System monitorowania linii kablowych i napowietrznych wysokich napięć

Treść / Zawartość
Identyfikatory
Warianty tytułu
EN
On – line system for cable and overhead high voltage lines
Konferencja
GDAŃSKIE DNI ELEKTRYKI’ 2011
Języki publikacji
PL
Abstrakty
EN
The monitoring of the temperature makes possible the introduced to exploitation system VALCAP of the NKT Cables company. The system measures the temperature along the conductor with the regard external temperature (only for overhead lines). The paper presents the applied in the practice method of the analysis of the acceptable load of cable or the conductor of the overhead line in dependence from stepping out external conditions.
Twórcy
autor
autor
autor
Bibliografia
  • 1. PN – E – 47000:1998 Wytyczne przeprowadzania pomontażowych badań odbiorczych.
  • 2. Olesz M.: Wpływ drzewienia elektrycznego na prądy polaryzacyjne i depolaryzacyjne w izolacji polietylenowej, X Sympozjum Problemy Eksploatacji Układów Izolacyjnych Wysokiego Napięcia, EUI ’05, Krynica 27-30.09.2005 r., Przegląd Elektrotechniczny, Konferencje, 2005, s. 193-196,
  • 3. Musiał E.: Obciążalność cieplna przewodów i kabli. Ogólnopolskie Szkolenie Techniczne „Zabezpiecze-nia niskonapięciowych instalacji i urządzeń elek-trycznych – cz. II” Poznań – Kiekrz, maj 2002. ENERGO-EKO-TECH. 2002, s. 1 -19
  • 4. IEC 60287-1:2006 Electric cables. Calculation of the current rating. Part 1. Current rating equations (100% load factor) and calculation of losses. Section 1 General. Section 2: Sheath eddy current loss factors for two circuits in flat formation Section 3. Current sharing between parallel single-core cables and calculation of circulating current losses
  • 5. IEC 60287-2-1:1994+A2:2006 Electric cables. Calculation of the current rating. Part 2: Thermal resistance. Section 1: Calculation of thermal resistance
  • 6. IEC 60287-2-2:1995 Electric cables - Calculation of the current rating - Part 2: Thermal resistance - Section 2: A method for calculating reduction factors for groups of cables in free air, protected from solar radiation
  • 7. IEC 60287-3-1:1999 Electric cables - Calculation of the current rating - Part 3-1: Sections on operating conditions - Reference operating conditions and selection of cable type
  • 8. IEC 60287-3-2: 1996 Electric cables - Calculation of the current rating - Part 3: Sections on operating conditions - Section 2: Economic optimization of power cable size
  • 9. IEC 60287-3-3:2007 Electric cables. Calculation of the current rating. Sections on operating conditions. Cables crossing external heat sources
  • 10. IEC 60853-1:2008 Calculation of the cyclic and emergency current rating of cables - Part 1: Cyclic rating factor for cables up to and including 18/30 (36) kV. Part 2: Cyclic rating of cables greater than 18/30 (36) kV and emergency ratings for cables of all voltages. Part 3: Cyclic rating factor for cables of all voltages, with partial drying of the soil