PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

Analysis of Excitation Current in DC-Biased Transformer by Wavelet Transform

Autorzy
Wybrane pełne teksty z tego czasopisma
Identyfikatory
Warianty tytułu
PL
Wykorzystanie transformaty falkowej do analizy prądu magnesującego transformatora podmagnesowanego składową DC
Języki publikacji
EN
Abstrakty
EN
To analyze the excitation current in DC-Biased Transformer in depth, the thesis deduces the mathematical expression of distortion excitation current, and put forwards the analysis method with wavelet transform principle, which directs at analyzing the boundedness of distortion excitation current using the Fourier Transform. Through sampling the distortion excitation current signal, we resolve its wavelet LF approximation signal and HF detail signal, conclude DC component size of the distortion excitation current, confirm the moment of excitation current waveform distorting, comparatively analyze the results after Fourier Transform, and make clear that the principle is feasibility and superiority. Through analyzing the energy spectrogram in the signal high-frequency band of distortion excitation current and short circuit current are determined. Simulation results show that energy changes in the high frequency band among the different scale. In practice, DC bias can lead to the action of relay protection device, which does harm to the system potentially.
PL
Przedstawiono metodę analizy składowej stałej podmagnesowującej w prądzie magnesującym transformatora. Do analizy wykorzystuje się transformatę falkową I transformatę Fouriera prądu magnesującego.
Rocznik
Strony
108--112
Opis fizyczny
Bibliogr. 18 poz., schem.
Twórcy
autor
autor
autor
autor
  • Tianjin Key Laboratory for Control Theory & Applications in Complicated Systems
Bibliografia
  • [1] Lahtinen M, Elovaara J. GIC occurrences and GIC test for 400 kV system transformer[J]. IEEE Transactions on Power Delivery, 2002, 17(2): 555-561.
  • [2] Xuesong Zhou, Zhihao Zhou, Youjie Ma. Research on Effects of Geomagnetic Induced Currents to Power Systems[C], Advanced Materials Research, 2011, 317-319, 2037.
  • [3] Luo Jianwu, Luo Wenjie. The cause and eliminating method of magnetic-shift[J]. Transactions of China Electrotechnical Society, 1999, 14(6): 73-77(in Chinese).
  • [4] He Junjia, Ye Huisheng, Lin Fuchang, et al. Influence of soil structure on direct current flowing into neutral point of power transformer[J]. Proceedings of the CSEE, 2007, 27(36): 14- 18(in Chinese).
  • [5] Miyagi D, Yoshida T, Nakano M, et a. Development of measuring equipment of DC-biased magnetic properties using open-type single-sheet tester[J]. IEEE Trans. on Magnetics, 2006, 42(10): 2846-2848.
  • [6] Picher P, Bolduc L, Dutil A, et al. Study of the acceptable DC current limit in core-form power transformers[J]. IEEE Trans. on Power Delivery, 1997, 12(1): 257-265.
  • [7] Li Xiaoping, Wen Xishan, Lan Lei, et al. Test and simulation for single-phase transformer under DC bias[J].Proceedings of the CSEE, 2007 , 27(9): 34-40(in Chinese).
  • [8] Zhao Xiaojun, LI Lin, Cheng Zhiguang, et al. Analysis of the DC Bias Phenomenon in Transformers Based on Harmonicbalanced Finite Element Method[J]. Proceedings of the CSEE, 2010,30(21):103-10(in Chinese).
  • [9] Li Xiaoping, Wen Xishan, Fan Yadong, et al. Computation of exciting current and harmonic for three-phase and three limbs transformer under DC inrushing[J]. High Voltage Engineering, 2006, 32(5):69-72(in Chinese).
  • [10] Simulation of transformer DC magnetic biasing[J]. Guangdong Electric Power, 2004, 17(2): 5-9(in Chinese).
  • [11] Sun Yunlian; Luo Weihua; Li Hong. Extract Signals of Power Line Communication by a Novel Method Based on EMD and ICA [J]. Proceedings of the CSEE, 2007, 27(16): 109-113(in Chinese).
  • [12] Li Hongzhi,Cui Xiang, Liu Dongsheng, et al .Influence on Three-Phase Power Transformer by DC Bias Excitation [J]. Transactions of China Electrotechnical Society, 2010,25(5):88-96.
  • [13] L.Boldue, A.Gaudreau and A.Dutil.Suration time of transfonmers under dc excitation [J] Electric power Systems Research, 2000, 56(l):95 一102.
  • [14] L.Bolduc, A.Gaudreau, A.Dutil. Saturation time of transformers under dc excitation. Electric Power Systems Research, 2000:95-102.
  • [15] Time-varying harmonic detection Based on wavelet transform [J].Automation of Electric Power Systems,1998, 22 (8) : 52- 54
  • [16] An yuan, Liu jiajun. Transformer inrush identification method Based on wavelet theory and multiresolution analysis[J].Power System Technology, 2007 (17) :21-25
  • [17] Yang Fusheng. Wavelet Transform for Project Analysis and Application [M]. Beijing: SciencePress 2000.
  • [18] Hu changhua, Li guohua, Liu Tao. System analysis and design based MATLAB6.X - Wavelet Analysis [M] Xi'an University of Electronic Science and Technology Press, 2004,1.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BPOK-0037-0026
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.