A new scheme for power factor correction and active filtering for six-pulse converters loads

Wybrane pełne teksty z tego czasopisma
Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
This paper presents a novel harmonic-free power factor correction (PFC) topology based on T-type active power filter (APF), which is dedicated for power factor improvement and harmonic filtering for six-pulse converter loads. The cascaded controller structure is adopted for the proposed system, namely, the inner current loop and outer voltage loop. The current-loop control scheme is based on a decoupled state-space equations of the T-type APF using separate proportional-integral (PI) controllers in d-axis and q-axis of the synchronous rotating refer-ence frame (SRRF) synchronized with grid voltages, respectively. The fundamental components of load-side cur-rents are feed forwarded in the current-loop using two groups of synchronous frame adaptive linear neural networks (ADALINEs) to ensure estimation accuracy and a fast dynamic response. A separate proportional-integral (PI) controller is adopted in the outer voltage loop for balancing the active power flow of the voltage source inverter (VS I) dc-side capacitor. The experimental results confirm well with the theoretical analysis.
Rocznik
Strony
157--169
Opis fizyczny
Bibliogr. 28 poz., rys., tab.
Twórcy
autor
autor
autor
autor
autor
autor
Bibliografia
  • [1] J. Arrillaga, D.A Bradley, and J.e. McCall, Power System Harmonics, Wiley, New York, 1985.
  • [2] J.C. Das, "Passive filters-potentialities and limitations", IEEE Trans. Ind. Appl. 40 (1), 232-241 (2004).
  • [3] H. Fujita and H. Akagi, "A practical approach to harmonic compensation in power system - series connection of passive and active filters", IEEE Trans. Ind. Appl. 27 (6), 1020-1025(1991).
  • [4] Y.K. Lo, T.F. Pan, and J.M. Wang, "On setting the dc voltage level of an active power filter", Int. J. Circ. Theor. Appl. DOI 10.1002/cta.465, CD ROM (2007).
  • [5] H. Akagi "Control strategy and site selection of a shunt active filter for damping of harmonic propagation in power distribution systems", IEEE Trans. Power Deliv. 12 (I), 354-362 (1997).
  • [6] T.J. Park, G.Y. Jeong, and RH. Kwon, "Shunt active filter for reactive power compensation", Int. J. Electron. 88 (12), 1257-1269 (2001).
  • [7] F.Z. Peng, "Applied issues of active power filters", IEEE Ind. Appl. Mag. 4 (5), 21-30 (1998).
  • [8] H. Akagi, H. Fujita, and K. Wada, "A shunt active filter based on voltage detection for harmonic termination of a radial power distribution line", IEEE Trans. Ind. Appl. 35 (3), 638-M5 (1999).
  • [9] X.Q. Wu, C.K Tse, S.C. Wong, and J.N. Lu, "Fast-scale bifurcation in single-stage PFC power supplies operating with DCM boost stage and CCM forward stage", Int. J. Circ. Theor. Appl. 34 (3), 341-355 (2006).
  • [10] K.K. Law and K.W.E. Cheng, "Examination of the frequency modulation and lifting techniques for the generalized power factor correction switched-capacitor resonant converter", Int. J. Circ. Theor. Appl. DOI, 10.1002/cta.462, CD ROM (2007).
  • [11] H.J. Chiu, H.M. Huang, and H.T. Yang, S.J. Cheng, "An improved single-stage Flyback PFC converter for high-luminance lighting LED lamps", Int. J. Circ. Theor. Appl. 36, 205-210 (2008).
  • [12] R Mahanty, "A novel large value ac capacitor using two dc capacitors", Int. J. Cire. Theor. Appl. DOI, 10.1002/cta.484, CD ROM (2008).
  • [13] G.E. Pazienza, X. Ponce-Garcia, M. Balsi, and X. Vilasis-Cardona, "Robot vision with cellular neural networks, a practical implementation of new algorithms", Int. J. Circ. Theor. Appl. 35, 449-462 (2007).
  • [14] M. Forti, "M-matrices and global convergence of discontinuous neural networks", Int. J. Circ. Theor. Appl. 35 (2), 105-130 (2007).
  • [15] R.S. Gau, J.G.. Hsieh, and C.H. Lien, "Global exponential stability for uncertain bidirectional associative memory neural networks with multiple time-varying delays via LMI approach", Int. J. Circ. Theor. Appl. 36, 451-471 (2008).
  • [16] Z.K. Huang, S. Mohamad, X.H. Wang, and C.H. Feng, "Convergence analysis of general neural networks under almost periodic stimuli", Int. J. Cire. Theor. Appl.. DOI, 10.1002/cta.490, CD ROM (2008).
  • [17] F.Y. Chen, WH. Tang, and G..R Chen, "Single-layer perceptron and dynamic neuron implementing linearly nonseparable Boolean functions", Int. J. Circ. Theor. Appl. DOI, 10.1002/cta.481, CD ROM (2008).
  • [18] K. Satish, Neural Networks. A Classroom Approach, McGraw Hill, Columbus, 2005.
  • [19] S. Osowski, "Neural network for estimation of harmonic components in a power system", IEE Proeeedings-C 139 (2), 129-135 (1992).
  • [20] P.K. Dash, S.K Panda, R Mishra, and D.P. Swain, "Fast estimation of voltage and current phasors in power networks using an adaptive neural network", IEEE Trans. Power Syst. 12 (2), 1494-1499 (1997).
  • [21] L.L. Lai, W.L. Chan, C.T. Tse, and A.T.P. So, "Real-time frequency and harmonic evaluation using artificial neural networks", IEEE Trans. Power Deliv. 14 (1), 52-59 (1999).
  • [22] G.T.K. Abdel, E.I. SEF, and M.M.A. Salama, "Power quality event detection using Adaline", Electric Power Syst. Res. 64 (2), 137-144 (2003).
  • [23] R.E.I. Shatshat, M.M.A Salama, and M. Kazerani, "Artificial intelligent controller for current source converter-based modular active power filters", IEEE Trans. Power Deliv. 19 (3), 1314-1320 (2004).
  • [24] T.C. Green and J.H. Marks, "Control techniques for active power filters", IEE Proc.-Electrie Power Appl. 152 (2), 369-381 (2005).
  • [25] IEEE Std. 519-1992, Recommended Practices and Requirements for Harmonic Control in Electrical Power System, 1993.
  • [26] H. Akagi, "Active harmonic filters", Proc. IEEE 93 (12), 2128-2141 (2005).
  • [27] A. Bhowmik, A. Maitra, S.M. Halpin, and J.E. Schatz, "Determination of allowable penetration levels of distributed generation resources based on harmonic limit considerations", IEEE Trans. Power Deliv. 18 (2), 619-624 (2003).
  • [28] A. Maitra, S.M. Halpin, and C.A Litton, "Applications of harmonic limits at wholesale points of delivery", IEEE Trans. Power Deliv. 22 (1), 263-269 (2007).
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BPG5-0038-0035
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.