The article presents the program spectral line method of module and phase errors correction in linear input circuits. The method requires the knowledge of the frequency characteristics of the module errors and the phase errors of the input circuit to be corrected. The method was used for frequency error correction of measurement transformers applied in electronic power transducers. Such input circuits are nonlinear and distort the measured signals. The article presents the analysis of the influence of the nonlinearity of the input circuits upon the effectiveness of correction of frequency errors of the input circuit module at measurements of the root-mean-square value.
PL
Przedstawiono programową metodę korekcji błędów częstotliwościowych liniowych obwodów wejściowych. Metodę zastosowano do korekcji błędów transformatorowych obwodów wejściowych stosowanych w elektronicznych przetwornikach pomiarowych. Przedstawiono analizę wpływu nieliniowości tego typu obwodów wejściowych na skuteczność korekcji błędów częstotliwościowych przy pomiarze wartości skutecznej.
Rocznik
Strony
257--260
Opis fizyczny
Bibliogr. 7 poz., wykr.
Twórcy
Bibliografia
  • [1] Furmankiewicz L., Possibility of software correction of errors introduced by transformer type input circuit of power transducers in distorted signal measurements, Ph.D. dissertation, Technical University of Zielona Góra, (1998), (unpublished).
  • [2] Furmankiewicz L., Using software as a method of correcting errors in power transducers, Electrical Power Quality and Utilization, vol. 5, (1999), no. 1, 31-35.
  • [3] Kadar L., Hacksel P., Wikston J., The effect of current and voltage transformers accuracy on harmonic measurements in electronic arc furnaces, IEEE Transactions on Industry Applications, vol. 33, (1997), no. 3, 780-783.
  • [4] Brittanii S., Cuzzolla F., Lotito F., Poncia G., Compensation of nonlinearities in a current transformer for the reconstruction of the primary current, IEEE Transactions on Control Systems Technology , vol. 9, (2001), no. 4, 565-573.
  • [5] Kłosiński R., Kozioł M., Reconstruction of periodic input signals by synthesis of inverse circular parametric operator of processing system, Pomiary Automatyka Kontrola, (2006), nr 6, 57-59.
  • [6] Bolikowski J., Czujniki prądu, Elektrotechnika Prądy Niesinusoidalne, VI Szkoła Konferencja. Zielona Góra, (2002), 181-192.
  • [7] Furmankiewicz L., Measurement of the frequency errors of input circuit using a complex voltage ratio measurement, Pomiary Automatyka Kontrola, vol 54, (2008), nr 6, 392-394.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BPOB-0015-0018
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.