PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

Fast tests in the service of a human being's environment

Autorzy
Identyfikatory
Warianty tytułu
PL
Szybkie testy w służbie środowiska człowieka
Języki publikacji
EN
Abstrakty
EN
A brief description of the design of basic fast tests bas been presented with particular consideration of dry tests. Basic methods of reading dry tests, both subjective and objective ones have been also described. Examples of applying fast tests for carrying out analysis under different conditions and in analytical matrices of various origin such as flood waters, mine waters, well water and natural water-courses and reservoirs, industrial wastewaters, fruit juices and finally milk have been also described. A good correlation of measurements carried out by means of the tests with the results of classical colorimetric measurements bas been shown. The high utility of fast tests for detecting and determining a number of ions and compounds where the rate of measurement is much more important than a very high precision bas been shown for selected examples. The examples presented have shown the usefulness of dry tests in various fields of a human being environment protection.
PL
W skrócie opisano podstawy budowy szybkich testów ze szczególnym uwzględnieniem testów suchych. Opisano również podstawowe sposoby odczytu testów suchych zarówno subiektywne, jak i obiektywne. Opisane zostały również przykłady wykorzystania szybkich testów do wykonywania analiz w różnych warunkach i w matrycach analitycznych bardzo różnego pochodzenia, takich jak: wody powodziowe, wody kopalniane, woda ze studni i naturalnych cieków i zbiorników, ścieki przemysłowe, soki owocowe i wreszcie mleko. Pokazano dobrą zgodność pomiarów wykonanych za pomocą testów z wynikami klasycznych pomiarów kolorymetrycznych. Na wybranych przykładach wykazano bardzo dużą użyteczność szybkich testów do wykrywania i oznaczania szeregu jonów i związków, gdzie ważniejsza jest szybkość pomiaru od bardzo dużej dokładności. Zaprezentowane przykłady pokazują przydatność szybkich testów w różnych dziedzinach ochrony środowiska człowieka.
Rocznik
Strony
1149--1166
Opis fizyczny
Bibliogr. 15 poz., rys., tab.
Twórcy
  • Institute of Biocybemetics and Biomedical Engineering, Polish Academy of Sciences, 02-109 Warszawa, ul Księcia Trojdena 4
Bibliografia
  • [1] Merck – Commerce information, Dramstadt 2003.
  • [2] Chwojnowski A. – Dry chemistry (in Polish), Exit, Warszawa 2003.
  • [3] Stratton N.J., Hirsch L., Harris F. et all.: Evoluation of the rapid Cleraview Chlamydia test for direct detection of chlamydia from cervical specimens. J. Clin. Microbiol. 1991, 29/7, 1551-1553.
  • [4] Merck – Rapid screening for drug of abuse; The laboratory in the “cassette” – Merck, informacja techniczna, Dramstadt 1995.
  • [5] Curme H.G., Columbus R.L., Dappen T.W. et. al.: Multilayer film elements for clinical analysis: General concepts. Clin. Chem. 1978, 24, 1335-1342.
  • [6] Columbus R.L. and Palmer H.J.: "Architextured" fluid Management of biological Liquids. Clin. Chem., 1987, 33, 1531-1537.
  • [7] Chwojnowski A., Dudziński K., Wojciechowski C. and Łukowska E.: Dry tests in environmental study. Selected problems and their solutions. Conference Analytical Forum 2004, Warszawa 8-10 July 2004;
  • [8] Chwojnowski A., Łukowska E. and Sabalińska A.: Application of reflectance reader of dry tests in analysis of flood water (in Polish). — Konferencja “Czujniki Optoelektroniczne i Elektroniczne” Poland, Jurata 1998, pp. 257-260.
  • [9] Chwojnowski A.: Dry tests in medicine and in environomental applications, MCB seminar "Electrochemical measuremeants of biological quantities", Warszawa 1995.
  • [10] Chwojnowski A., Łukowska E., Lewińska D. and Gruszczyński R.: Suche testy w problemach ochrony środowiska. Konferencja Naukowo-Techniczna "Ochrona Środowiska Terenów Górniczych". Krynica 1996, pp. 319-323.
  • [11] Chwojnowski A., Jaworowska-Deptuch H., Łukowska E. and Jaworska A.: Wykorzystanie suchych testów kolorymetrycznych w analizach biologicznych oczyszczalniach ścieków z galwanizerni. VI Konferencja Naukowa "Czujniki optoelektroniczne i elektroniczne", 13-16 czerwca 2000, pp. 331-338.
  • [12] Chwojnowski A., Dudziński K., Wojciechowski C. and Łukowska E.: Dry tests in environmental study. Selected problems and their solutions. Conference Analytical Forum 2004, Warszawa 8-10 July 2004.
  • [13] Łukowska E., Chwojnowski A., Dudziński K. and Wojciechowski C.: Quick test for determination of ascorbic acid in fruit and fruit-vegetable juices clear and unclear, preparing to print.
  • [14] Chwojnowski A., Łukowska E., Hryszczak L., Antolak R. and Dudziński K.: Oznaczenie krwi ukrytej w kale za pomocą gotowych zestawów diagnostycznych. XII Krajowa Konferencja Biocybernetyka i lnżynieria Biomedyczna 2001, Warszawa, vol. 1, pp. 227-231.
  • [15] Schroeder G.: Zastosowanie szybkich testów analitycznych w badaniach środowiskowych. Poznań 1998.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BPG5-0004-0037
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.