PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

Contribution to the analytical chemistry of thiamine I. Thiamine-selective liquid membrane electrode

Autorzy
Wybrane pełne teksty z tego czasopisma
Identyfikatory
Warianty tytułu
PL
Przyczynek do chemii analitycznej tiaminy I. Tiamina jako ciekła membrana elektrody jonoselektywnej
Języki publikacji
EN
Abstrakty
EN
A nitrobenzene solution of thiamine metatungstate was used as a liquid membrane to prepare a thiamine-selective electrode. The electrode, constructed in a usual manner, without internal solution, gave improved working characteristics in terms of linear range, sensitivity, reproducibility and lifetime. Its potentiometric response was linear in the range from 3.8x10(-5) to l.0x10(-1 mol 1(-1) thiamine, with a slope of 52 mV/decade and a detection limit of 1.7x10(-5) mol 1(-1). The electrode preserves the response characteristics over a period longer than three months. The ability to discriminate between ions often accompanying the thiamine in pharmaceuticals is, from the analytical point of view, the major advantage of the electrode.
PL
Roztwór metawolframianu tiaminy w nitrobenzenie został zastosowany jako ciekła membrana, elektrody selektywnej względem tiaminy. Elektroda, skonstruowana bez roztworu wewnętrznego, charakteryzuje się korzystnymi parametrami: zakresem liniowym, czułością, odtwarzalnością i czasem życia. Elektroda wykazuje prostoliniową charakterystykę w zakresie 3,8x1(-5)-l,0x10(-1) mol 1(-1) tiaminy, z nachyleniem 52 mV/dekadę i granicą wykrywalności 1,7x105 mol l(-l) tiaminy. Elektroda zachowuje swoje parametry analityczne w okresie dłuższym niż 3 miesiące. Wysoka selektywność w stosunku do jonów które zazwyczaj towarzyszą tiaminie w preparatach farmaceutycznych jest, z analitycznego punktu widzenia, podstawową zaletą ektrody.
Czasopismo
Rocznik
Strony
437--443
Opis fizyczny
Bibliogr. 19 poz.
Twórcy
autor
  • Department of Analytical Chemistry, "Gh. Asachi" University, 71 D. Mangeron Bd. 6600 - Iassy, Romania
Bibliografia
  • 1. The United State Pharmacopoeia 1990, The United States Pharmacopoeial Convention, Rockville, MD.
  • 2. Coşofreţ V.V., Analytical Control of Drug-Type Substances with Membrane Electrodes in Ion-Selective Electrode Rev., Pergamon Press Ltd., England, 1981.
  • 3. Dessanky M. and Pungor E., Analyst, 96, 442 (1971).
  • 4. Christova R., Ivanova M. and Novkirishka M., Anal. Chim. Acta, 85, 301 (1976).
  • 5. Goldstein S. and Duca A., J. Pharm. Sci., 65, 1831 (1976).
  • 6. Suzuki S. and Karube I., Biochem. Eng., 326, 255 (1979).
  • 7. Ishibashi N., Kina K. and Maekawa M., Chem. Lett., 119 (1973).
  • 8. Kina K., Maekawa M. and Ishibashi N., Bull. Chem. Soc. Jpn., 46, 2772 (1973).
  • 9. Calu Cl., Ph. D. Thesis, Pol. Inst. Iassy, 1971.
  • 10. Nikitina E.A., Kheteropolicombinatsii (Khimia Ed.), Moscow 1962, p. 393.
  • 11. Calu Cl. and Calu N., Bull. Inst. Pol. Iassy, Tom XXVII, fasc. 3-4, 9 (1981).
  • 12. Calu Cl. and Doniga E., Rev. Roum. Chim., 27, 5, 667 (1982).
  • 13. Covington A.K. and Davison P., in Ion-Selective Electrode Methodology, (Covington A.K., Ed.) CRC, Boca Raton 1980, p. 85.
  • 14. Rǎileanu M., Medium Influence on Chemical Reactivity, (Scrisul Românesc Ed.), Craiova (România) 1981, p. 157.
  • 15. Dimroth K. and Reichardt C., Z. Analyt. Chem., 215, 344 (1966).
  • 16. Cammann K., Working with Ion-Selective Electrodes, Springer, Berlin 1979.
  • 17. Doniga E., Ph. D. Thesis, Polytechnic Institute of Iassy, Romania 1986.
  • 18. Bailey P.L., Analysis with Ion-Selective Electrodes, Heyden, London, 1980.
  • 19. Srinivasan K. and Rechnitz G.A., Anal. Chem., 41, 1203 (1969).
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BPP1-0001-0134
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.