PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

Full-scale bi-directional PSD testing of a torsionally unbalanced three-storey non-seismic RC frame structure: pre-test activity

Autorzy
Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
A research Project named SPEAR (Seismic Performance Assessment and Rehabilitation) is currently being carried out by a consortium of European Partners, with the participation of overseas research institutions. The Project, funded by the European Commission, is specifically aimed at mitigating the risk posed by seismically unsafe existing older RC and masonry frame buildings. In the framework of the SPEAR Project, pseudo-dynamic testing of a real size asymmetric 3-storey frame structure, before and after retrofitting, is being carried out. The data collected during the tests will be very useful to judge the effectiveness of analytical or Code-format models. This paper is focused on presenting the pre-test analytical work on the structure, consisting in two parts: 1) the application of current assessment procedures to the structure and 2) the analysis of the structure by means of numerical models with different levels of refinement. Moreover, the main features of the two-way pseudo-dynamic test are presented.
Rocznik
Tom
Strony
59--75
Opis fizyczny
Bibliogr. 14 poz., rys., tab., wykr.
Twórcy
autor
  • European Laboratory for Structural Assessment, Italy
autor
  • European Laboratory for Structural Assessment, Italy
Bibliografia
  • [1] ASCE-FEMA (2000) „Prestandard and commentary for the seismic rehabilitation of buildings”, FEMA 356
  • [2] ELNASHAI A.S., PAPANIKOLAOU V., LEE D-H. (2002) „ZeusNL User Manuał”, Mid-America Earthquake Center (MAE) Report
  • [3] EUROCODE 8 (2001): „Design of structures for earthquake resistance, Part 3: Strengthening and repair of buildings”, Doc CEN/TC250/SC8/N293, Draft No 1
  • [4] IZZUDDIN B.A., ELNASHA1 A.S. (1989) „ADAPTIC - a program for adaptive large displacement clastoplastic dynamie analysis of steel, concrete and composite frames”, Research Report ESEE Report No. 89/7, Imperial College, London
  • [5] JAPAN BUILDING DISASTER PREVENTION ASSOCIATION (1990) „Standards for seismic capacity evaluation of existing reinforced concrete buildings”, 1977 revised 1990 (in Japanese)
  • [6] JEONG S.H., ELNASIIAI A. (2003) „Analytical Assessment of the Seismic Performance of an Irregular RC Test Structure”, Preliminary Report, Department ofCivil and Environmental Engineering, University of Illinois at Urbana-Champaign Urbana, Illinois
  • [7] MANDER J.B., PRIESTLEY M.J.N., PARK R. (1988) „Thcoretical stress- strain model for confined concrete”, ASCE Journal of Structural Engineering, Vol. 1 14 No.8, pp. 1804-1826
  • [8] MOLINA F. J., VERZELETTI G„ MAGONETTE G., BUCI1ET P., GERADIN M. (1999) „Bi-directional pseudodynamic test of a full-size thrce-storey building”, Earthąuake Eng. Struct. Dyn., Vol.28, PP. 1541- 1566
  • [9] MWAFY A.M. (2001) „Seismic performance of code-designed RC buildings”, Ph.D. Thesis, Imperial College, University of London
  • [10] NEGRO P., MOLA E. (2002) „Currcnt assessment procedures: application to regular and irregular structures compared to cxperimental results” Proc. of 3rcl Workshop on the behaviour of Irregular and Complex Structures, Florence, September 2002
  • [11] NEGRO P., MOLA E. (2003) „Open problems in the design of irregular buildings”, Proc. of2"‘lSpecialty Conference on 'The conceptual approach to structural design ’, Milan, July 2003
  • [12] NEW ZEALAND NATIONAL SOCIETY FOR EARTHQUAKE ENGINEERING (2002) „The Assessment and improvement of the structural performance of earthquake risk buildings”, Draft 06 May 2002
  • [13] PINTO A.V., VERZELETT1 G„ MOLINA J„ VARUM H., PINHO R„ COELHO E. (2002) „Pscudo-dynamic tests on non-seismic rcsisting RC frames (bare and selective retrofit frames) ”, Report EUR 20244, European Commission, Joint Research Centre, IPSC, ELSA, Ispra, Italy
  • [14] PRIESILEY M.J.N., VERMA R., XIAO X., (1994) „Seismic shear strength of reinforced concrete columns”, J. of Struct. Eng., Vol.l20 No 8 PP.2310-2329
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BPOB-0008-0033
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.