PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

Assessment of exposure to magnetic-field emission from ship’s power frequency converters

Autorzy
Wybrane pełne teksty z tego czasopisma
Identyfikatory
Warianty tytułu
PL
Ocena narażenia na działanie pola magnetycznego emitowanego przez przemienniki częstotliwości na statkach
Języki publikacji
EN
Abstrakty
EN
A measurement method of non-stationary magnetic-field emissions from the ship's electric motor drive with the frequency converter is described. In a special case of simultaneous exposure to multiple frequency fields the level of the magnetic field intensity was evaluated, in reference to the standards, which take into account people protection against the excessive emission of a low-frequency magnetic field. Selected results of the off-line analysis of the recorded signals of magnetic field of ship bow thrusters drive with frequency converter are presented.
PL
Przedstawiono metodę oceny poziomu ekspozycji na niestacjonarne pole magnetyczne, pochodzące od okrętowego napędu elektrycznego z przekształtnikami częstotliwości. Określono wartości dopuszczalnej ekspozycji na pole magnetyczne o złożonym widmie w odniesieniu do zaleceń dotyczących ochrony zdrowia ludzkiego. Przedstawiono przykładowe wyniki analiz zarejestrowanych przebiegów czasowych indukcji magnetycznej w otoczeniu steru strumieniowego zasilanego z przemiennika częstotliwości.
Rocznik
Strony
257--261
Opis fizyczny
Bibliogr. 14 poz., il., tab., wykr.
Twórcy
Bibliografia
  • [1] Pałczyńska B., Spiralski L., Wyszkowski J., Electromagnetic Field Measurement of Bow Thruster Driver with Frequency Converter, Conference Proceedings of IEEE 5th International Conference-Workshop Compatibility in Power Electronics, Gdynia (2007), IEEE Catalog Number 07EX1712C, Library of Congress.
  • [2] Bassett C. A. L., Pulsing electromagnetic fields: A new method to modify cell behavior in calcified and noncalcified tissues, Calcif. Tissue Int., vol. 34 (1982), no. 1, pp. 1–8.
  • [3] Liboff A., Time-varying magnetic fields: Effect on DNA synthesis, Science, vol. 223 (1984), no. 4638, pp. 818–820.
  • [4] Habash R., Electromagnetic Fields and Radiation: Human Bioeffects and Safety, New York: Marcel Dekker, 2001, pp. 65–123.
  • [5] MIL STD 461E, Requirements for the control of Electromagnetic Interference Characteristics of Subsystems and Equipment”, 1999-08.
  • [6] ICNIRP guidelines for limiting exposure to time-varying electric, magnetic and electromagnetic fields (up to 300 GHz), Health Phys., vol. 74 (1988), no. 4, pp. 494–522.
  • [7] Bellan D., A. Gaggelli, Maradei F., Mariscotti A., Pignari A. S., Time-domain measurement and spectral analysis of nonstationary low-frequency magnetic-field emissions on board of rolling stock, IEEE Transactions on Electromagnetic Compatibility, vol. 46, no 1, February 2004. pp. 12-23.
  • [8] Mariscotti A., Measurement procedures and uncertainty evaluation for electromagnetic radiated emissions from large-power electrical machinery”, IEEE Transactions on Instrumentation and Measurement, vol. 56, No. 6, December 2007, pp. 2452–2462.
  • [9] 3D H/E fieldmeter ESM-100 Maschek, Technical Publication, Maschek Elektronik Germany, 2001.
  • [10] Microdrive Brochure MFO-250, PDL Electronics Ltd. (online available: http://www.pdlelectronics.com).
  • [11] Cohen L., Time –frequency analysis, Practice Hall Inc., New Jersey, 1995.
  • [12] Allen R. L., Mills D. W., Signal analysis. Time, frequency, scale, and structure, Willey-IEEE Press, 2004.
  • [13] LabVIEW – Advanced Signal Processing Toolkit - Time Frequency Analysis Tools. User Manual, National Instrument, 2005.
  • [14] Bendat J., S., Piersol A., G: Random data. Analysis and measurement procedures. New York Wiley, 2000.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BPOB-0023-0010
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.