Zero-sequence component and Harmonic Compensation in Four-wire Systems under Non-ideal Waveforms

Wybrane pełne teksty z tego czasopisma
Identyfikatory
Warianty tytułu
PL
Kompensacja składowej zerowej i zmniejszenie zawartości harmonicznych w układzie czteroprzewodowym
Języki publikacji
EN
Abstrakty
EN
The generalized theory of instantaneous powers has gained a great popularity in compensation of instantaneous powers and harmonic cancellation. This is practically true for three-phase systems as long as the load-terminal voltages remain balanced and sinusoidal. Nevertheless, for a three-phase four-wire system, when the power system is unbalanced or distorted, then these definitions introduce unsatisfactory cancellation of the source zero sequence current and harmonics suppression. This paper analyzes and simulates the aforesaid problem to show the issues concerned with the generalized theory of instantaneous powers. Further, complementary analytical discussions are suggested to remedy the raised problem. Finally, the improved definitions are simulated for a distorted and unbalanced three phase four-wire system. Comparing the complementary solutions with those of previously emerged generalized definitions confirms that the proposed solutions potentially provide a full cancellation of source-end zero sequence current as well as harmonics suppression under distorted and unbalanced load voltages.
PL
Ogólna teoria mocy chwilowej ma duże znaczenie przy kompensacji mocy chwilowych i eliminacji harmonicznych. Ta teoria jest prawdziwa dla systemów trzyfazowych jeśli napięcie obciążenia pozostaje zrównoważone i sinusoidalne. Jednak w systemach trzyfazowych, czteroprzewodowych te metody nie dają zadawalającej eliminacji prądu zerowego. W artykule przeanalizowano i zasymulowano powyższy problem dla pokazania niedostatków stosowania ogólnej teorii mocy chwilowej. Następnie zaproponowano rozwiązanie tych problemów. Wreszcie przedstawiono ulepszona definicję uwzględniającą system czteroprzewodowy. Wykazano, ze proponowany model umożliwia pełna kompensację prądu zerowego i zmniejszenie zawartości harmonicznych także dla obciążenia układu niezrównoważonego.
Rocznik
Strony
58--64
Opis fizyczny
Bibliogr. 18 poz., rys., schem., tab.
Twórcy
autor
  • Faculty of Electrical Engineering, K. N. Toosi University of Technology, Seid Khandan, P. O. Box 16315-1355, Tehran 16314-Iran, Pashajavid@ee.kntu.ac.ir
Bibliografia
  • [1] B. Singh, K. AL-Haddad, A. Chandra, A Review of Active Power Filters for Power Quality Improvement, IEEE Trans. On Industrial Electronics, 46 (1999), No. 5, 960-971
  • [2] F. Z. Peng and J. S. Lai, Generalized instantaneous reactive power theory for three-phase power systems, IEEE Trans. Instrum. Measurement, 45 (1996), No. 1, 293–297
  • [3] F. Z. Peng, George W. Ott, Jr. and Donald J. Adams, Generalized instantaneous reactive power theory for three-phase power systems, IEEE Trans. on Power Electronics, 13 (1998), No. 6, 1174-1181
  • [4] M. Tavakoli Bina, A New Complementary Approach to Inactive Power Compensation, Power Electron. Specialists Conf., PESC’03, IEEE 34th Annual, Electronic Record, June 2003, 1542-1547
  • [5] S. Fryze, Effective wattles and apparent power in electrical circuits for the case of non sinusoidal waveform of current and voltage, in elektrotechnische zeitschr., 53 (1932), 596-599
  • [6] L. Czarnecki, Minimization of Unbalanced and Reactive Currents in Three-Phase asymmetrical Circuits with Non-sinusoidal Voltage, IEE Proceedings-B, 139 (1992), No. 4, 347-354
  • [7] A.F. Zakeri, K. Kanzi, M. Tavakoli Bina, A New Approach to Compensation of Instantaneous Inactive power, Electric Machines & Drives Conference, IEMDC '07, Turkey, 2007, 624-629
  • [8] H. Akagi, Y. Kanazawa, A. Nabae, Generalized theory of the instantaneous reactive power in three-phase circuits, in IPEC’ 83- Int. Power Elec. Conf., Japan, 1983, 1375–1386
  • [9] H. Akagi, Y. Kanazawa. A. Nabae, Instantaneous reactive power compensators comprising switching devices without energy storage components, IEEE Trans. On Industrial Appl., IA-20 (1984), No. 3, 625-630
  • [10] H. Kim, F. Blaabjerg, B. Jensen, J. Choi, Instantaneous Power Compensation in Three-Phase Systems by Using p-q-r Theory, IEEE Trans. On Power Electronics, 17 (2002), No. 5, 701-710
  • [11] L.S. Czarnecki, Instantaneous reactive power p-q theory and power properties of three-phase systems, IEEE Trans. On Power Delivery, 21 (2006), No. 1, 362-367
  • [12] Jeon Seong-Jeub, Unification and Evaluation of the Instantaneous Reactive power Theories, IEEE Trans. Power Electronics, 23 (2008), No. 3, 1502-1510
  • [13] M. Aredes, J.Hafner, K. Heumann, Three-Phase Four-Wire Shunt Active Power Filter Control Strategies, IEEE Trans. On Power Electtronics, 12 (1997), No. 2, 311-318
  • [14] Gerardus C. Paap, Symmetrical Components in the Time Domain and Their Application to Power Network Calculations, IEEE Trans. On power systems, 15 (2000), No. 2, 522-528
  • [15] Bradaschia F., Arruda J. P., Souza H.E.P., Azevedo G.M.S., Neves F.A.S., Cavalcanti M.C., A Method for Extracting the Fundamental Frequency Positive-Sequence Voltage Vector Based on Simple Mathematical Transformations, IEEE Power Electron. Specialists Conf., PESC‘08, Greece, 2008, 1115-1121
  • [16] J. Holtz, Pulse width Modulation-A survey, IEEE Trans. On Industrial Elect., 39 (1992), No. 5, 410-420
  • [17] M. Tavakoli Bina, E. Pashajavid, An Efficient Procedure to Design Passive LCL-filters for Active Power Filters, Electr. Power Syst. Res., 79 (2009), No. 4, 606-614
  • [18] IEEE Recommended Practices and Requirements for harmonic Controls in Electric Power Systems, IEEE Stand. 519-1992, 1993
Typ dokumentu