PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

The determination of contamination of the human body with corrosion products of metallic and silicone surgical implants

Wybrane pełne teksty z tego czasopisma
Identyfikatory
Warianty tytułu
PL
Oznaczanie kontaminacji organizmu ludzkiego produktami korozji metalicznych i silikonowych implantów chirurgicznych
Języki publikacji
EN
Abstrakty
EN
An aging population and recent developments in materials science are responsible for the increasing use of surgical implants for medical, dental and cosmetic applications. Their use, however, is not free from potential health hazards. In this paper the expedience of trace and ultra-trace concentrations of aluminum, titanium, vanadium, chromium, cobalt, molybdenum, nickel and silicon in body fluids and tissues in connection with implants-related studies are be presented. The connective tissue samples were achieved by cryogenic milling. Total sample preparation of human material is done in laboratory under Class 100 condition. Determination of metals and silicon was conducted by Graphite Furnace Atomic Absorption Spectrometry.
PL
Starzenie się ludności i osiągnięcia inżynieri materiałowej spowodowały wzrost stosowania implantów w medycynie, stomatologü i w operacjach kosmetycznych. Zastosowanie nowych materiałów stanowi potencjalne zagrożenie dla zdrowia. W pracy przedstawiono oznaczanie śladowych i ultraśladowych zawartości glinu, tytanu, wanadu, chromu, kabaltu, molibdenu, niklu i krzemu uwolnionych z implantów do płynów ustrojowych i tkanek. Próbki tkanki łącznej mielono w młynie kriogenicznym. Wszystkie próbki były badane w laboratorium klasy 100. Metale i krzem oznaczono metodą absorpcyjnej spektrometrü atomowej z zastosowaniem kuwety grafitowej.
Słowa kluczowe
PL
Czasopismo
Rocznik
Strony
1011--1019
Opis fizyczny
Bibliogr. 30 poz.
Twórcy
autor
  • Centre for Biomaterials, University of Toronto, 170 College St., Toronto, On., M5S 3E3, Canada
autor
  • Centre for Biomaterials, University of Toronto, 170 College St., Toronto, On., M5S 3E3, Canada
autor
  • Military Institute of Hygiene and Epidemiology, ul. Kozielska 4, 01-163, Warsaw, Poland
Bibliografia
  • 1. Sunderman F.W.J., Hopfer S.M., Swift T., Rezuke W.N., Ziebka L., Highman P., Edwards B., Folick M. and Gossling H.R., J. Orthop. Res., 7, 307 (1989).
  • 2. Black J., Skipor A., Jakobs J., Urban R.M. and Galante J.O., Release of metal ions from titanium-base alloy total hip replacement prostheses, Proceedings of 35th Annual Meeting of Orthopaedic Research Society, 1989.
  • 3. Stulberg B.N., Bauer T.W., Merrit K.M., Stulberg S.D. and Shull S., Characteristics of wear debris in metal backed patellar failure, Proceedings of 15th. Annual Meeting of Society for Biomaterials, 1989.
  • 4. Black J., Sherk H., Bonini J., Rostoker W.R., Schajowicz J.O. and Galante J.O., J. Bone and Joint Surg., 72-A, 126 (1990).
  • 5. Smith D.C., Lugowski S., McHugh A., Deporter D., Watson P.A. and Chipman M., Int. J. Oral Maxillofac. Implants, 12,93 (1997).
  • 6. von Schroeder H.P., Smith D.C., Gross A.E., Pilliar R.M., Kandel R.A., Chernecky R. and Lugowski S.J., J. Arthrop., 11, 620 (1996).
  • 7. Lugowski S., Smith D.C., McHugh A. and VanLoon J.C., J. Trac. Elem. Elect. H. Diseas., 5, 23 (1991).
  • 8. Michel R., Crit. Revue of Biocom., 3, 235 (1987).
  • 9. Ferguson A.B.J., Akohoshi Y., Laing P.G. and Hodge E.S., J. Bone Joint Surg., 44A, 317 (1962).
  • 10. Ferguson A.B., Akahoshi Y., Laing P.G. and Hodge E.S., J. Bone Joint Surg., 44A, 323 (1962).
  • 11. Peters W., Annal. Plast. Surg., 34, 103 (1995).
  • 12. Le Vier R.R., Harrison M.C., Cook R.R. and Lane T.H., Plast. Recon. Surg., 92, 163 (1993).
  • 13. Lugowski S., Smith D.C. and VanLoon J.C., J. Biom. Mat. Res., 21, 657 (1987).
  • 14. Lugowski S., Smith D.C. and VanLoon J.C., Trac. Elem. Med., 4, 28 (1987).
  • 15. Lugowski S., Smith D.C., McHugh A. and VanLoon J.C., J. Biom. Mat. Res., 25, 1443 (1991).
  • 16. Lugowski S., Smith D.C., McHugh A. and Lugowski J., (in prep.).
  • 17. Lugowski S., Smith D.C. and VanLoon J.C., Clin. Mat., 6, 91 (1990).
  • 18. Deporter D.A., Watson P.A., Piliar R.M., Chipman M.L. and Valiquette N., J. Dent. Res., 69, 1138 (1990).
  • 19. Deporter D.A., Watson P.A., Pilliar R.M., Chipman M. and Smith D.C., A clinical trial of a partially porous-coated endosseous dental implant in humans: Protocol and 6-month results, [W. Laney, D.E. Tolman, Eds.], Second International Congress on Tissue Integration in Oral, Orthopedic and Maxillofacial Reconstruction, Rochester, Minnesota Quintessence Books, 1990.
  • 20. Lugowski S., Ph.D. thesis, Military Institute of Hygiene and Epidemiology, Warsaw 1997 (in Polish).
  • 21. Peters W., Smith D., Lugowski S., McHugh A., Keresteci A. and Baines C., Ann. Plast. Surg., 34, 578 (1995).
  • 22. Lugowski S., Smith D., Peters W., Semple J. and McHugh A., Comparison of blood and breast milk silicon of patients with silicone breast implants and controls, Fourth International Congress of the International Society for Trace Elements Research in Humans, Taormina, Italy 1995.
  • 23. Semple J., Lugowski S., Baines C., Smith D.C. and McHugh A., (in press).
  • 24. Thiers R.E., in Methods of Biochemical Analysis [D. Glick, Ed.] Interscience, New York 1957, vol. 5, p. 274.
  • 25. Cheng C.L. and Gross A.E., J. Bone Joint Surg., 70-B, 377 (1988).
  • 26. Lugowski S., Smith D., Peters W. and McHugh A., Comparison of blood silicon of patients with silicone breast implants and controls, 16th Annual Conference of Canadian Biomaterials Society, Ottawa, Ont. 1995.
  • 27. Peters W., Smith D.C., Lugowski S., McHugh A. and Baines C., Ann. Plas. Surg., 34, 343 (1995).
  • 28. Roberts N.B. and Williams P., Clini. Chem., 36, 1460 (1990).
  • 29. Bellia J.P., Birchall J.D. and Roberts N.B., The Lancet, 343, 235 (1994).
  • 30. Lugowski S., Smith D., Semple J., Peters W. and McHugh A., Silicon levels in blood, breast milk and breast capsules of patients with silicone breast implants and controls, Fifth World Biomaterials Congress, Toronto, Ont. 1996.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BPP1-0002-0051
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.