Estimation of Rise Time of Discharge Current for Air Discharge of ESD-Gun with Low Charge Voltages

Autorzy
Wybrane pełne teksty z tego czasopisma
Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
With a 12-GHz digital oscilloscope, we measured discharge current waveforms for air discharges of an ESD-gun less than 1 kV onto a 50- [omega] SMA connector. To grasp real rise time of the observed waveforms, we reconstructed input current waveforms from complex frequency responses of the first and second order for the vertical amplifier of oscilloscopes, and estimated the rise time concerning them. As a result, we found that the frequency response measured for the oscilloscope agrees well with that of second order, which gives a minimum rise time of 27 ps at 300V.
PL
Wykorzystując cyfrowy oscyloskop o paśmie 12 GHz dokonano pomiarów kształtów prądów wyładowań elektrostatycznych w powietrzu przy poziomie napięcia na generatorze poniżej 1kV i przy obciążeniu 50 [omega]. W celu wyznaczenia rzeczywistego czasu narastania prądu zrekonstruowano jego kształt z zespolonej odpowiedzi częstotliwościowej pierwszego i drugiego rzędu w płaszczyźnie pionowej oscyloskopu. W rezultacie ustalono minimalny czas narastania prądu równy 27 ps dla napięcia 300V.
Rocznik
Strony
54--56
Opis fizyczny
Bibliogr. 8 poz., rys., wykr.
Twórcy
autor
autor
Bibliografia
  • [1] Takagi T., Research and development on EMC/EMI measurements and technologies in Japan, Trans. IEICE, Vol. J79-B-II (1996), No.11, 718-726 (in Japanese)
  • [2] Honda M., EMI aspects of the metal-metal ESD to the electronic equipment, J. IEICE, Vol.78 (1995), No.9, 849-850 (in Japanese)
  • [3] IEC 61000-4-2, Edition 2.0 (2008)
  • [4] Mori I., Fujiwara O. and Ishigami S., Rise time limit of discharge current for air discharge of an ESD-gun, Proc. of the fourth Asia-Pacific Conference on Environmental Electromagnetics, CEEM’2006, Vol.1, Dalian, China (2006), 34-37
  • [5] Agilent technologies, Understanding socilloscope frequency response and its effect on rise time, Agilent Note No.1420 (2003), 1-8 (in Japanese).
  • [6] Mori I., Taka Y., Fujiwara O. and Ishigami S., Chaacteristic comparison of discharge current caused by electrostatic discharge gun for the IEC immunity testinig, IEIEC Trans. COMMUN., Vol. J88-B (2005), No.12, 2401-2403 (in Japanese)
  • [7] Mittermayer C. and Steininger A., On the determination of dynamic errors for rise time measurement with an oscilloscope, IEEE Trans. On Instrumentation and Measurment, Vol.48 (1999), No.6, 1103-1107
  • [8] Sroka, J., Oscilloscope influence on the calibration uncertainty of the pulse rise time of ESD simulators”, Proc. IEEE International Symposium on EMC (2003), 378-381
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BPOD-0016-0014
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.