PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Powiadomienia systemowe
  • Sesja wygasła!
Tytuł artykułu

The study of electronic voltage transducers operation in conditions of dips and interruptions of measured voltage

Treść / Zawartość
Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
The aim of the paper is to present a response on dips and on interruptions of the measured voltage by means of electronic voltage transducers and inductive voltage transformers. Results of laboratory studies show high overvoltages generated in both a primary and secondary side of inductive VTs during the above mentioned conditions. Overvoltages in secondary circuits may damage measuring or protection apparatus connected to the secondary side of the VT. Using electronic voltage transducers enables users to avoid these problems.
Rocznik
Strony
645--649
Opis fizyczny
Bibliogr. 12 poz., rys., tab.
Twórcy
autor
autor
autor
  • Institute of Electrical Power Engineering, Technical University of Lodz, 18/22 Stefanowskiego St., 90-924 Łodź, Poland
Bibliografia
  • [1] EN 50160, Voltage Characteristics of Electricity Supplied byPublic Distribution Systems, CEN, 1999.
  • [2] R.C. Dugan, M.F. McGranaghan, S. Santoso, and H.W. Beaty, Electrical Power Systems Quality, McGraw-Hill, London, 2003.
  • [3] J. Schlabbach., D. Blume, and T. Stephanblome, Voltage Qualityin Electrical Power Systems, Ins. of Electrical Engineers, New York, 2001.
  • [4] E. Acha and M. Madrigal, Power Systems Harmonics; ComputerModelling and Analysis, Wiley&Sons Inc., London, 2002.
  • [5] R. Nowicz, Classical, Unconvetional and Special VoltageTransformers, Publishing House of Lodz Technical University, Łodź, 2003, (in Polish).
  • [6] M. Kaczmarek, D. Brodecki, and R. Nowicz, “Analysis of operation of voltage transformers during interruptions and dips of primary voltage”, Proc. Electrical Power Quality and Utilisation- EPQU 2009 1, CD-ROM (2010).
  • [7] M. Kaczmarek, “Transfer of interference by voltage transformers”, PhD Dissertation, Technical University of Lodz, Łodź, 2009, (in Polish).
  • [8] M. Kaczmarek and R. Nowicz, “Application of instrument transformers in power quality assessment”, Proc. Modern ElectricPower Systems - MEPS 2010 1, CD-ROM (2011).
  • [9] T.C. Schot, H. Blanchard, E.S. Popovic, R. Racz, and J. Husja, “High-accuracy analog Hall probe”, IEEE Trans. Ins. andMeas. 46 (2), 613-616 (1997).
  • [10] Z.L. Warsza, “Hallotron as a circuit element controlled by a magnetic field”, El. Rev. 83 (1), 57-64 (2007), (in Polish).
  • [11] A. Szczęsny, “Analysis of frequency properties of compensated current transformers” , PhD Dissertation, Technical University of Lodz, Łodź, 2007, (in Polish).
  • [12] IEC 61000-4-11, EMC. Testing and Measurement Techniques- Voltage Dips, Short Interruptions and Voltage Variations ImmunityTests, IEC, 2004. Bull.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BPG8-0096-0026
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.