An identification of permanent magnet rotor position using a zero voltage vector method

Wybrane pełne teksty z tego czasopisma
Identyfikatory
Warianty tytułu
PL
Identyfikacja położenia wirnika silnika z magnesami trwałymi z wykorzystaniem metody zerowego wektora napięcia
Języki publikacji
EN
Abstrakty
EN
The paper describes a simple method of poles position identification of a permanent magnet motor. The method is related to impact of a back electromotive force on current shape produced when a zero voltage vector is applied. The method fulfils a gap between method for initial position detecting e.g. PIPCRM and simple back electromotive force estimation method. There are presented basis of the zero voltage vector method and laboratory results of method applied on 40 kVA axial flux permanent magnet motor in the paper.
PL
W artykule opisano prostą metodę identyfikacji położenia biegunów wirnika silnika z magnesami trwałymi. Zasada działania metody opiera się na wpływie siły elektromotorycznej na kształt prądu w czasie, gdy zadawany jest zerowy wektor napięcia. Metoda wypełnia lukę pomiędzy metodami identyfikującymi spoczynkowe położenie wirnika np. PIPCRM a metodą estymacji siły elektromotorycznej. Artykuł przedstawia zasadę działania metody oraz wyniki badań laboratoryjnych przeprowadzonych na maszynie o polu osiowym z magnesami trwałymi o mocy 40kVA.
Rocznik
Strony
91--95
Opis fizyczny
Bibliogr. 9 poz., rys., schem.
Twórcy
autor
  • Politechnika Warszawska, Instytut Sterowania i Elektroniki Przemysłowej, Zakład Napędu Elektrycznego, ul. Koszykowa 75, 00-662 Warszawa, wisniewj@isep.pw.edu.pl
Bibliografia
  • [1] Zhaofeng Li, Kawamura A., Investigation on resolution of initial position estimation for IPMSM, 14th International Power Electronics and Motion Control Conference, EPE-PEMC 2010, pp. S12-29 - S12-33, Ohrid, Republic of Macedonia, 6-8 September 2010
  • [2] Brandstetter P., Francik O., Simonik P., AC drive with permanent magnet synchronous motor and sensorless control, 14th International Power Electronics and Motion Control Conference, EPE-PEMC 2010, pp. T2-66 - T2-71, Ohrid, Republic of Macedonia, 6-8 September 2010
  • [3] de M Fernandes E., Oliveira A.C., Jacobina C.B., Lima A.M.N., Comparison of HF signal injection methods for sensorless control of PM synchronous motors, Twenty-Fifth Annual IEEE Applied Power Electronics Conference and Exposition, APEC 2010, Palm Springs, CA, 21-25 February 2010
  • [4] Robeischl E., Schroedl M.: Optimized INFORM measurement sequence for sensorless PM synchronous motor drives with respect to minimum current distortion, IEEE Transactions on Industry Applications, Vol. 40, No. 2, pp. 591– 598, March/April 2004
  • [5] Wiśniewski J. , Koczara W., Control of Axial Flux Permanent Magnet Motor by the PIPCRM Method at Standstill and at Low Speed, 13th International Conference on Power Electronics and Motion Control, EPE-PEMC 2008, pp. 2254- 2260, Poznań, Poland, 1-3 September 2008
  • [6] Wiśniewski J., Koczara W., Sensorless Control of the Axial Flux Permanent Magnet Synchronous Motor at Standstill and at Low Speed, 6th International Conference-Workshop Compatibility and Power Electronics, CPE 2009, pp. 463-468, Badajoz, Spain, 20-22 May 2009
  • [7] Shen J. X., Iwasaki S., Sensorless Control of Ultrahigh- Speed PM Brushless Motor Using PLL and Third Harmonic Back EMF, IEEE Transactions on Industrial Electronics, Vol. 53, No. 2, pp. 421-428, April 2006
  • [8] Wiśniewski J., Koczara W., The Sensorless Rotor Position Identification and Low Speed Operation of the Axial Flux Permanent Magnet Motor Controlled by the Novel PIPCRM Method, IEEE 39th Power Electronics Specialists Conference, PESC 2008, pp. 1502-1507, Rhodes, Greece, 15- 19 June 2008
  • [9] Wiśniewski J., Koczara W., Sensorless Control of Axial Flux Permanent Magnet Motor at Standstill and at Low Speed, Electrical Review, ISSN 0033-2097, R. 85 No 7/2009, 177-181
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BPOB-0048-0018
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.