Distribution transformers protection against High Frequency Switching Transients

Wybrane pełne teksty z tego czasopisma
Identyfikatory
Warianty tytułu
PL
Ochrona transformatorów dystrybucyjnych przed wysokoczęstotliwościowymi przepięciami łączeniowymi
Języki publikacji
EN
Abstrakty
EN
Distribution transformers protection method against high frequency transients generated during Vacuum Circuit Breaker (VCB) operations is presented in this paper. ATP/EMTP simulations of transients generated during the VCB operation and protection method effectiveness is described. In addition prototype windmill installation is presented. For simulations realistic VCB model was used enabling one to study both prestrikes, generated during the contact making process as well as re-ignitions generated during the contact breaking.
PL
W artykule przedstawiono metodę ochrony transformatorów dystrybucyjnych przed wysokoczęstotliwościowymi przepięciami generowanymi podczas operacji łączeniowych z użyciem wyłączników próżniowych. W artykule przedstawiono symulacje komputerowe przepięć generowanych zarówno podczas załączania jak i wyłączania transformatorów. Symulacji dokonano przy użyciu pakietu ATP/EMTP. Zaprezentowano również przykładową istniejącą instalację opisanych w artykule urządzeń.
Rocznik
Strony
296--300
Opis fizyczny
Bibliogr. 8 poz., rys.
Twórcy
autor
autor
autor
autor
Bibliografia
  • [1] CIGRE working group A2-A3-B3.21, Electrical Environment of Transformers; Impact of fast transients”, ELECTRA 208, (2005)
  • [2] Lopez–Roldan J., De Herdt H., Min J., Van Velthove R., Decklerq J., Sels T., Karas J., Van Dommelen D., Popow P., Van der Sluis L., Aquado M., Study of interaction between distribution transformer and vacuum circuit breaker, Proceedings of 13th ISH (2003), pp. 62÷64
  • [3] Morched A.S., Marti L., Brierly R.H., Lackey J.G., Analysis of Internal Winding Stresses in EHV Generator Set-Up Transformer Failures, IEEE Trans. on Power Delivery, Vol. 11, No. 2, (1996), pp. 888÷894
  • [4] Popov M., Acha E., Overvoltages due to switching off an unloaded transformer with a vacuum circuit breaker, IEEE Trans. on Power Delivery, Vol. 14, No. 4, (1999), pp. 1317÷1322
  • [5] Burrage L.M., Shaw J.H., McConnell B. W., Distribution transformer performance when subjected to steep front impulses, IEEE Trans. on Power Delivery, Vol. 5, No. 2, (1990)
  • [6] Piasecki W., Bywalec G., Florkowski M., Fulczyk M., Furgal J., New approach towards Very Fast Transients suppression, Proceedings of IPST’2007
  • [7] Paul D., Failure Analysis of Dry-Type Power Transformer, IEEE Transaction on Industry Applications, Vol. 37, No. 3, (2001)
  • [8] Wong S.M., Snider L.A., Lo E.W.C., Overvoltages and reignition behavior of vacuum circuit breaker, Proceedings of IPST’2003
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BPOK-0036-0071
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.