza Str., 80-952 Gdańsk, Poland
  • Department of Analytical Chemistry, Chemical Faculty, Technical University of Gdańsk, 11/12 Narutowicza Str., 80-952 Gdańsk, Poland
Bibliografia
  • 1. Kozdroń-Zabiegała B., Przyjazny A. and Namieśnik J., Indoor Environ., 4, 189 (1995).
  • 2. Namieśnik J., Zygmunt B. and Kozdroń-Zabiegała B., Pol. J. Environ. Stud., 3, 5 (1994).
  • 3. Health and Safety Executive, Methods for the Determination of hazardous substances. Protocol for assessing the performance of a diffusive sampler, MDHS 27. London, Health and Safety Executive, 1983.
  • 4. Health and Safety Executive, Methods for the determination of hazardous substances. Protocol for assessing the performance of a diffusive sampler, MDHS 27. London, Health and Safety Executive, 1987.
  • 5. Health and Safety Executive, Methods for the Determination of hazardous substances. Analytical quality in workplace air monitoring, MDSH 71. London HSE/OMHL, 1991.
  • 6. Health and Safety Executive, Hydrocarbons in air. Diffusive method using thermal desorption and gas chromatography. Methods for determination of hazardous substances, MDHS 66. London, HSE, 1989.
  • 7. Health and Safety Executive, Styrene in air. Hydrocarbons in air. Laboratory methods using porous polymer diffusive samplers, thermal desorption and gas chromatography. Methods for determination of hazardous substances, MDHS 43. London, HSE, 1985.
  • 8. Hangartner M., Diffusive sampling as an alternative approach for developing countries, World Congress on Air Pollution in Developing Countries, Costa Rica, September 1996.
  • 9. Hall G.L., Mourer C.R. and Shibamoto T., J. Agric. Food Chem., 45, 4347 (1997).
  • 10. Cao X.L., J. Chromatogr., A 707, 145 (1995).
  • 11. Cao X.L. and Hewitt C.N., Passive sampling of organic vapours in air in [Saarela K., Kalliokoski P., Seppanem O., eds.] Indoor Air'93, Proc. 6th International Conference on Indoor Air Quality and Climate, Helsinki, July 4-8, vol. 2, 1993, pp. 227-232.
  • 12. Namieśnik J., Górecki T., Kozdroń-Zabiegała B. and Janicki W., Indoor Air, 2, 115 (1992).
  • 13. Kozdroń-Zabiegała B., Zygmunt B. and Namieśnik J., Chem. Anal. (Warsaw), 41, 1 (1996).
  • 14. Kozdroń-Zabiegała B., Przyjazny A. and Namieśnik J., Indoor Built Environ., 5, 212 (1996).
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BPP1-0009-0099
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.