PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

Finite Difference Time Domain Method for high resolution modeling of low frequency electric induction in humans

Wybrane pełne teksty z tego czasopisma
Identyfikatory
Warianty tytułu
PL
Metoda FDTD w modelowaniu z wysoką rozdzielczością indukowanego pola elektrycznego niskiej częstotliwości w człowieku
Języki publikacji
EN
Abstrakty
EN
The paper deals with the implementation of low frequency finite difference time domain method (FDTD) algorithm in the investigation of induced electric field in the human body model with digitally implanted cardiac pacemaker. In order to investigate if the basic restrictions could be exceeded according to international standards, the induced electric fields at both the input port of cardiac pacemaker and at the tip of electrode were calculated.
PL
W artykule rozpatrzono implementację algorytmu FDTD dla niskich częstotliwości do analizy pola elektrycznego indukowanego w ciele człowieka z wszczepionym stymulatorem serca. W celu sprawdzenia czy nie przekroczono standardów bezpieczeństwa, wyznaczono wartości natężenia indukowanego pola elektrycznego w obszarze stymulatora oraz w sąsiedztwie elektrody w komorze serca.
Rocznik
Strony
225--227
Opis fizyczny
Bibliogr. 13 poz., rys., tab.
Twórcy
autor
  • Agricultural University in Lublin
Bibliografia
  • [1] Taflove A., Computational Electrodynamisc, Finite Fifference Time Domain Method, 3rd Edition, Artech House, Boston 2005
  • [2] Moerloose J., Dawson T.W., Stuchly M., Application of finite difference time domain algorithm to quasi-static field analysis, Radio Sci. 1997, 32(2), pp. 329
  • [4] Furse CM, Gandhi O.P, Calculation of electric fields and currents induced in a millimeter-resolution human model at 60 Hz using the FDTD method, Journal of Bioelectromagnetics 1998, 19:293-299.
  • [5] Gandhi O.P, Chen J.Y, Numerical dosimetry at power-line frequencies using anatomically based models, Bioelectromagnetics 1992, (Suppl 1): 43-60
  • [6] Gandhi O.P, Kang G, Wu D., Lazzi G., Currents Inducedin Anatomic Models of the Human for Uniformand Nonuniform Power Frequency Magnetic Fields, Bioelectromagnetics 2001, 22:112-121
  • [7] IEC, Medical Electrical Equipment, Part 1: General Requirements for Safety, IEC Standard 601-1-2, 2001
  • [8] ICNIRP, Guidelines for limiting exposure to time-varying electric, magnetic, and electromagnetic fields (up to 300 GHz), Health Phys., vol. 41, no. 4, pp. 449-522, 1998
  • [9] Farjadpour A., Roundy D., Rodriguez A., Ibanescu M., Bermel P., Joannopoulos J. D.,. Johnson S.G, and Geoffrey Burr, Improving accuracy by subpixel smoothing in FDTD, Optics Letters, 2006
  • [10] www.cst.com
  • [11] http://www.nlm. nih.gov/research/visible/visible_human. html
  • [12] Gabriel S., The dielectric properties of biological tissue: Part III - Parametric model for dielectric spectrum of tissues, Phys. Med. Biol., vol. 41, pp. 2271-2293, 2001
  • [13] Gustrau F., Bahr A., Rittwerger M., Goltz S., Eggert S., Simulation of Induce Currant Densities in the Human Body at Industrial Induction Heating Frequencies, IEEE Tran. on Elect. Compatibility, vol. 41, no. 4, pp. 480-486, 1999
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BPOZ-0006-0020
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.