PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

Assessment of airborne actinomycetes in subterranean and earth sanatoriums

Identyfikatory
Warianty tytułu
PL
Występowanie promieniowców w pomieszczeniu sanatoriów podziemnym oraz naziemnym
Języki publikacji
EN
Abstrakty
EN
Actinomycetes are common soil microorganisms; however, they have also been detected in air samples, becoming important air contaminants in occupational and residential habitats. Concentrations of airborne actinomycetes and their distribution among different fractions of bioaerosol were determined in selected sites of two sanatorium types, ie a subterranean located in the former salt-mine of Bochnia and standard earth spa of Szczawnica. The average concentrations of actinomycetes ranged from 0 to almost 40 cfu m-3, for the sanatorium of Bochnia, and from 7 to 125 cfu m-3, for Szczawnica spa, throughout the year. The respiratory fraction of the bioaerosol ranged from 25 to 51% and from 78 to 81% in the subterranean sites and rooms of Szczawnica spa, respectively. For both sanatoriums, among isolated actinomycetes dominated species belonging to Rhodococcus, Streptomyces and Nocardia. The results indicate that patients can be differentially exposed to airborne actinomycetes in compared sanatoriums. The air of underground spa reveals to be of better quality, regarding the bacteria characteristics.
PL
Promieniowce są pospolitymi mikroorganizmami glebowymi, które wykrywa się także w próbkach powietrza, gdzie stanowią istotne zanieczyszczenie środowiska pracowniczego oraz mieszkaniowego. w wybranych miejscach dwóch typów sanatoriów, podziemnego w byłej kopalni soli w Bochni oraz naziemnego w Szczawnicy, określano stężenie przenoszonych drogą powietrzną promieniowców oraz ich rozmieszczenie w różnych frakcjach bioaerozolu. Przeciętne stężenia promieniowców w ciągu roku w przypadku sanatorium w Bochni mieściły się w zakresie od 0 do 40 jtk m-3, a przypadku sanatorium w Szczawnicy między 7 a 125 jtk m-3. W pomieszczeniach podziemnego sanatorium w Bochni stężenie frakcji respirabilnej bioaerozolu wahało się między 25 a 51%, a w przypadku sanatorium w Szczawnicy wartość ta mieściła się między 78 a 81%. W oby typach sanatoriów wśród izolowanych promieniowców dominowały gatunki należące do Rhodococcus, Streptomyces oraz Nocardia. Otrzymane wyniki wykazują, że w porównywanych sanatoriach pacjenci mogą być w różnym stopniu narażeni na unoszące się w powietrzu promieniowce. Powietrze w podziemnym sanatorium okazało się być lepszej jakości pod względem przeprowadzonej charakterystyki mikrobiologicznej.
Rocznik
Strony
151--161
Opis fizyczny
Bibliogr. 60 poz., rys., tab.
Twórcy
autor
autor
  • Department of Microbiology, University of Agriculture, al. A. Mickiewicza 24/28, 30-058 Kraków, Poland, phone +48 12 662 41 81, rrfracze@cyf-kr.edu.pl
Bibliografia
  • [1] Kalakoutskii LV, Agre NS. Bacteriol Rev. 1976;40:469-524.
  • [2] Strap JL, Crawford DL. Ecology of Streptomyces in soil and rhizosphere. In: Cooper JD, Rao JR, editors. Molecular Approaches to Soil, Rhizosphere and Plant Microorganism Analysis. Wallingford:CAB Interantional; 2006:166-182.
  • [3] Górny RL. Ann Agric Environ Med. 2004;11:185-197.
  • [4] Reponen TA, Gazenko SV, Grinshpun SA, Willeke K, Cole E. Appl Environ Microbiol. 1998;64:3807-3812.
  • [5] Herr CEW, zur Nieden A, Jankofsky M, Stilianakis NI, Boedeker R-H, Eikmann TF. Occup Environ Med. 2003;60:336-342.
  • [6] Bünger J, Antlauf-Lammers M, Schulz TG, et al. Occup Environ Med. 2000;57:458-64.
  • [7] Poulsen OM, Breum NO, Ebbehoj N, et al. Sci Total Environ. 1995;168:33-56.
  • [8] Grigorevski-Lima AL, Silva-Filho RG, Linhares LF, Coelho RRR. Brasil Build Environ. 2006;41:1540-1543.
  • [9] Nevalainen A, Pasanen AL, Niininen M, Reponen T, Jantunen MJ, Kalliokoski P. Environ Int. 1991;17:299-302.
  • [10] Nevalainen A, Partanen P, Jääskeläinen E, Hyvärinen A, Koskinen O, Meklin T, Vahteristo M, Koivisto J, Husman T. Indoor Air. 1998;4:45-49.
  • [11] Walinder R, Norback D, Wessen B, Venge P. Arch Environ Health. 2001;56:30-6.
  • [12] Douwes J, Thorne P, Pearce N, Heederik D. Ann Occup Hyg. 2003;47:187-200.
  • [13] Hirsch SR, Sosman JA. Ann Allergy. 1976;36:30-38.
  • [14] Nevalainen A. Bacterial Aerosols in Indoor Air [PhD thesis]. Kuopio: National Public Health Institute; 1989.
  • [15] Kagen SL, Fink JN, Schlueter DP, Kurup VP, Fruchtman RB. J Allergy Clin Immunol. 1981;68:295-299.
  • [16] Minarik L, Dutkiewicz J, Umiński J. Med Wiejska. 1984;19:93-100.
  • [17] Skórska C, Mackiewicz B, Dutkiewicz J, Krysińska-Traczyk E, Milanowski J, Feltovich H, Lange J, Thorne PS. Ann Agric Environ Med. 1998;5:147-153.
  • [18] Burge H, Rogers C. Environ Health Perspect. 2000;108:653-659.
  • [19] Ross MA, Curtis L, Scheff PA, Hryhorczuk DO, Ramakrishnan V, Wadden RA, Persky VW. Allergy 2000;55:705-711.
  • [20] Salem H, Gardner D. Health aspects of bioaerosols. In: Lighthart B, Mohr A, editors. Atmospheric Microbial Aerosols. Theory and Applications. New York: Chapman & Hall; 1994:304-330.
  • [21] Lacey J, Dutkiewicz J. J Aerosol Sci. 1994;25:1371-1404.
  • [22] Huttunen K, Hyvärinen A, Nevalainen A, Komulainen H, Hirvonen M-R. Environ Health Perspect. 2003;111:85-92.
  • [23] Lighthart B. Physics of microbial bioaerosols. In: Lighthart B, Mohr AJ, editors. Atmospheric Microbial Aerosols. Theory and Applications. New York: Chapman & Hall; 1994:5-27.
  • [24] Green GE, Scarpino PV, Gibbs SG. Aerobiologia. 2003;19:159-169.
  • [25] Shelton B, Kirkland K, Elanders W, Morris G. Appl Environ Microbiol. 2002;68:1743-1753.
  • [26] Zhu H, Phelan PE, Duan T, Raupp GB, Fernando HJS, Ghe F. Aerobiologia. 2003;19:201-211.
  • [27] Mota LC, Gibbs SG, Green ChF, Payan F, Tarwater PM, Ortiz M. J Environ Health. 2008;70:48-53.
  • [28] Lee JH, Jo WK. Environ Res. 2006;101:11-17.
  • [29] Jones AM, Harrison RM. Sci Total Environ. 2004;326:151-180.
  • [30] Zhu H, Phelan P, Duan T, Raupp G, Fernando HJS. China Particuol. 2003;1:119-123.
  • [31] Wickman HH. Deposition, adhesion, and release of bioaerosols. In: Lighthart B, Mohr AJ, editors. Atmospheric Microbial Aerosols. Theory and Applications. New York: Chapman & Hall; 1994:99-165.
  • [32] Lynch JM, Poole NJ. Aerial dispersal and the development of microbial communities. In: Lynch JM, Poole NJ, editors. Microbial Ecology: A Conceptual Approach. New York: John Wiley & Sons; 1979:140-170.
  • [33] Salem H, Gardner DE. Health aspects of bioaerosols. In: Lighthart B, Mohr AJ, editors. Atmospheric Microbial Aerosols. Theory and Applications. New York: Chapman & Hall; 1994:304-330.
  • [34] Zeterberg JM. Ann Allergy. 1973;31:228-234.
  • [35] Hirvonen M-R, Nevalainen A, Makkonen N, Mönkkönen J, Savolainen K. Environ Toxicol Pharmacol. 1997;3:57-63.
  • [36] Jussila J, Komulainen H, Huttunen K, Roponen M, Hälinen A, Hyvärinen A, Kosma VM, Hirvonen M-R. Toxicol Appl Pharmacol. 2001;171:61-69.
  • [37] Greene VW, Vesley D, Bond RG, Michaelsen GS. Appl Microbiol. 1962;10:567-71.
  • [38] Stetzenbach LD. Introduction to aerobiology. In: Hurst ChJ, Knudsen GR, McInerney MJ, Stetzenbach LD, Walter MV, editors. Manual of Environmental Microbiology. Washington DC: ASM Press; 1997:619-628.
  • [39] Arlet G, Gluckman E, Gerber F, Perol Y, Hirsch A. J Hospit Infect. 1989;13:63-69.
  • [40] Streifel AJ, Vesley D, Rhame FS, Murray B. Environ Int. 1989;15:221-227.
  • [41] Eleftheriadis K, Halios CH, Petrakis M. Evaluation of indoor/outdoor aerosol and trace gas concentrations measured in the urban environment. Abstracts of EAC, Madrid: 2003;S1363-S1365.
  • [42] Kalogerakis N, Paschali D, Lekaditis V, Pantidou A, Eleftheriadis K, Lazaridis M. J Aerosol Sci. 2005;36:751-761.
  • [43] Koch AL. Microbiol Mol Biol Rev. 1997;61:305-318.
  • [44] Mulec J. Acta Carsol. 2008;37:153-160.
  • [45] Barton HA, Taylor NT, Kreate MP, Springer AC, Oehrle SA, Bertog JL. Int J Speleol. 2007;36:93-104.
  • [46] Groth I, Saiz-Jimenez C. Geomicrobiol J. 1999;16:1-8.
  • [47] Groth I, Saiz-Jimenez C. Coalition. 2002;4:12-14.
  • [48] Jurado V, Groth I, Gonzalez JM, Laiz L, Saiz-Jimenez C. Int J Syst Evolut Microbiol. 2005;55:153-157.
  • [49] Herold K, Gollmick FA, Groth I, Roth M, Menzel K-D, Möllmann U, Gräfe U, Hertweck C. Chemistry A Eur J. 2005;11:5523-5530.
  • [50] Iida S, Taniguchi H, Kageyama A, Yazawa K, Chibana H, Murata S, Nomura F, Kroppenstedt RM, Mikami Y. Int J Syst Evolut Microbiol. 2005;55:1871-1876.
  • [51] Blanc V, Dalle M, Markarian A, Debunne MV, Duplay E, Rodriguez-Nava V, Boiron P. J Clin Microbiol. 2007;45:1076-1077.
  • [52] Jurado V, Laiz L, Rodriguez-Nava V, Bairon P, Hermosin B, Sanchez-Moral S, Saiz-Jimenez C. Int J Speleol. 2010;39:15-24.
  • [53] Jurado V, Kroppenstedt RM, Saiz-Jimenez C, Klenk HP, Mouniee D, Laiz L, Couble A, Potter G, Boiron P, Rodriguez-Nava V. Int J Syst Evolut Microbiol. 2009;59:3105-3110.
  • [54] Atlas RM, Parks LC. Handbook of Microbiological Media. New York: CRC Press; 1997.
  • [55] Buchanan RE, Gibbons NE. Bergey’s Manual of Determinative Bacteriology. Baltimore: The Williams and Wilkins Co; 1974.
  • [56] Laiz L, Groth I, Gonzalez I, Saiz-Jimenez C. J Microbiol Methods. 1999;36:129-138.
  • [57] Li Ch-S, Hou P-A. Sci Total Environ. 2003;305:169-176.
  • [58] Wanner HU, Verhoeff H, Colombi A, Flanningan B, Gravesen S, Mouilleseaux A, Nevalainen A, Papadakis J, Seidel K. Report No 12. Biological particles in indoor environments. EUR 14988 EN.
  • [59] Beaman BL, Beaman L. Clin Microbiol Rev. 1994;7:213-64.
  • [60] Van den Bogart HGG, van den Ende G, van Loon PCC, van Griensven LJLD. Mycopathologia. 1993;122:21-8
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BPG8-0097-0012
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.