Mixed Commutation Techniques and their Influence on Loss in the Three-Phase Voltage-Feed Zero Current Switching Inverter

Autorzy
Wybrane pełne teksty z tego czasopisma
Identyfikatory
Warianty tytułu
PL
Mieszane metody komutacji i ich wpływ na straty w trójfazowym falowniku napięcia przełączanym w warunkach zerowego prądu
Języki publikacji
EN
Abstrakty
EN
The paper presents the hard and soft commutation influence on loss in the three-phase ZCS inverter which can be implemented in the electric cars drive systems. A very low switching loss level, for nominal load current conditions is typical for this kind of inverter. In the range where load current has small value, loss reduction obtained thanks to soft-switching does not to compensate additional conduction loss in the auxiliary switches. Therefore in this load current range, the hard-switching warrants lower total loss level. The experimental research of the 3 kW three-phase ZCS inverter has been done. The merits and disadvantages of implemented control method were shown.
PL
Niniejszy artykuł przedstawia wpływ zastosowania komutacji: twardej i miękkiej na straty w trójfazowym falownika typu ZCS, który może być zastosowany w układach napędowych pojazdów elektrycznych. Falownik tego rodzaju charakteryzuje się bardzo niskim poziomem strat przełączania dla prądów znamionowych. W zakresie prądów obciążenia o niewielkiej wartości, ograniczenie strat przełączania przez komutację miękką nie rekompensuje dodatkowych strat przewodzenia w łącznikach pomocniczych. Zatem w tym zakresie prądów obciążenia komutacja twarda zapewnia niższy poziom strat całkowitych. Przeprowadzono badania eksperymentalne trójfazowego falownika typu ZCS o mocy około 1,5kW. Przedstawiono zalety i wady zastosowanej metody sterowania.
Słowa kluczowe
Rocznik
Strony
244--246
Opis fizyczny
Bibliogr. 9 poz., rys.
Twórcy
autor
Bibliografia
  • [1] McMurray W.: SRC Inverter Commutated by Auxiliary Impulse. IEEE Transactions on Communications and Electronics, Vol. 8-75 Nov/Dec., 1964, pp. 824-829.
  • [2] Hua G., Yang E., Jiang Y., Lee F. C.: Novel Zero-Current-Transition PWM Converters for High Power Applications. In Proceedings of IEEE-PESC, 1993, pp. 538-544.
  • [3] Mao H., Lee F. C., Zhou X., Boroyevich D.: Improved Zero-Current –Transition Converters for High Power Applications. In Proceedings of IEEE-IAS, 1996, pp. 1145-1152.
  • [4] Li Y., Lee F. C.: Design Considerations for a 50-kW Soft-Transition Inverter with Zero-Current and Near-Zero-Voltage Switching. In Proceedings of IEEE-APEC, 2001, pp. 931-937.
  • [5] Li Y., Lee F. C., Lai J., Boroyevich D.: A Low-Cost Three-phase Zero-Current-Transition Inverter with Three Auxiliary Switches. In Proceedings of IEEE-PESC , Vol 1, 2000, pp. 527-532.
  • [6] Li Y., Lee F. C., Katsis D., Mao Y.: Design of 50-kW Three- Phase Zero-Current-Transition Inverter with Three Auxiliary Switches for Electric Propulsion Drives. In Proceedings of IEEE-PESC 2001, pp. 311-318.
  • [7] Li Y., Lee F. C.: Design Methodologies for High-Power Three- Phase Zero-Current-Transition Inverters. In Proceedings of IEEE-PESC 2001, pp. 1217-1223.
  • [8] Li Y.P., Lee F.C, Boroyevich D.: A simplified three-phase zerocurrent-transition inverter with three auxiliary switches, In Proceedings of IEEE Transaction Power Electronics, vol. 18, no. 3, may 2003, pp. 803-813.
  • [9] Karyś S.: Analiza strat trójfazowego falownika o komutacji miękkiej ZCS sterowanego metodą PWM, Elektronika, konstrukcje, technologie zastosowania, Warszawa 2009, nr 9, pp. 152-156.