In this paper experimental results of investigation of NOx removal from humid N2:02(5%):C02(15%):NO(400 ppm) mixture subjected to a positive pulsed corona discharge in a wire-to-cylinder reactor are presented. The experimental results show that NOx removal in the dry operating gas is less effective than when it is humid. The NOx removal was about 50% in the optimal conditions (9.5% of water vapour).