PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

Influence of temperature on partial discharge characteristics in disc-void of oil/pressboard insulation

Autorzy
Wybrane pełne teksty z tego czasopisma
Identyfikatory
Warianty tytułu
PL
Wpływ temperatury na wyładowania niezupełne w izolacjach olejowych-preszpanowych
Języki publikacji
EN
Abstrakty
EN
Partial discharge based risk assessment method has rapidly developed as an effective diagnosis method in oil/pressboard insulation system. The temperature in field power transformer is variable according to loading and the PD properties in insulation are also variable in different temperature. In order to assess the influence of temperature on partial discharge properties in oil/pressboard insulation system, a partial discharge testing system with temperature adjusting function was adopted in this paper. The partial discharge data obtained from the experimental work were presented in phase-resolved PD (PRPD) pattern analysis and pulse sequence analysis (PSA). The single pulse in time domain at different temperature is also analysis in this paper.
PL
Wyładowania niezupełne staja się coraz powszechniejsza metoda diagnostyczną, szczególnie izolacji olejowych. Temperatura transformatorów energetycznych może się zmieniać w szerokich granicach zależnie od obciążenia i właściwości wyładowania niezupełnego też zależą od temperatury. Dlatego opracowano system umożliwiający badanie wyładowań niezupełnych w różnych temperaturach. Parametry wyładowań otrzymane w wyniku eksperymentów były poddane analizie graficznej (analiza wzoru - pattern analysis) jak i elektrycznej (analiza ciągu impulsów). Przedstawiono też analizę pojedynczego impulsu.
Rocznik
Strony
104--106
Opis fizyczny
Bibliogr. 10 poz., rys., tab., wykr.
Twórcy
autor
autor
autor
Bibliografia
  • [1] T.K.Saha, Z.T.Yao, D.J.T.Hill, G.Yeung, Investigating the Effects of Oxidation and Thermal Degradation on Electrical and Chemical Properties of Power Transformers Insulation, IEEE Trans. Power. Delivery. 14(1999), 1359-1367.
  • [2] M.K.Pradhan, T.S.Ramu. On the Estimation of Elapsed Life of Oil-immersed Power Transformers. IEEE Trans. Power. Delivery. 20(2005),1962-1969.
  • [3] Lutz Niemeyer. A Generalized Approach to Partial Discharge Modeling. IEEE Trans. Dielectrics Electr.2 (1995) 510-528.
  • [4] Xiaolin Chen, Yonghong Cheng, Bo Yue, Hengkun Xie. Study of epoxy/mica insulation deterioration in generator stator using ultra-wide band partial discharge testing technique. Polymer testing. 25(2006), 724-730.
  • [5] Choong-Sik Kim, Takeshi Kondo, Teruyoshi Mizutani. Change in PD Pattern with Aging. IEEE Trans. Dielectrics Electr. 11 (2004), 13-18.
  • [6] Kai Wu, Toshiro Ljichi, Takeyoshi Kato,Yasuo Suzuoki. Fumitaka Komori Tatsuki Okamoto. Contribution of Surface Conductivity to the Current Forms of Partial Discharges in Voids. IEEE Trans. Dielectrics Electr. 12(2005), 1116-1123.
  • [7] W.G.Ariastina, R.H.Khawaja. T.R.Blackburn. Investigation of Partial Discharge Properties in Oil-Impregnated Insulation. 8th International Conference on Properties and applications of Dielectric Materials, 2006.P:714 – 717
  • [8] R.Schifani, R.Candela and P.Romano. On PD Mechanisms at High Temperature in Voids Included in an Epoxy Resin. IEEE Trans. Dielectrics Electr. 8(2001), 589-597.
  • [9] A.Contin, G.C.Montanri and C.Ferraro. PD Source Recognition by Weibull Processing of Pulse Height Distributions. IEEE Trans. Dielectrics Electr. 7(2000), 48-57.
  • [10] Rainer Patsch and Farhad Berton. Pulse Sequence Analysis-a diagnostic tool based on the physics behind partial discharges. J.Phys.D:Appl.Phys.35(2002), 25-32.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BPOB-0021-0020
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.