Detection of high frequency magnetic signature for large electrical machines: a monitoring tool

Wybrane pełne teksty z tego czasopisma
Identyfikatory
Warianty tytułu
PL
Detekcja pola magnetycznego wysokiej częstotliwości w dużych maszynach elektrycznych: narzędzie monitorowania
Języki publikacji
EN
Abstrakty
EN
The turn-to-turn insulation quality of electrical machines can be monitored using high frequency resonance detection in windings. Indeed, for standard turn insulation made of polyester-imide and polyamide-imide coating, the polymer aging causes a slight increase of the turn-to-turn capacitance therefore a slight change of several winding resonance frequencies. Such change can be detected by an appropriate monitoring system. For large machines, the interesting spectrum is in the range 10MHz -50MHz. The paper describes a method based on magnetic field measurements able to detect such resonance frequencies for large machines.
PL
Jakość izolacji wokół cewek maszyn elektrycznych może być monitorowana stosując metodę detekcji rezonansem wysokoczęstotliwościowym. Rzeczywiście, dla standardowej izolacji zwoju wykonanej z poliestroamidu i pokrytego poliamidowa powłoką, starzenie powoduje niewielki wzrost pojemności miedzyzwojowej dla różnych częstotliwości rezonansowych. Taka zmiana może być wykryta za pomocą odpowiedniego systemu monitoringu. W przypadku dużych maszyn, ciekawe spektrum występuje w zakresie 10MHz-50MHz. W artykule opisano metodę opartą na pomiarach pola magnetycznego dla dużych maszyn.
Rocznik
Strony
1--4
Opis fizyczny
Bibliogr. 11 poz., il., schem., wykr.
Twórcy
autor
autor
Bibliografia
  • [1] Dissado L.A., Fothergill J.C., “Electrical degradation and breakdown in polymers’’, IEE Materials and Devices Series 9, Ed. G.C. Stevens (Ed.) (P. Peregrinus Ltd. London, UK, June (1992)
  • [2] Stone G.C., Boulter E.A., Culbert I., Dhirani H., “Electrical Insulation for Rotating Machines”, IEEE Press Series on Power Engineering, (2004), 73 – 94
  • [3] Perisse F., Werynski P., Roger D., ”A New Method for AC Machine Turn Insulation Diagnostic Based on High Frequency Resonances’’, IEEE Trans. on Dielectrics and Insulation Systems, Vol.14 (2007), No.5, 1308-1315
  • [4] Werynski P., Roger D., Corton R., Brudny J.F., “Proposition of a New Method for In-Service Monitoring of the Aging of Stator Winding Insulation in AC Motors’’, IEEE Transactions on Energy Conversion, Vol. 21 (2006), No. 3, 673-681
  • [5] Savin S., Ait-Amar S., Roger D., Vélu G., ‘’Prospective Method for Partial Discharge Detection in Large AC Machines using Magnectic Sensors in Low Electric Field Zones’’,the Applied Computational Electromagnetics Society Journal, vol 26 (2011), N. 9, 729-736
  • [6] Agilent Accurate Impedance Measurement with Cascade Microtech Probe System, Guide, 2nd Edition, Number of publication 5950-3000
  • [7] Agilent 4294A Precision Impedance Analyzer Operation Manual Seventh Edition, Part No. 04294- 90060, February (2003)
  • [8] Romary R., Roger D., Brudny J.F., ‘’Wide frequency range analysis of the electromagnetic emissions of electrical machine for diagnosis’’,the European Physical Journal Applied Physics. 43 (2008), 165-172
  • [9] Dehmel G., Magnetic field sensors: induction coil (search coil) sensors – A comprehensive Survey, Vol 5 (NewYork: VCH), chapter 6 (1989), 205-54
  • [10] Duchesne S., Lecointe J., Périsse F., Napieralska-Juszczak E., ‘High frequency electromagnetic emissions of cylindrical laminated cores’’ Compel, vol 26 (2008), N. 4, 735-743
  • [11] Duchesne S., Napieralska-Juszczak E., Roger D., ‘Eddy current influence on electromagnetic emissions of laminatem cores, Compel, vol 26 (2007), N. 4, 986-1004