Identyfikatory
Warianty tytułu
Błąd niedopasowania w pomiarach zaburzeń promieniowanych w badaniu kompatybilności elektromagnetycznej
Języki publikacji
Abstrakty
Radiated disturbances by EMC testing are sensed with an antenna and transmitted via the 50[omega] coaxial path to the receiver. The recalculation factor between the receiver signal and the measurand is defined with neglecting mismatching. As a matter of course the mismatch error appears. It is not determined but estimated and built-in into the measurement uncertainty budget. Formulas for the mismatch error by the junction antenna-receiver and with the inserted path are derived. Two approaches to estimation of the mismatch error in the bands C and D in the frequency range from 30MHz to 1GHz: the first recommended in the document CISPR 16-4-2 and the second with the Monte Carlo method are presented and illustrated with the numerical calculations. Evidently the first approach is to pessimistic and gives vastly overestimated error.
Zaburzenia promieniowane w badaniach kompatybilności elektromagnetycznej mierzone są anteną połączonaą z miernikiem zaburzeń koncentrycznym torem pomiarowym o impedancji charakterystycznej 50�[omega]. Wspóczynnik przeliczeniowy sygnalu miernika na wielkość mierzoną anteną (mezurand) zdefiniowany jest z pominięciem niedopasowań w torze pomiarowym. Jest to jeden ze składników błędu pomiaru. Błędu tego nie da sie wyznaczy�ć w sposób deterministyczny. Jest on szacowany i wbudowany w bilans niepewno�ści pomiaru. Wyprowadzono wzory na dwa rodzaje błędu niedopasowania: dla bezpośredniego połączenia anteny z odbiornikiem oraz z wtrąconym torem pomiarowym. Estymacjeę błędu niedopasowania polecaną w dokumencie CISPR 16-4-2 oraz z wykorzystaniem metody Monte Carlo zilustrowano obliczeniami numercznymi dla pomiaru pola elektrycznego zaburze�ń promieniowanych w pasmach C i D, w przedziale częstotliwości od 30MHz do 1GHz. Podej�ście proponowne w dokumencie CISPR 16-4-2 jest zbyt pesymistyczne i prowadzi do znacznego przeszacowania błędu.
Wydawca
Czasopismo
Rocznik
Tom
Strony
92--95
Opis fizyczny
Bibliogr. 6 poz., rys., tab., wykr.
Twórcy
autor
- EMC-Testcenter Zürich AG, Schaffhauserstr. 580, 8052-Zürich, Switzerland, j.sroka@emc-testcenter.com
Bibliografia
- [1] CISPR 16-4-2: 2003, Specification for radio disturbance and immunity measuring apparatus and methods - Part 4-2: Uncertainties, statistics and limit modeling - Measurement instrumentation uncertainty. IEC, 2003.
- [2] J. Sroka, Measurement Uncertainty in EMC Testing, Radio- Frequency Emission. OWPW, Monography, 2009.
- [3] R. Babka, Uncertainty of conducted emission measurements in EMC . Warsaw University of Technology, Dissertation, 2009.
- [4] Joint Committee for Guides in Metrology (JCGM), Evaluation of measurement data - Supplement 1 to the "Guide to the expression of uncertainty in measurement" - Propagation of distributions using a Monte Carlo method. JCMG 101:2008. Freely available at OIML web side, www.oiml.org.
- [5] C.,F.,M. Carobbi, The GUM Supplement 1 and the Uncertainty Evaluations of EMC Measurements . IEEE EMC Society Newsletter, Issue No. 225, 2010.
- [6] J. Sroka, Mismatch Correction by Measurement of Conducted Radio Disturbances With AMN . IEEE Trans. on EMC Vol. 53 No. 2 pp. 534 - 536, May, 2011.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BPOB-0050-0029