Distant Electric Field Caused by Cloud to Ground Lightning

Wybrane pełne teksty z tego czasopisma
Identyfikatory
Warianty tytułu
PL
Pola elektryczne pierwszego i kolejnego piorunowego wyładowania głównego zarejestrowane w trakcie burzy
Języki publikacji
EN
Abstrakty
EN
In the paper we show the fine structure of distant electric field waveforms caused by first and subsequent lightning return strokes measured during summer thunderstorms near Warsaw in Poland. A conception based on two current waves generated in attachment point is used in order to explain sharp peaks registered within the front of electric field. From obtained computer simulations one can infer that current wave speed between the attachment point and the channel base, should be less than current wave speed usually assumed in lightning study.
PL
W artykule zaprezentowano przebiegi czasowe pola elektrycznego pierwszego i kolejnego piorunowego wyładowania głównego zarejestrowane w trakcie burzy w pobliżu Warszawy. W trakcie modelowania matematycznego czoła tych przebiegów wykorzystano koncepcję linii transmisyjnej, wzdłuż której rozchodzi się fala prądowa generowana w punkcie połączenia się lidera odgórnego z liderem oddolnym.
Rocznik
Strony
51--53
Opis fizyczny
Bibliogr. 8 poz., rys., wykr.
Twórcy
autor
autor
Bibliografia
  • [1] Barański P., Michnowski S., Masłowski G., Gajda W.: Signatures of electric field changes associated with the continuing current stage of cloud-to-ground flashes, 13-th International Conference on Atmospheric Electricity ICAE 2007, Beijing, China, 13-17.08 2007
  • [2] Maslowski G., Baranski, P.: Examination of the slow front and fast transition in electric field waveforms produced by first and subsequent lightning strokes detected during summer thunderstorms near Warsaw, 3rd International Symposium on Lightning Physics and Effects, COST P18, April 14-15, 2008 Vienna, Austria.
  • [3] Lin Y.T., Uman M.A., Tiller J.A., Brantley R.D., Beasley W.H., Krider E.P., Weidman C.D.: Characterization of lightning return stroke electric and magnetic fields from simultaneous twostation measurements. J. Geophys. Res. 84, 1979, pp. 6307-14
  • [4] Jerauld J., Uman M.A., Rakov V.A., Rambo K.J., Jordan D.M., Schnetzer G.H.: The Slow Front and Fast transition in Close Electric and Magnetic Field and Field-Derivative Waveforms Produced by First Strokes of Natural Lighning. Proceedings of 13-th International Conference on Atmospheric Electricity, ICAE2007, Beijing, vol. I, pp. 517-520, 2007
  • [5] Baum, C.E.: Properties of lightning-leader pulses. Lightning Electromagnetics, ed. R.L. Gardner, New York: Hemisphere, 1990, pp. 3-16
  • [6] Paul C.R.: Introduction to Electromagnetic Compatibility, Wiley–Interscience, New York 1992
  • [7] IEC Standard 62305-1 2003. Protection against lightning. Part 1: General Principles
  • [8] Metwally I.A., Heidler F.: Improvement of the Lightning Shielding Performance of Overhead Transmission Lines by Passive Shield Wires, IEEE Transaction on Electromagnetic Compatibility, Vol. 45, No. 2, May 2003
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BPOD-0016-0013
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.