Tytuł artykułu
Wybrane pełne teksty z tego czasopisma
Identyfikatory
Warianty tytułu
Badania efektywności ochrony czułych urządzeń zapewnianej przez urządzenia ograniczające przepięcia
Języki publikacji
Abstrakty
The operations of digital apparatus in the information and telecommunication systems can be influenced by impulsive current of direct and nearby lightning flashes. The aim of the paper is to investigate the typical problems of selection and installation of voltage limiting SPDs, which can affect its effectiveness. In this contribution several results obtained by laboratory tests are presented. Special focus was addressed to ascertain the influence of circuit configuration where SPD is installed for the protection of sensitive apparatus against lightning overvoltages.
Praca urządzeń cyfrowych systemów informatycznych, telekomunikacyjnych może być zaburzona poprzez uderzenia pioruna bezpośrednio w strukturę, bądź w wyniku pośredniego oddziaływania prądu piorunowego. Celem pracy jest przybliżenie typowych problemów dotyczących wyboru poziomu ochrony SPD ograniczającego napięcie, poprzez przedstawienie wpływu wybranych elementów konfiguracji chronionego układu.
Wydawca
Czasopismo
Rocznik
Tom
Strony
57--59
Opis fizyczny
Bibliogr. 6 poz., rys., wykr.
Twórcy
autor
autor
autor
autor
autor
autor
- University of Rome “La Sapienza”, Via Eudossiana 18, 00-184 Rome, t.kisielewicz@uniroma1.it
Bibliografia
- [1] T. Kisielewicz, F. Fiamingo, C. Mazzetti, B. Kuca, D. Krasowski: Influence of lightning overvoltage shape on SPD characteristics for telecommunications and signalling networks, EMD 2011, Białystok, Poland, 28-30 September 2011
- [2] IEC 62305-4, “Protection against lightning – Part 4: Electrical and electronic systems within the structures”, Ed.2 December 2010
- [3] D. Krasowski, T. Kisielewicz, B. Kuca, Z. Flisowski, F. Fiamingo, C. Mazzetti: On critical distance between an spd and protected appliance with respect to their voltage coordination, ICLP 2010, Cagliari, Italy, 13-17 September 2010
- [4] T. Kisielewicz, F. Fiamingo, C. Mazzetti, B. Kuca, Z. Flisowski: Selected problems of sensitive apparatus protection against lightning overvoltages by means of SPD, EMD 2011, Białystok, Poland, 28-30 September 2011
- [5] G.L. Amicucci, F. Fiamingo, M. Marzinotto, C. Mazzetti, G. B. Lo Piparo, Z. Flisowski: Protection against lightning overvoltages of electrical and electronic systems: evaluation of the protection distance of an SPD, ICLP 2004, September 2004, Avignon, France
- [6] G. L. Amicucci, F. Fiamingo, Z. Flisowski, G.B. Lo Piparo, C. Mazzetti: Surge protective devices for low voltage systems: practical approach for the protection distance evaluation, IEEE Power Tech, Lausanne (Switzerland), 1-5 July 2007
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BPOC-0060-0074