Electromagnetic field influence on implantable cardioverter defibrillator - reports review

Wybrane pełne teksty z tego czasopisma
Identyfikatory
Warianty tytułu
PL
Wpływ pola elektromagnetycznego na implantowane kardiowertery - defibrykatory - przegląd raportów badawczych
Języki publikacji
EN
Abstrakty
EN
The paper presents problems connected with implantable cardioverter-defibtrillators (ICDs) exposed to electromagnetic field. The authors have focused on several kinds of sources electromagnetic fields classified by ICDs manufacturers into three categories: unsafe (interference likely), need to take precaution (possible interference) and safe. There are a number of possible ICDs responses to external interference: temporary inhibition of the device or to inappropriate delivery of antitachycardia pacing and shocks.
PL
Praca prezentuje probematykę badań wszczepialnych kardiowerterów-defibrylatorów eksponowanych na sztucznie generowane pole elektromagnetyczne. Autorzy przedstawiają problem prawidłowej pracy tych urządzeń przy ekspozycji tych implantów na oddziaływanie źródeł pola elektromagnetycznego sklasyfikowanych przez producentów ICD jako: bezpieczne, bezpieczne przy zachowaniu środków ostrożnośc, niebezpieczne. Typowe zaburzenia pracy implantu eksponowanego na sztucznie wytworzone pole elektromagnetyczne opisane w doniesieniach literaturowych to: zaburzenia detekcji (migotania komór oraz częstoskurczu komorowego), zmiany w oprogramowaniu urządzenia, zatrzymanie generowania impulsów oraz niewłaściwe rozładowania źródeł zasilania.
Rocznik
Strony
121--122
Opis fizyczny
Bibliogr. 13 poz., rys., tab.
Twórcy
autor
  • University od Zielona Góra
Bibliografia
  • [1] International Electrotechnical Commission: Medical Electrical Equipment, Part 1: General Requirements for Safety. IEC Standard 601-1-2, 2001
  • [2] Implants for Surgery - Part 1: Implantable pacemakers - Committee Draft CD 5841-1 (draft 2 edition), International Organization for Standarization, Geneva, 2001
  • [3] Medtronic web page, www.medtronic.com
  • [4] Fetter JG et al., Digital cellular telephone interaction with implantable cardioverter-defibrillators, J Am Coli Cardiol., 1998 Mar 1,31, p. 623-8
  • [5] Occhetta E et al., Implantable cardioverter defibrillators and cellular phones: Is there any interference?, Pacing Clin Electrophysiol 1999, 22, p. 983-9
  • [6] Jimenez et al., Electromagnetic interference between automatic defibrillators and digital and analog cellular telephones, Rev Esp Cardiol, 1998, 51, p. 375-82
  • [7] Barbaro V et al., Electromagnetic interference of digital and analog cellular telephones with implantable cardioverter defibrillators: In vitro and in vivo studies, Pacing Clin Electrophysiol ,1999, 22, p. 626-634
  • [8] Roguin A et al., Modern Pacemaker and Implantable Cardioverter/Defibrillator Systems Can Be Magnetic Resonance Imaging Safe In Vitro and In Vivo Assessment of Safety and Function at 1.5 T, Circulation, 2004, p. 475-482
  • [9] Fetter JG, Benditt DG, Stanton MS, Electromagnetic interference from welding and motors on implantable cardioverter-defibrillators as tested in the electrically hostile work site, J Am Coli Cardiol., 1996, 28, p.423-7
  • [10] Kolb C, Schmieder S, Schmitt C, Inappropriate shock delivery due to interference between a washing machine and an implantable cardioverter defibrillator, J lnterv Card Electrophysiol., 2002, 7, p. 255-6
  • [11] Siu CW, Tse HF, Lau CP, Inappropriate implantable cardioverter defibrillator shock from a transcutaneous muscle stimulation device therapy, J lnterv Card Electrophysiol., 2005, 13, p. 73-5
  • [12] Biotronik web page, www.biotronik.com
  • [13] Giudant web page, www.guidant.com
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BPOF-0008-0027
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.