PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

Passivity-based Controller Design and Stable Control Region Analysis of the Cascaded DSTATCOM

Autorzy
Wybrane pełne teksty z tego czasopisma
Identyfikatory
Warianty tytułu
PL
Bazujący na analizie składowej biernej układ sterowania w systemie kaskadowo połączonych DSTATCOM
Języki publikacji
EN
Abstrakty
EN
This paper proposes a novel passivity-based control scheme for the cascaded H-bridge (CHB) DSTATCOM. The mathematical model of the CHB-DSTATCOM is devised by partitioning the CHB-DSTATCOM into n-block subsystems, and the control algorithm is devised using the adaptive passivity controller. The power balancing mechanism and the stable control region are analyzed using the phasorial diagram representation. The Electromagnetic Transient Program (EMTP) is used for digital simulation, and the Transient Analysis of Control System (TACS) and the MODELS language of the EMTP are utilized for control algorithm implementation. The simulation results of the CHB-DSTATCOM under abrupt dclink voltage variations are provided with comparative evaluations. The devised control scheme of the CHB-DSTATCOM is validated by the simulation and experimental results from the prototype system.
PL
W artykule zaproponowano układ sterowania kaskadowo połączonych systemów DSTATCOM biorąc pod uwagę składowa bierną mocy. Mechanizm równoważenia mocy i sterowanie stabilnością są analizowane na podstawie reprezentacji fazora.
Rocznik
Strony
140--148
Opis fizyczny
Bibliogr. 26 poz., schem., wykr.
Twórcy
autor
autor
Bibliografia
  • [1]Biricik S., Ozerdem O., Investigation of switched capacitors effect on harmonic distortion levels and performance analysis with active power filter, Przeglad Elektrot., 85(2010), n.11a, 13-17.
  • [2]Rzasa J., Simulation research of variable impedance type series compensator, Przeglad Elektrot., 85(2010), n.12, 216-223.
  • [3]Kaczmarek M., Examination and analysis of parameters describing the output signal in the system for distorted voltage generation, Przeglad Elektrot., 85(2010), n.11b, 99-102.
  • [4]Moradlou M., Karshenas H.R., Design strategy for optimum rating selection of interline DVR, IEEE Trans. on Power Deliv., 26(2011), no.1, 242-249.
  • [5] Han Y., Xu L., Yao G., Zhou L., Khan MM, Chen C., Flicker mitigation of arc furnace load using modified p-q-r method, Przeglad Elektrot., 85(2009), n.1, 225-229.
  • [6] Sergio V., Jose IL., Juan M.C., Leopoldo GF., etc., Analysis of the power balance in the cells of a multilevel cascaded Hbridge converter, IEEE Trans. Ind. Electron., 57(2010), n.7, 2287-2296.
  • [7] Han Y., Xu L., Yao G., Zhou LD., Khan MM., Chen C., A novel modulation scheme for dc-voltage balancing control of cascaded H-bridge multilevel APF, Przeglad Elektrot., 85(2009), n. 5, 81-85.
  • [8] Stala R., Pirog S., Baszynski M., Mondzik A., Penczek A., Czekonski J., Gasiorek S., Results of investigation of multicell converters with balancing circuit-Part I, IEEE Trans. Ind. Electron., 56(2009), n.7, 2610-2619.
  • [9] Han Y., Xu L., Yun WJ., Yao G., Zhou LD., Khan MM., Chen C., Power quality enhancement for automobile factory electrical distribution system-strategies and field practice, Przeglad Elektrot., 85(2009), n. 6, 159-163.
  • [10] Barrena J., Marroyo L., Vidal M., Apraiz J., Individual voltage balancing strategy for PWM cascaded H-bridge converterbased STATCOM, IEEE Trans. Ind. Electron., 55(2008), n.1, 21-29.
  • [11] Han Y., Xu L., Yao G., Zhou LD., Khan MM., Chen C., Power system harmonic estimation scheme based on Affine projection adaptive filter theory, Przeglad Elektrot., 85(2009), n. 11, 45-50.
  • [12]Milanovic J.V., Yan Z., Modelling of FACTS devices for voltage sag mitigation studies in large power systems, IEEE Trans. on Power Deliv.,25(2010), no.4, 3044-3052.
  • [13]Kinhal V.G., Agarwal P., Gupta H.O., Performance investigation of neural-network-based unified power quality conditioner, IEEE Trans. on Power Deliv., 26(2011),no.1, 431-437.
  • [14] Han Y., Xu L., Yao G., Zhou L., Khan MM, Chen C., A Robust Deadbeat Control Scheme for Active Power Filter with LCL Input Filter, Przeglad Elektrot., 86(2010), n.2, 14-19.
  • [15] Han Y., Xu L., Khan MM, Chen C., Yao G., Zhou L., Modelling and controller synthesis of a hybrid-LCL APF for power quality conditioning applications, Przeglad Elektrot., 86(2010), n.9, 326-333.
  • [16]Witek B., Selected optimization problems in electric power systems with distributed generation and FACTS elements, Przeglad Elektrot., 86(2010), n.8, 113-118.
  • [17]Han Y., Xu L., Khan MM., Chen C., Power balancing control strategies for the cascaded H-bridge multilevel DSTATCOM, Przeglad Elektrot., 87(2011), n.2, 212-219.
  • [18]Freitas W.,Morelato A.,Wilsun X.,Sato F., Impact of AC generators and DSTATCOM devices on the dynamic performance of distribution systems, IEEE Trans. on Power Deliv., 20(2005), vol.2, part 2, 1493-1501.
  • [19]Mitra P., Venayagamoorthy G. K., An adaptive control strategy for DSTATCOM applications in an electric ship power system, IEEE Trans. on Power Electron., 25(2010), no.1, 95-104.
  • [20]EI-Sharkawi MA., Dong M., Huang T., Szofran A. Andexler G., Venkata S.S., Butler N., Rodriguez A., Kerszenbaum A., Development and field testing of a 15-kV class adaptive var compensator, IEEE Trans. on Power Deliv., 10(1995), no.4, 1979-1986.
  • [21]Cheng C., Hsu Y., Damping of generator oscillations using an adaptive static var compensator, IEEE Trans. on Power Syst., 7(1992), vol.2, 718-725.
  • [22] Han Y., Xu L., Averaged and switching function modelling for the active power filter with LCL-type coupling impedance, Przeglad Elektrot., 87(2011), n.4, 176-182.
  • [23] Han Y., Xu L., A survey of the smart grid technologies: background, motivation and practical applications, Przeglad Elektrot., 87(2011), n.6, 47-57.
  • [24] Grandi G., Rossi C., Ostojic D., Casadei D., A new multilevel conversion structure for grid-connected PV applications, IEEE Trans. Ind. Electron., 56(2009), n.11, 4416-4426.
  • [25] Han Y., Xu L., Khan MM, Yao G., Zhou L., Chen C., A novel synchronization scheme for grid-connected converters by using adaptive linear optimal filter based PLL (ALOF-PLL), Simul. Model. Pract. Theory, 17(2009), n.8, 1299-1345.
  • [26] Han Y., Xu L., Yao G., Zhou L., Khan MM., Chen C., State-Space Averaging (SSA) Technique for Modeling of the Cascaded H-Bridge Multilevel DSTATCOMs and Active Filters, International Review of Electrical Engineering-IREE, 4(2010), n.5, 744-760.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BPOH-0063-0008
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.