Influence of moisture on heat conductivity coefficient of aerated concrete

Identyfikatory
Warianty tytułu
PL
Wpływ wilgotności na współczynnik przewodnictwa cieplnego betonu komórkowego
Języki publikacji
EN
Abstrakty
EN
The article presents the experiment which determines moisture influence on aerated concrete heat conductivity parameter. Applied experimental setup consisted of two climatic chambers generating cold and hot temperatures on two sides of the sample which was equipped with necessary sensors to measure temperature, heat-flux and moisture. For moisture determinations the Time Domain Reflectometry technique was applied, which is currently developed method for moisture determinations of building materials and barriers. The result of the experiment was determination of heat conductivity coefficient of aerated concrete as a parameter which may be used in heat and moisture transport modeling in building barriers.
PL
Przedstawiono eksperymentalne badanie wpływu wzrostu wilgotności na współczynnik przewodnictwa cieplnego betonu komórkowego. Zastosowany zestaw pomiarowy składał się z dwóch komór klimatycznych generujących niskie i wysokie temperatury po przeciwnych stronach próbki wyposażonej w niezbędne czujniki do pomiaru temperatury, strumienia ciepła oraz wilgotności. Do pomiarów wilgotności zastosowano technikę TDR (Time Domain Reflectometry) - obecnie wdrażaną do pomiaru zawartości wody w materiałach i przegrodach budowlanych. Rezultatem opisanego eksperymentu jest wyznaczenie współczynnika przewodzenia ciepła betonu komórkowego w stanie suchym oraz w warunkach różnej wilgotności.
Rocznik
Strony
111--120
Opis fizyczny
Bibliogr. 12 poz., rys., tab.
Twórcy
autor
autor
  • Faculty of Environmental Engineering, Lublin University of Technology, ul. Nadbystrzycka 40B, 20-618 Lublin, tel. 81 538 43 22, tel. 81 538 44 81, H.Sobczuk@wis.pol.lublin.pl
Bibliografia
  • [1] Dyląg M. and Bień M.: Negatywne zjawiska związane z obecnością grzybów w pomieszczeniach zamkniętych (Negative phenomena connected with indoor presence of the mould), Mikol. Lek., 2006, 13(1), 49-54 (in Polish).
  • [2] Gawin D., Kosny J. and Desjarlais A.: Effect of moisture on thermal performance and energy efficiency of buildings with lightweight concrete walls. Proc. Summer Study on Energy Efficiency in Buildings Efficiency & Sustainability. Pacific Grove, California, USA, 2000, 149-160.
  • [3] Klemm P. (Ed.): Budownictwo ogólne (Civil Engineering). Tom 2, Fizyka budowli (Physics of Building). Arkady, Warszawa 2005 (in Polish).
  • [4] Sobczuk H., Suchorab Z., Kowal A. and Woroszyńska A.: Sprawozdanie z grantu KBN nr 4 T09 052 22 pt. Opracowanie modelu i zestawu pomiarowego do oceny charakterystyk cieplnych i wodnych materiałów budowlanych narażonych na oddziaływanie czynników klimatycznych w aspekcie ochrony środowiska (Report on the Scientific Polish Government Project No 4 T09 052 22: Elaboration of model and measurement setup for the valuation of heat and moisture characteristic of building materials prone to climate factors from the point of view of Environmental Protection), 2005 (in Polish).
  • [5] Roels S., Sermijn J. and Carmeliet J.: Modelling unsaturated moisture transport in autoclaved aerated concrete: microstructural approach, Proc. of the 6th Symposium on Building Physics in the Nordic Countries, Norwegian University of Science and Technology. Trondheim, Norway 2002, 167-174.
  • [6] http://www.solbet-lubartow.com.pl, March 2009.
  • [7] Hansen E.J. and Hansen M.H.: TDR measurement of moisture content in aerated concrete. Proc. of the 6th Symposium on Building Physics in the Nordic Countries. Norwegian University of Science and Technology, Trondheim, Norway 2002, 381-388.
  • [8] Sobczuk H. and Suchorab Z.: Calibration of TDR instruments for moisture measurement of aerated concrete. Proc. of Monitoring and Modelling the Properties of Soil as Porous Medium. Institute of Agrophysics. Polish Academy of Sciences, Lublin 2005, 158-165.
  • [9] Grunewald J.: Documentation of the Numerical Simulation Program DIM3.1, Volume 2, User’s Guide, 2000.
  • [10] Williams R.: Overview of the project to determine the thermal resistance of masonry walls in dry and moist states and a conversion procedure to determine the appropriate design value. Proc. of the 6th Symposium on Building Physics in the Nordic Countries. Norwegian University of Science and Technology, Trondheim, Norway, 2002, 539-546.
  • [11] Grunewald J., Plagge R. and Haupl P.: A two-leveled hygrotermal material database for the numerical simulation program DELPHIN4. Proc. of the 6th Symposium on Building Physics in the Nordic Countries. Norwegian University of Science and Technology, Trondheim, Norway, 2002, 39-46.
  • [12] Stefańska E.: Analiza czynników wpływających na zagrzybienie budynków (Analysis of the factors influencing mould presence in buildings). Proc. of Ekologia w inżynierii procesów budowlanych (Ecology in building processes engineering). Lublin - Kazimierz Dolny, Poland, 1998, 331-334 (in Polish).