PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

An attempt to apply fenton system in wastewater pretreatment from acetazolamide production

Autorzy
Identyfikatory
Warianty tytułu
PL
Próba zastosowania układu fentona w procesie podczyszczania ścieków z wytwarzania acetazolamidu
Języki publikacji
EN
Abstrakty
EN
The research was made on the possibility of pretreating wastewater from acetazolamide (2-acctyloaminc-1,3,4-thiadiazolc-5-sulphonamidc) production with the use of deep oxidation by the application of Fenton mixture. Optimal range of the reaction (pH), concentrations of iron(II) salts and hydrogen peroxide as well as their mutual molar proportions for which maximal COD reductions occurred were determined. Changes in the relations BOD5/COD, COD/N and BOD5/N were determined. It was found that the application of Fenton system significantly reduced COD and total suspended solids and eliminated color completely. The level of COD load depended on the quantity and the mutual proportions COD:Fe(II):H2O2. A high repeatability of the results and COD reduction more than 60 % were obtained for iron concentrations 500-2000 mg/dm3 with molar surplus of [H2O2] :[Fe(II)] - 2-10:1 and the reaction pH = 2.5-3.5. Within this range of reagents' concentrations, the distribution of COD reduction values correlated with the equation: COD = Ax3 - Bx2 + Cx - D(where: x=[H2O2] :[Fe(II)]). The method helped us consider possibilities of chemical pretreatment of wastewater from acetazolamide production and then a complete biological treatment by conventional methods.
PL
Przeprowadzono badania nad możliwością podczyszczania ścieków z produkcji acetazolamidu (2-acctylo-amino-1,3,4-tiadiazo-5-sulfonamid) z zastosowaniem głębokiego utleniania za pomocą mieszaniny Fentona. Wyznaczono optymalny zakres odczynu pH, stężeń soli żelaza(II) oraz nadtlenku wodoru, a także ich wzajemne proporcje molowe, dla których zachodziły maksymalne redukcje ładunku ChZT. Określono zamiany relacji BZT5/ChZT oraz ChZT/N i BZT5/N. Stwierdzono, że zastosowanie układu Fentona pozwala na dużą redukcję ChZT i zawiesin ogółem oraz pełną eliminację barwy. Poziom redukcji ładunku ChZT zależy od ilości i wzajemnych proporcji ChZT : Fe(II) : H202. Dla stężeń żelaza 500-2000 mg/dm3 przy nadmiarze molowym [H2O2] :[Fe(II)) - 2-10:1 i odczynie pH = 2.5-3.5 uzyskano bardzo dobrą powtarzalność wyników oraz redukcję ChZT, przekraczającą 60 %. W tym zakresie stężeń reagentów rozkład wartości redukcji ChZT korelował z równaniem postaci ChZT = Ax3 - Bx2 + Cx - D (gdzie: x=[H2O2] :[Fe(II)]). Metoda pozwala na rozwalenie możliwości wstępnego chemicznego podczyszczania ścieków z produkcji acetazolamidu a następnie pełnego biologicznego oczyszczania metodami konwencjonalnymi.
Rocznik
Strony
1133--1141
Opis fizyczny
Bibliogr. 16 poz., rys., tab.
Twórcy
autor
autor
  • Department of Technology and Chemical Engineering, University of Technology and Agriculture, Seminaryjna 3, 85-326 Bydgoszcz, zak@atr.bydgoszcz.pl
Bibliografia
  • [1] Ruffer H. and Rosenwinkel K..H.: Taschenbuch der Industrieabwasserreinigung, Oldenbourg Verlag, Munchen Wien 1991.
  • [2] Ruffer H.: Pharmazcutische Industrie, Lehr- und Handbuch der Abwasscrtechnik, Bd VI, 348 ff, Verlag Emst and Sohn, Berlin 1986.
  • [3] Kabdala I., Gurela M. and Tunaya O.: Pollution prevention and waste treatment in chemical synthesis processes for pharmaceutical industry, Water Sci. Technol., 1999, 39(10-11), 265-271.
  • [4] La Para T.M., Nakatsu C.H., Pantca L.M. and Alleman J.E.: Aerobic biological treatment of a pharmaceutical wastewater: effect of temperature on COD removal and bacterial community development, Water Res., 2001, 35(18), 4417-4425.
  • [5] Gulmez B., Ozturk L, Alp K. and Arikan O. A.: Common anaerobic treatabilily of pharmaceutical and yeast industry wastewater, Water Sci. Technol., 1998, 38(4-5), 37-44.
  • [6] Torres L.G., Jaimes J., Mijaylova P., Ramircz E. and Jimenez B.: Coagulation-flocculation pretreatment of high-load chemical-pharmaceutical industry wastewater: mixing aspects, Water Sci. Technol., 1997, 36(2-3), 255-262.
  • [7] Balclodlu I.A. and Otker M.: Treatment of pharmaceutical wastewater containing antibiotics by O3 and O3/H2O3 processes, Chemosphere, 2003, 50(1), 85-95.
  • [8] http://www.h2o2.com/applications/industrialwastewater.
  • [9] Wanpeng Z., Zhihua Y. and Li W.: Application of ferrous-hydrogen peroxide for treatment of H-acid manufactuńng process wastewater, Water Res., 1996, 30(12), 2949-2954.
  • [10] Kuo W.G.: Decolorizing dye wastewater with Fenton's reagent, Water Res., 1992, 26(7), 881-886.
  • [11] Oliveros W., Legrini O., Hohl M., Muller and Braun A.M.: Industrial waste water treatment: large scale development of light-enhanced Fenton reaction, Chem. Eng. Proc., 1997, 36, 397—405.
  • [12] Prousek J.: Advanced oxidation processes for water treatment. Chemical processes, Chem. Listy, 1996, 90, 229-237.
  • [13] Masten S.J. and Davies S.H.: Use of ozone and other strong oxidants for hazardous waste management, Advan. Environ. Sci. Technol., 1994, 28, 517-547.
  • [14] Walling C.: Fenton's reagent revisited, Acc. Chem. Res., 1997, 8, 125-131.
  • [15] Hermanowicz W., Dojlido J., Dożańska W., Koziorowski B. and Zerbe J.: Physical and chemical analysis of water and sewage [in Polish], Arkady Warszawa 1999.
  • [16] Talinli I. and Anderson G.K.: Interference of hydrogen peroxide on the standard COD test, Water Res., 1992, 26, 107-110.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BPG4-0019-0013
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.