Residential indoor and outdoor air concentration of carbonyl compounds

Identyfikatory
Warianty tytułu
PL
Związki karbonylowe w powietrzu budynków mieszkalnych i poza nimi
Języki publikacji
EN
Abstrakty
EN
A study was undertaken in the Rome metropolitan area, in order to assess the residential indoor and outdoor (indoor/outdoor) air quality. Part of the study was aimed at checking the concentration levels of carbonyl compounds. Carbonyl compounds are of concern because of their adverse health effects. In this work, some measurements of carbonyl compounds in both indoor/outdoor air were performed in order to gain information on how to sample both residential apartments and related indoor/outdoor air. Simultaneous indoor/outdoor air samplings were carried out at 10 residential apartments, in the Rome urban area. Indoor carbonyl compounds were sampled in kitchen, living-room and apartment outdoor balcony using passive samplers. Formaldehyde, acetaldehyde, acetone + acrolein, propionaldeyde, benzaldehyde, n-butyraldehyde, isovaleraldehyde and valeraldehyde were measured and the obtained preliminary results confirm the findings of most studies reported by literature, the indoor air pollutants concentrations were much higher than the outdoor concentrations. Indoor sources of carbonyl compounds were deduced from the elementary descriptive statistics and pair wise Pearson correlation coefficients. The performed sampling method (a 10-day sampling) resulted in a fast and easy-to-use method that permits an immediate monitoring of indoor/outdoor compounds. However, for an in-depth study hourly, daily and weekly samplings should be performed, in order to support the interpretation of the results coming from analyses.
PL
Przedstawiono wyniki badań prowadzonych w Rzymie, których celem była ocena jakości powietrza w mieszkaniach i poza nimi. Część badań obejmowała analizy stężenia złożonych związków karbonylowych ze względu na ich negatywny wpływ na zdrowie człowieka Aby uzyskać informacje o sposobie pobierania próbek, który zapewniłby ich reprezentatywność, wykonano szereg pomiarów we wnętrzach pomieszczeń, jak i na zewnątrz. Równocześnie badania prowadzono w 10 mieszkaniach na terenach miejskich Rzymu. Próbki do badań pobierano z takich pomieszczeń, jak: kuchnia, pokój dzienny oraz z balkonu. Równocześnie badania prowadzono w 10 apartamentach na terenie Rzymu. W próbkach badano stężenie formaldehydu, acctaldchydu, acetonu i akroleiny, aldehydu propionowego, bcnzaldchydu, aldehydu n-butyrylowego, aldehydu izowalcrianowcgo i walerianowego. Wstępne wyniki potwierdzają wnioski większości badań opisanych w literaturze, gdzie opisuje się znacznie większe stężenie tych związków w pomieszczeniach zamkniętych niż w otwartym otoczeniu. Na podstawie obliczeń statystycznych można wysunąć wniosek o istnieniu źródeł zanieczyszczeń wewnątrz pomieszczeń. Zastosowany , sposób próbkowania (10-dniowe pobrania próbek) okazał się szybką i łatwą metodą monitorowania związków chemicznych w pomieszczeniach zamkniętych i poza nimi. Jednak, aby umożliwić pogłębioną interpretacje wyników analiz, konieczne są pobrania próbek w odstępach czasu: godzinnych, dniowych i tygodniowych.
Rocznik
Strony
47--56
Opis fizyczny
Bibliogr. 30 poz., rys., tab.
Twórcy
autor
autor
  • Istituto Superiore di Sanita, Dipartimento di Ambiente e Connessa Prevenzione Primaria, Viale Regina Elena 299-00161 Rome, I, tel. +48 39 064 99 02 995, +48 39 064 93 87 083, anna.santarsiero@iss.it
Bibliografia
  • [1] Commission of the European Communities. Communication from the Commission to the Council and the European Parliament on Thematic Strategy on the Urban Environment SEC(2006) 16.
  • [2] World Health Organization (WHO Regional Office for Europe, Copenhagen, Denmark, 2001) Air Quality Guidelines for Europe. Second Edition.
  • [3] International Agency for Research of Cancer (IARC). Formaldehydc, 2-Butoxy-cthnol and 1-tert-Butoxy-2-propanol. Available: http://monographs.iarc.fr/ENG/Meetings/88-1-tert-Butoxy-2-propanol. Last consultation 2006/10/09
  • [4] Carlier P., Hannachi H and Mouvicr G.: Atmos. Environ. 1986, 20, 2079-2099.
  • [5] Carter W.P.L.: Atmos. Environ. 1990, 24A, 481-518.
  • [6] Grosjean D.: Environ. Sci. Technol. 1991, 25, 710-715.
  • [7] Grosjean E., Grosjean D., Fraser M.P. and Cass G.R.: Environ. Sci. Technol. 1996, 30, 2687-2703.
  • [8] Williams LD., Revitt D.M. and Hamilton R.S.: Sci. Total Environ. 1996, 189/190, 475-483.
  • [9] Hileman, B.: Environ. Sci. Technol. 1984, 18, 216-225.
  • [10] Shepson P.B, Kleindienst T.E., Edney E.O., Nero C.M., Cupitt L.T. and Claxton L.D.: Environ. Sci. Technol. 1986, 20, 1008-1013.
  • [11] Bacz A.P., Belmont R. and Padilla H.: Environ Pollut. 1995, 89(2), 163-167.
  • [12] Granby K. and Christensen C.S.; Atmos. Environ. 1997, 31(10), 1403-1415.
  • [13] Godish T.: Am. J. Public Health. 1989, 79(8), 1044-1045.
  • [14] Possanzini M., Di Palo V., Petricca M., Fratarcangcli R. and Brocco D.: Atmos. Environ. 1996, 330(22), 3757-3764.
  • [15] Guo H., Mucray F, and Wilkinson S.: J. Air Waste Manage. Assoc. 2000, 50(2), 199-206.
  • [16] Guo H., Lcc S.C., Louie P.K,K. and Ho K.F.: Chemosphere 2004, 57(10), 1363-1372.
  • [17] Environmental Protection Agency (US EPA) Formaldehydc Carcinogcnity Assesment (II C) Avalable: http://www.epa.gov/iris/subst/0419.htm last consultation 2006110109.
  • [18] Index to EPA Test Methods, April 2003 revised edition. (Chemical Number index p. 10).
  • [19] Schwab M, Colomc S.D., Spengler J.D., Ryan P.B. and Billick I.H.: Toxicol. Ind. Health 1990, 6, 517-532.
  • [20] Ott W.L: Expos. Anal. Environ. Epidemiol. 1995, 5, 449-472.
  • [21] Grosjean E., Williams E.L., Grosjean, D.J.: Air & Waste Manage. Assoc. 1993. 43, 469-474.
  • [22] Humfrcy C., Shuker L. and Harrison P.: IEH Assessment on Indoor Air Quality in Home, Assessment A2; Medical Research Council, Institute for Environment and Health: Leicester, UK 1996.
  • [23] Maroni M., Scifcrt B. and Lindvall T.: Indoor Air Quality, A Comprehensive Reference Book; Elsevier Science: Amsterdam, The Netherlands, 1995, 3.
  • [24] Zhang J., He Q. and Lioy P.J.: Environ. Sci. Technol. 1994, 28, 146-152.
  • [25] Vainiotalo S. and Matveinen, K.: Am. Ind. Hyg. Assoc. J. 1993, 54, 376-332.
  • [26] Clarissc B., Laurent A.M., Seta N., Le Moullec Y., El Hasnaoui A. and Momas I.: Environ. Rcs. 2003, 92(3), 245-253.
  • [27] Haas Michiel E.: Caules and possible solution of indoor pollution. [In:] Proc. 8th Int. Svedala Symposium on Ecological Design. 1990.
  • [28] Raw, G.J.: Sick building syndrome. HSE CRR 1992, 42. Publisher, HSE Books.
  • [29] Mikho E.: World Hosp. Health Serv. 1994, 30(2), 26-30.
  • [30] Schneider P., Lörinci G., Gcbcfügi I.L., Heinrich J., Kettrup A. and Wichmann H.: J. Exp. Anal. Environ. Epidemiol. 1999, 9, 282-292.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BPG4-0025-0005
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.