Tytuł artykułu
Autorzy
Wybrane pełne teksty z tego czasopisma
Identyfikatory
Warianty tytułu
Języki publikacji
Abstrakty
Unlike traditional passive filters, modem active filters have the following multiple func-tions; harmonic filtering, damping, isolation and termination, reactive-power control for power factor correction and voltage regulation, load balancing, voltage-flicker reduction, and/or their combinations. Significant cost reductions in both power semiconductor devi-ces and signal-processing devices have inspired manufactures to put active filters on the market. This paper deals with general pure active filters for power conditioning, and spe-cific hybrid active filters for harmonic filtering of three-phase diode rectifiers, as well as traditional passive filters.
Rocznik
Tom
Strony
255--269
Opis fizyczny
Bibliogr. 53 poz., 26 rys., 4 tab.
Twórcy
autor
- Department of Electrical and Electronic Engineering, Tokyo Institute of Technology 2-12-1 O-okayama, Meguro-ku, Tokyo, 152-8552, Japan, akagi@ee.titech.ac.jp
Bibliografia
- [1] B.M. Bird, J.F. Marsh, and P.R. McLellan, “Harmonic reduction in multiple converters by triple-frequency current injection”, IEEE Proc. 116 (10), 1730–1734 (1969).
- [2] H. Sasaki and T. Machida, “A new method to eliminate ac harmonic currents by magnetic compensation - consideration on basic design”, IEEE Trans. Power Appl. Syst. 90 (5), 2009–2019 (1971).
- [3] A. Ametani, “Harmonic reduction in thyristor converters by harmonic current injection”, IEEE Trans. Power Appl. Syst. 95 (2), 441–449 (1976).
- [4] L. Gyugi, and E.C. Strycula, “Active ac power filters”, IEEEIAS Ann. Meeting, 529–535 (1976).
- [5] N. Mohan, H.A. Peterson, W.F. Long, G.R. Dreifuerst, and J.J. Vithaythil, “Active filters for ac harmonic suppression”, IEEE/PES Winter Meeting, A77026–8, (1977).
- [6] I. Takahashi and A. Nabae, “Universal power distortion compensator of line-commutated thyristor converter”, IEEE-IAS Ann. Meeting, 858–864 (1980).
- [7] J. Uceda, F. Aldana, and P. Martinez, “Active filters for static power converters”, IEEE Proc. B 130 (5), 347–354 (1983).
- [8] H. Kawahira, T. Nakamura, S. Nakazawa, and M. Nomura, “Active power filter”, Conf. Rec. IEEJ-IPEC, 981–992 (1983).
- [9] H. Akagi, Y. Kanazawa, and A. Nabae, “Generalized theory of the instantaneous reactive power in three-phase circuits”, Conf. Rec. IEEJ-IPEC, 1375–1386 (1983).
- [10] H. Akagi, Y. Kanazawa, and A. Nabae, “Instantaneous reactive power compensators comprising switching devices without energy storage components”, IEEE Trans. Ind. Appl. 20 (3), 625–630 (1984).
- [11] H. Akagi, A. Nabae, and S. Atoh, “Control strategy of active power filters using voltage-source PWM converters”, IEEE Trans. Ind. Appl. 22 (3), 460–465 (1986).
- [12] H. Akagi, Y. Tsukamoto, and A. Nabae, “Analysis and design of an active power filter using quad-series voltage-source PWM converters”, IEEE Trans. Ind. Appl. 26 (1), 93–98 (1990).
- [13] F.Z. Peng, H. Akagi, and A. Nabae, “A study of active power filters using quad-series voltage-source PWM converters for harmonic compensation” IEEE Trans. Power Electron. 5 (1), 9–15 (1990).
- [14] S. Moran, “A line voltage regulator/conditioner for harmonicsensitive load isolation”, Conf. Rec. IEEE-IAS Ann. Meeting, 947–951 (1989).
- [15] W.M. Grady, M.J. Samotyj, and A.H. Noyola, “Survey of active power line conditioning methodologies”, IEEE Trans. Power Deliv. 5 (3), 1536–1542 (1990).
- [16] H. Akagi, “Trends in active power line conditioners”, IEEE Trans. Power Electron. 9 (3), 263–268 (1994).
- [17] H. Akagi, “New trends in active filters”, Conf. Rec. EPE 0, 17–26 (1995).
- [18] H. Akagi, “New trends in active filters for power conditioning”, IEEE Trans. Ind. Appl. 32 (6), 1312–1322 (1996).
- [19] B. Singh, K. Al-Haddad, and A. Chandra, “A review of active filters for power quality improvement”, IEEE Trans. Ind. Electron. 46 (6), 960–971 (1999).
- [20] F.Z. Peng, “Harmonic sources and filtering approaches”, IEEE Ind. Appl. Mag. 7, 18–25 (2001).
- [21] H. Akagi, “Active harmonic filters”, Proc. IEEE 93 (12), 2128–2141 (2005).
- [22] M. Routimo, M. Salo, and H. Tuusa, “Comparison of voltage source and current-source shunt active power filters”, Conf. Rec. 268 Bull. Pol. Ac.: Tech. 54(3) 2006 Modern active filters and traditional passive filters IEEE-PESC, 2571–2577 (2005).
- [23] A. Nakagima, J. Nishidai, and T. Shiraishi, “Development of active filter with series resonant circuit”, Conf. Rec. IEEE-PESC, 1168–1173 (1988).
- [24] F.Z. Peng, H. Akagi, and A. Nabae, “A new approach to harmonic compensation in power systems, a combined system of shunt passive and series active filters”, Conf. Rec. IEEE-IAS Ann. Meeting, 874–880 (1988), (IEEE Trans. Ind. Appl. 26 (6), 983–990 (1990)).
- [25] F.Z. Peng, H. Akagi, and A. Nabae, “Compensation characteristics of the combined system of shunt passive and series active filters”, IEEE Trans. Ind. Appl. 29 (1), 144–152 (1993).
- [26] H. Fujita and H. Akagi, “A practical approach to harmonic compensation in power systems: series connection of passive and active filters”, Conf. Rec. IEEE-IAS Ann. Meeting, 1107–1112 (1990), (IEEE Trans. Ind. Appl. 27 (6), 1020–1025 (1991)).
- [27] I. Takahashi, and Y. Omura, “High power active filter using LC tuned filter”, JIEE Trans. Ind. Appl. D 112 (9), 823–828 (1992), (in Japanese).
- [28] N. Tokuda, Y. Ogihara, M. Oshima, and T. Miyata, “Active filter with series L-C circuit”, Conf. Rec. IEEE-PES ICHPS, 242–249 (1994).
- [29] M. Rastogi, N. Mohan, and A.A. Edris, “Filtering of harmonic currents and damping of resonances in power systems with a hybrid-active filter”, Conf. Rec. IEEE-APEC, 607–612 (1995).
- [30] S. Bhattacharya, P.T. Cheng, and D.M. Divan, “Hybrid solutions for improving passive filter performance in high power applications”, IEEE Trans. Ind. Appl. 33 (3), 732–747 (1997).
- [31] D. Basic, V.S. Ramsden, and P.K. Muttik, “Harmonic filtering of high-power 12-pulse rectifier loads with a selective hybrid filter system”, IEEE Trans. Ind. Electron. 48 (6), 1118–1127 (2001).
- [32] D. Detjen, J. Jacobs, R.W. De Doncker, and H.G. Mall, “A new hybrid filter to dampen resonances and compensate harmonic currents in industrial power systems with power factor correction equipment”, IEEE Trans. Power Electron. 16 (6), 821–827 (2001).
- [33] B.N. Singh, B. Singh, A. Chanda, and K. Al-Haddad, “Digital implementation of a new type of hybrid filter with simplified control strategy”, Conf. Rec. IEEE-APEC, 642–648 (1999).
- [34] K. Oku, O. Nakamura, and K. Uemura, “Investigation into execution of harmonic guidelines for household and office electric applications”, IEE of Japan SC77A Domestic Committee Report, 7–9 (2002), (in Japanese).
- [35] K. Oku, O. Nakamura, and K. Uemura, “Measurement and analysis of harmonics in power distribution systems, and development of a harmonic suppression method”, IEE of Japan Trans. B 114 (3), 234–241 (1994), (in Japanese).
- [36] E.B. Makram, E.V. Subramaniam, A.A. Girgis, and R. Catoe, “Harmonic filter design using actual recored data”, IEEE Trans. Ind. Appl. 29 (6), 1176–1183 (1993).
- [37] D.A. Paice, Power Electronic Converter Harmonics: Multipulse Methods for Clean Power, Wiley-IEEE Press, 1995.
- [38] H. Akagi, “Control strategy and site selection of a shunt active filter for damping of harmonic propagation in power distribution systems”, IEEE Trans. Power Deliv. 12 (1), 354–363 (1997).
- [39] H. Akagi, H. Fujita, and K. Wada, “A shunt active filter based on voltage detection for harmonic termination of a radial power distribution line”, IEEE Trans. Ind. Appl. 35 (3), 638–645 (1999).
- [40] P. Jintakosonwit, H. Fujita, and H. Akagi, “Control and performance of a fully-digital-controlled shunt active filter for installation on a power distribution system”, IEEE Trans. Power Electron. 17 (1), 132–140 (2002).
- [41] P. Jintakosonwit, H. Akagi, H. Fujita, and S. Ogasawara, “Implementation and performance of automatic gain adjustment in a shunt active filter for harmonic damping throughout a power distribution system,” IEEE Trans. Power Electron. 17 (3), 438–447 (2002).
- [42] K. Wada, H. Fujita, and H. Akagi, “Considerations of a shunt active filter based on voltage detection for installation on a long distribution feeder”, IEEE Trans. Ind. Appl. 38 (4), 1123–1130 (2002).
- [43] P. Jintakosonwit, H. Fujita, H. Akagi, and S. Ogasawara, “Implementation and performance of cooperative control of shunt active filters for harmonic damping throughout a power distribution system”, IEEE Trans. Ind. Appl. 39 (2), 556–564 (2003).
- [44] S. Srianthumrong, H. Fujita, and H. Akagi, “Stability analysis of a series active filter integrated with a double-series diode rectifier”, IEEE Trans. Power Electron. 17 (1), 117–124 (2002).
- [45] N. Tsukamoto, H. Matsumura, S. Terama, N. Kawakami, and G. Tchouangue, “World-first 3.3kV/1.2kA IEGT in trench-gate technology”, Conf. Rec. PCIM, 270–274 (2004).
- [46] S. Srianthumrong and H. Akagi, “A medium-voltage transfor merless ac/dc power conversion system consisting of a diode rectifier and a shunt hybrid filter”, IEEE Trans. Ind. Appl. 39 (3), 874–882 (2003).
- [47] H. Akagi, S. Srianthumrong, and Y. Tamai, “Comparisons in circuit configuration and filtering performance between hybrid and pure shunt active filters”, Conf. Rec. IEEE-IAS Ann. Meeting, 1195–1202 (2003).
- [48] R.H. Baker, Bridge Converter Circuit, U.S. Patent 4270163, May 26, 1981.
- [49] A. Nabae, I. Takahashi, and H. Akagi, “A new neutral-pointclamped PWM inverter”, IEEE Trans. Ind. Appl. 17 (5), 518–523 (1981).
- [50] R. Teichmann and S. Bernet, “Three-level topologies for lowvoltage power converters in drives, traction and utility applications”, Conf. Rec. IEEE-IAS Ann. Meeting, 160–167 (2003).
- [51] T. Yoshida, M. Nishitoba, T. Ishikawa, and K. Tanaka, “Multifunctioned active filters complying with harmonic guidelines”, Meiden Review 248 (3), 28–32 (1996).
- [52] S. Ota, M. Tobita, and T. Yoshino, “New self-commutated SVC and SFC using IEGT”, Conf. Rec. IEEJ-IPEC, 2177–2181 (2005).
- [53] H. Akagi, “Large static converters for industry and utility applications”, Proc. IEEE 89 (6), 976–983 (2001).
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BPG5-0014-0082