The results of electrochemical treatment of model wastewater ate presented and compared. A sixelectrode (three cathodes and three anodes) electrolyzer with aluminum or iron electrodes, enabling optimum contact between the electrode surface and flowing wastewater, was applied in a recirculation system. The determinations of chemical oxygen demand (COD), suspended solids concentration, turbidity and color intensity show satisfactory treatability of model wastewater by electrocoagulation. It was found that iron electrodes are characterized by lower electric energy consumption than aluminum ones. A similar number of Al3+ and Fe3+ moles was needed to eliminate a similar pollutant load, which indicates that the mass of the optimum dose of an iron electrocoagulant is twice higher than the mass of the optimum dose of an aluminum electrocoagulant.
PL
W niniejszej pracy zestawiono i porównano wyniki elektrochemicznego oczyszczania ścieków modelowych. W układzie recyrkulacyjnym stosowano 6-elektrodowy (3 katody i 3 anody) elektrolizer z elektrodami aluminiowymi bądź żelaznymi, zapewniający bardzo dobry kontakt pomiędzy powierzchnią elektrod a przepływającymi ściekami. W rezultacie oznaczeń ChZT, mętności, zawiesin i barwy stwierdzono satysfakcjonującą podatność badanych ścieków modelowych na elektrokoagulację. Ustalono, że elektrody żelazne zapewniają mniejsze zużycie energii elektrycznej aniżeli aluminiowe. Zbliżone liczby moli Al3+ i Fe3+ usuwały podobne ilości zanieczyszczeń, umożliwiając stwierdzenie, że masa optymalnej dawki elektrokoagulantu żelazowego jest niemal dwukrotnie większa niż masa elektrokoagulantu glinowego.
Rocznik
Strony
1345--1354
Opis fizyczny
Bibliogr. 10 poz., rys., tab.
Twórcy
  • Chair of Chemistry, Faculty of EnviromIlent Shaping and Agriculture, University of Warmia and Mazury, Plac Łódzki 4, 10-957 Olsztyn, tel. 0/89/523 36 68, fax 0/89/524 04 08
Bibliografia
  • [1] Smoczyński L. And Groterud O.: Phosphorus removal from water by electrolysis. Water Res., 1986, 20(5), 667-669.
  • [2] Vik E.A. et al.: Electrocoagulation of potable water. Water Res., 1984, 18(11), 1355-1360.
  • [3] Rajesh R. S. et al.: Electrochemical treatment of cigarette industry wastewater: feasibility study. Water Res., 2002, 36(17), 4386-4390.
  • [4] Foyn E.: Etter 20 aar paa is: Tid for revurdering av den elektrolytiske renseprocess. Technisk Ukebald, 1980, 15a:4:48 (in Norwegian).
  • [5] Sheng H. Lin et al.: Saline wastewater treatment by electrochemical method. Water Res., 1998, 32(4), 1059-1066.
  • [6] Chen X. et al.: Separations of pollutants from restaurant wastewater by electrocoagulation. Sep. Purificat. Technol., 2000, 19, 65-76.
  • [7] Jia-Qian Jiang J.-Q. et al.: Laboratory study of electro-coagulation flotation for water treatment. Water Res., 2002, 36(16), 4064-4078.
  • [8] HACH DR /2000 Spectrophotometry Handbook, Procedure Manual., 1993.
  • [9] Hermanoowicz W. et al.: Fizykochemiczne badanie wody i ścieków, Arkady, Warszawa 1999.
  • [10] Ciardelli G. et al.: The treatment and reuse of wastewater in the textile industry by means of ozonation and electroflocculation. Water Res., 2001, 35(2), 567-572.