The Application of Partial Discharge Detection for the condition assessment of XLPE Power Cables

Autorzy
Wybrane pełne teksty z tego czasopisma
Identyfikatory
Warianty tytułu
PL
Metody wykorzystania wyładowania niezupełnego do testowania stanu kabli typu XLPE
Języki publikacji
EN
Abstrakty
EN
Partial discharge (PD) detection is an important means in the condition-based maintenance of high voltage apparatus including crosslinked polyethylene (XLPE) power cables. In this contribution, we introduce the recent work in Shanghai municipal electric power company on the condition-based maintenance of XLPE power cables. As to how to carry out the PD detection in different circumstances, three schemes are laid out in brief. Particularly, a novel idea of partial discharge joint detection method, which is based on multiple sensors, or the high frequency current transformer (HFCT) coupling technique, ultra high frequency (UHF) and acoustics emission (AE) partial discharge detection technique, is proposed. Use more than one kind of coupling techniques, the reliability of onsite PD detection and diagnosis can be improved significantly.
PL
Przedstawiono metody wykorzystania wyładowania niezupełnego do testowania stanu kabli typu XLPE. Wykorzystano różne czujniki, jak np. wysokoczęstotliwościowy transformatorowy czujnik prądu czy czujniki emisji akustycznej.
Słowa kluczowe
Rocznik
Strony
313--316
Opis fizyczny
Bibliogr. 13 poz., rys.
Twórcy
autor
autor
autor
Bibliografia
  • [1] J.E. McBride, V.S. Harper, L.T. Coffeen, F.T. Stanley, H.W. Ng, Examination and location of partial discharge sites in severely aged underground distribution cables, IEEE Transactions on Power Delivery, 9(1994) No. 2, 629 – 638
  • [2] Guo Canxin, Huang Chengjun, Qian Yong, Liu Junhua and Jiang Xiuchen, The Electroquasistatic Field Simulation and Analysis for the Insulation Defects in XLPE Power Cables, International Review of Electrical Engineering, 4(2009),No. 6, 1413 – 1417
  • [3] Y. Tian, P.L. Lewin, A.E. Davies, Comparison of on-line partial discharge detection methods for HV cable joints, IEEE Transactions on Dielectrics and Electrical Insulation, 9(2002),No.4, 604 – 615
  • [4] Liu Junhua, Huang Chengjun, Qian Yong and Jiang Xiuchen, Analysis on Partial Discharge Localization Using UHF Combined with Acoustic Method in GIS, International Review of Electrical Engineering, 5(2010),No.3, 1040 – 1044
  • [5] Guo Canxin, Zhang Lianhong, Yao Linpeng, Qian Yong, Huang Chengjun and Jiang Xiuchen, Application of HF/UHF Joint Partial Discharge Analysis to On-site Power Cable Terminal Detection, Electrical Power Automation Equipment, 30(2010), No.5, 92 - 95
  • [6] J.Moshtagh, P. Jalili, High Impedance Fault Location for Aged Power Distribution Cables Using Combined Neural Networks & Wavelet Analysis, International Review of Electrical Engineering, 4(2009), No.5, 967 – 975
  • [7] H. Vahedi, M. Yazdani-Asrami, A New Diagnostic Test for Power Cables Based on Frequency Analysis, International Review of Electrical Engineering, 5 (2010),1784 – 1788
  • [8] Guo Canxin, Zhang Li, Qian Yong, Huang Chengjun, Yao Linpeng and Jiang Xiuchen, Current Status of Partial Discharge Detection and Location Techniques in XLPE Power Cable, High Voltage Apparatus, 45(2009), No.3, 56 - 60
  • [9] Luo Junhua, Feng Jiang, Yuan Jian, Ma Cuijiao and Qiu Yuchang, Study on Detection of Partial Discharge in XLPE Cable at Higher Frequency, Power System Technology, 25(2001), No.12, 42 - 45.
  • [10] Luo Junhua, Ma Cuijiao and Qiu Yuchang, On-line Partial Discharge Detection in XLPE Cables, High Voltage Engineering, 25(1999), No.4, 32 - 34
  • [11] Qian Yong, Huang Chengjun, Jiang Xiuchen and Xiao Yan, Present Situation and Prospect of Ultrahigh Frequency Method Based Research of On-line Monitoring of Partial Discharge in Gas Insulated Switchgear, Power System Technology, 29(2005), No.1, 40 - 43
  • [12] Guo Canxin, Zhang Lianhong, Yao Linpeng, Qian Yong, Huang Chengjun and Jiang Xiuchen, Application of HF/UHF Joint Partial Discharge Analysis to On-site Power Cable Terminal Detection, Electrical Power Automation Equipment, 30(2010), No.5, 92 - 95
  • [13] Geng Xuxu, Zhang Li, Guo Canxin, Qian Yong, Huang Chengjun and Jiang Xiuchen, Portable XLPE Cable Insulation Detection Device, Electric Engineering, 11(2009), No.1, 27 - 29
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BPOK-0039-0071
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.