PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

CPC-based comparison of compensation goals in systems with nonsinusoidal voltages and currents

Wybrane pełne teksty z tego czasopisma
Identyfikatory
Warianty tytułu
PL
parte na teorii Składowych Fizycznych Prądu (CPC) porównanie celów kompensacji w systemach z niesinusoidalnymi przebiegami prądu i napięcia
Języki publikacji
EN
Abstrakty
EN
There is some level of confusion upon goals of compensation in systems with nonsinusoidal voltages and currents (NV&C), especially considering that compensation with switched compensators is a recursive process. This recursive nature of compensation is often ignored in discussions on compensation. This paper presents results of studies on recursive compensation with a switching compen-sator, aimed at reducing the supply current to its active component, defined according to Fryze, according to CPC power Theory, and to its working component. The paper also shows that the instantaneous reactive power p-q theory-based algorithm for switching compensator control, does not provide, in the presence of the supply voltage harmonics and/or asymmetry, right control of such compensators.
PL
Cele kompensacji w obwodach z niesinusoidalnymi przebiegami prądu i napięcia nie są jednoznacznie zdefinowane i są ciągle przedmiotem dyskusji, szczególnie, że kompensacja jest procesem iteracyjnym. Ten iteracyjny charakter kompensacji jest często w dyskusjach nad kompensacją pomijany. Artykuł przedstawia wyniki badań nad iteracyjnym procesem kopensacji, którego celem jest minimalizacja prądu zasilania do prądu czynnego w sensie Fryzego i w sense Teorii CPC, a także wtedy, gdy tym celem kompensacji jest redukcja prądu zasilania do prądu roboczego. Artykuł pokazuje, że teoria chwilowej mocy biernej, p-q, w warunkach zasilania odbiornika napięciem odkształconym lub asymetrycznym, nie tworzy poprawnych podstaw dla generowania sygnałów sterujących kompensatora.
Rocznik
Strony
22--29
Opis fizyczny
Bibliogr. 10 poz., rys.
Twórcy
autor
autor
  • Department of Electrical and Computer Engineering, Louisianan State University, Baton Rouge, USA, lsczar@cox.net
Bibliografia
  • [1] Akagi H., Kanazawa Y., Nabae A., (1984) Instantaneous reactive power compensators comprising switching devices without energy storage components, IEEE Trans. IA, IA-20, No. 3, 625-630.
  • [2] Akagi H., Nabae A., (1993) The p-q theory in three-phase systems under non-sinusoidal conditions, Europ. Trans. on Electr. Power, ETEP, Vol. 3, No. 1, 27-31.
  • [3] Montano J.-C, Salmeron P., (1999) Identification of instantaneous current components in three-phase systems, IEE Proc. Science, Measur. and Technology, Vol. 146, No. 5, 227-233.
  • [4] Czarnecki L.S., (2004) On some misinterpretations of the Instantaneous Reactive Power p-q Theory, IEEE Trans. on Power Electronics, 19 No.3, 828-836.
  • [5] Willems J.L., (2008) Critical comparison of variuos decomposition and compensation schames in power systems, Przegląd Elektrotechniczny, (Electrical Review), R84, No. 11, 316-321.
  • [6] Watanabe E. H., Akagi H., and Aredes M., (2008): Instantaneous p-q Power Theory for compensating nonsinusoidal systems, Przegląd Elektrotechniczny, R84, No. 6, pp. 28-37.
  • [7] Czarnecki L.S., (2008) Currents’ Physical Components (CPC) concept: a fundamental for power theory, Przeglad Elektrotechniczny (Electrical Review), R84, No. 6, pp.28-37.
  • [8] Czarnecki L.S., Pearce S. E., (2009) Compensation objectives and CPC–based generation of reference signals for shunt switching compensator control, IET Power Electronics, Vol. 2, No. 1, 33-41.
  • [9] Czarnecki L.S., (2009) Effect of supply voltage harmonics on IRP p-q-based switching compensator control, IEEE Trans. on Power Electronics, Vol. 24, No. 2, 483-488.
  • [10] Czarnecki L.S., (2010) Effect of supply voltage asymmetry on IRP p-q - based switching compensator control, IET Power Electronics, Vol. 3, No. 1, 11-17.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BPOK-0031-0003
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.