Calculation of SAR in biological object of different parameters

Autorzy
Wybrane pełne teksty z tego czasopisma
Identyfikatory
Warianty tytułu
PL
Obliczenia współczynnika SAR w obiektach biologicznych o różnych parametrach
Języki publikacji
EN
Abstrakty
EN
The paper aims at finding the influence of the body parameters on SAR in the biological object. The biological model that has been taken into account is a prolate spheroid. The spheroid is an isotropic lossy dielectric. The external medium was assumed to be free space. The excitation was a uniform plane wave. The calculations were carried out for the bodies with different parameters. The simulations were done for GSM frequency 900 MHz and 1800 MHz. The values of the SAR were calculated based on the calculating of the electric field strength distribution inside the body using semi-analytical method.
PL
W artykule bada się wpływ parametrów geometrycznych obiektu na współczynnik SAR w obiektach biologicznych znajdujących się w polu elektromagnetycznym. Model obiektu jest sferoidą ze stratnego dielektryka umieszczoną w próżni. Wymuszenie przyjęto jako falę płaską o częstotliwości 900 MHz i 1800 MHz. Obliczenia zostały wykonane metodą analityczną.
Rocznik
Strony
93--95
Opis fizyczny
Bibliogr. 7 poz., rys., tab.
Twórcy
autor
autor
  • Kielce University of Technology
Bibliografia
  • [1] Ciosk K., Krawczyk A., Kubacki R.: The influence of the electromagnetic wave parameters on SAR coefficient ISEF'05-lnternational Symposium, September 2005, Baiona, Spain
  • [2] Ciosk K., Krawczyk A: The influence of the electromagnetic wave frequency on SAR in biological object., EHE'06, Madeira, pp.2.97-2.100
  • [3] Ciosk K. at al., On SAR evaluation in the model of human head subjected to radiofrequency electromagnetic field, w: Electromagnetic fields in electrical engineering (ed. A. Krawczyk i S. Wiak), IOS Press, Amsterdam 2002.
  • [4] Ciosk K., Krawczyk A., Kubacki R.: Wyznaczanie współczynnika SAR w obiekcie biologicznym przy polaryzacji pionowej pola. Materiały konferencyjne XVII Sympozjum PTZE'2005, Ciechocinek
  • [5] Ciosk K., Krawczyk A., Kubacki R., The comparison of phantom model and simulation results in SAR analysis , in: Computer engineering in applied electromagnetism (ed. S. Wiak, A. Krawczyk, M. Trlep), Springer, 2005
  • [6] R. Kubacki at al., Comparison of numerical and measurement methods of SAR of ellipsoidal phantoms with muscle tissue electrical parameters, ISEF'05- International Symposium, September 2005, Baiona, Spain
  • [7] European Standard - EN50361, Basic standard for measurement of Specyfic Absorpiton Rate related to human exposure to electromagnefc fields from mobile phones (300MHz-3GHz) CENELEC July 2001
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BPOF-0008-0019
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.