PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

Control of Voltage Source Inverter with an LCL Filter without Voltage Sensors

Autorzy
Wybrane pełne teksty z tego czasopisma
Identyfikatory
Warianty tytułu
PL
Sterowanie przekształtnikiem napięciowym z filtrem LCL bez konieczności używania czujników napięcia
Języki publikacji
EN
Abstrakty
EN
The voltage source inverter with LCL filter has to adopt damping method to suppress the resonance of LCL filter, which increases of losses and sensors. With virtual flux estimation idea, grid voltage-sensor-less technology is applied to design observers for the grid voltage, capacitor voltage and current. The observed grid voltage and capacitor voltage is used to realize voltage orientation control and grid current compensation for unit power factor. The observed capacitor current was fed forward to restrain LCL response and keep the control stable. The simulation results verify the correctness of observes design and the control method.
PL
W artykule analizuje się przekształtnik o źródle napięciowym VSI z filtrem LCL w zastosowaniu do sieci elektrowni wiatrowych. Analizę przeprowadza się na podstawie monitorowania napięcia sieci, prądu sieci i napięcia na kondensatorze.
Rocznik
Strony
119--122
Opis fizyczny
Bibliogr. 11 poz., schem.
Twórcy
autor
autor
autor
autor
  • Wind Power Research Center & State Key Laboratory of Ocean Engineering, Shanghai Jiao Tong University
Bibliografia
  • [1] F. Blaabjerg, R. Teodorescu, M. Liserre, A. V. Timbus, Overview of control and grid synchronization for distributed power generation systems, IEEE Transactions on Industry Applications, 53(2006), No.5,1398- 1409
  • [2] B. Singh, B.N. Singh, A. Chandra, et al., A review of threephase improved power quality AC-DC converters, IEEE Trans. On Industrial Electronics, 51(2004), No.3, 641- 660
  • [3] Dannehl J., Wessels C., Wilhelm F.F., Limitations of Voltage-Oriented PI Current Control of Grid-Connected PWM Rectifiers With LCL Filters, IEEE Trans. On Industrial Electronics, 56(2009), No.2, 380- 388
  • [4] M. Liserre, F. Blaabjerg, S. Hansen, Design and control of an LCL-filter-based three-phase active rectifier, IEEE Trans. On Industry Applications, 41(2005), No.5, 1281-1291
  • [5] M. Prodanovic and T.C. Green, Control and filter design of three-phase inverters for high power quality grid connection, IEEE Trans. On Power Electronics, 18(2003), No.1, 373-380
  • [6] Twining E.,Donald G.H.,Grid current regulation of a threephase voltage source inverter with an LCL input filter, IEEE Trans. on Industry Applications, 18(2003), No.3 , 888-895
  • [7] Malinowski M., Kamierkowski M., Hansen S. Blaabjerg F. et al., Virtual-Flux-Based Direct Power Control of Three-Phase PWM Rectifiers, IEEE Trans. On Industry Applications, 37(2001), No.4, 1019-1027
  • [8] Malinowski M. and Bernet S., A Simple Voltage Sensorless Active Damping Scheme for Three-Phase PWM Converters With an LCL Filter, IEEE Trans. On Industrial Electronics, 55(2008), No.4, 1876-1880
  • [9] Agriman I., Blasko V., A Novel Control Method of a VSC Without AC Line Voltage Sensors, IEEE Trans. Industry Applications, 39(2003), No.2, 519- 524
  • [10] Ohnuki T, Miyashita O, Lataire Ph., Control of a Three-Phase PWM Rectifier Using Estimated AC-Side and DC-Side Voltages, IEEE Trans. On Power Electronics, 14(1999), No.2, 222- 226
  • [11] Suul J.A., Luna A., Rodriguez P., et al., Voltage-Sensor-Less Synchronization to Unbalanced Grids by Frequency-Adaptive Virtual Flux Estimation, IEEE Trans. On Industrial Electronics, 59(2011), No.7, 2910- 2923