Tytuł artykułu
Wybrane pełne teksty z tego czasopisma
Identyfikatory
Warianty tytułu
Języki publikacji
Abstrakty
The present paper describes the results of tests on the influence of human saliva and its substitutes on tribological characteristics of implant materials on the example of the Ti-6Al-4V (a-Ti) titanium alloy. The saliva substitutes were prepared on the basis of pyrophosphates and mucins dissolved in saline buffer. The results of the presented tribological tests show that the values of the parameters under research varied from each other, while much similarity was observed between the evaluated level of wear characteristics after the friction process in the human saliva environment and that in the environment of one of the mucins tested. The microscopic observations of surfaces of the a-Ti samples after friction revealed varied forms of tribological wear. Infrared microspectroscopy studies of surfaces of the a-Ti samples after friction revealed the presence of secondary lubricating films based on mucin found in the artificial saliva solutions.
Czasopismo
Rocznik
Tom
Strony
71--79
Opis fizyczny
Bibliogr. 36 poz., rys., tab.
Twórcy
autor
autor
autor
autor
autor
autor
- Department of Materials and Biomedical Engineering, Białystok University of Technology
Bibliografia
- [1] SUROWSKA B., Biomateriały metalowe oraz połączenia metal–ceramika w zastosowaniach stomatologicznych, Wyd. Liber Duo s.c., Lublin 2009 (in Polish).
- [2] KOHN D.H., Metals in medical applications, Current Opinion in Solid State and Materials Science, 1998, 3(3), 309–316.
- [3] LONG M., RACK H.J., Review: Titanium alloys in total joint replacement – a materials science perspective, Biomaterials, 1998, 19, 1621–1639.
- [4] WANG K., The use of titanium for medical applications in the USA, Materials Science & Engineering A213, 1996, 134–137.
- [5] www.rhein83.com
- [6] DODDS M.W.J., JOHNSON D.A., YEHC Ch.-K., Health benefits of saliva: a review, J. Dent., 2005, 33, 223–233.
- [7] AMERONGEN A.V.N., VEERMAN E.C.I., Saliva – the defender of the oral cavity, Oral Diseases, 2002, 8(1), 12–22.
- [8] RANTONEN P., Salivary flow and composition in healthy and diseased adults, University of Helsinki, Helsinki, 2003.
- [9] BROSKY M.E., The role of saliva in oral health: strategies for prevention and management of xerostomia, J. Support. Oncol., 2007, 5(5), 215–225.
- [10] ZALEWSKA A. K., WASZKIEL D., KOWALCZYK A., Ślina jako główny składnik ekosystemu jamy ustnej, Wiad. Lek., 2007, 60, 3–4 (in Polish).
- [11] DE MATTIAS SARTORI I.A., RIBERIO R.F., FRANCISCHONE C.E., DE MATTOS M.G., In vitro comparative analysis of the fit of gold alloy or commercially pure titanium implant-supported prostheses before and after electroerosion, The Journal of Prosthetic Dentistry, 2004, Vol. 92, No. 3, 132–138.
- [12] KACZMAREK U., Leczenie suchości jamy ustnej – przegląd piśmiennictwa, Czas. Stomatol., 2007, LX, 2, 88–95 (in Polish).
- [13] DĄBROWSKI J. R., DEPTUŁA P., The effect of mechanic alloying on structure and properties of sintered Ti-Mo-Nb implant alloys, World Congress Powder Metallurgy, Florence, Italy, 2010.
- [14] IIJIMA D., YONEYAMA T., DOI H., HAMANAKA H., KUROSAKI N., Wear properties of Ti and Ti-6Al-7Nb castings for dental prostheses, Biomaterials, 24, 2003, 1519–1524.
- [15] OHKUBO C., SHIMURA I., AOKI T., HANATANI S., HOSOI T., HATTORI M., ODA Y., OKABE T., Wear resistance of experimental Ti-Cu alloys, Biomaterials, 24, 2003, 3377–3381.
- [16] LUO Y., GE S., Fretting wear behavior of nitrogen ion implanted titanium alloys in bovine serum lubrication, Tribology International, 42, 2009, 1373–1379.
- [17] NAUMANN D., FT-infrared and FT-Raman spectroscopy in biomedical research, Applied Spectroscopy Reviews, 2001, 36(2&3), 239–298.
- [18] STUART B., Biological Applications of infrared spectroscopy, Wiley & Sons, Chichester, 1997.
- [19] HUMECKI H. (ed.), Practical guide to infrared microspectroscopy, Marcel Dekker, Inc., New York, 1995.
- [20] ANDRYSEWICZ E., DĄBROWSKI J.R., LEONOW G., Aspekty metodyczne badań reologicznych śliny, Twój Prz. Stomatol., Z. temat., 2008, 10–15 (in Polish).
- [21] COHEN B.I., PAGNILLO M., CONDOS S., DEUTSCH A.S., Comparative study of two precision overdenture attachment designs, The Journal of Prosthetic Dentistry, 1996, 76, 145–152.
- [22] SETZ J., LEE S.H., ENGEL E., Retention of prefabricated attachments for implant stabilized overdentures in the edentulous mandible – an in vitro study, The Journal of Prosthetic Dentistry, 1998, 80, 323–329.
- [23] EPSTEIN D.D., EPSTEIN P.L., COHEN B.I., PAGNILLO M.K., Comparison of the retentive properties of six prefabricated post overdenture attachment systems, The Journal of Prosthetic Dentistry, 1999, 82, 579–584.
- [24] BUTTEL A.E., LUTHY H., SENDI P., MARINELLO C.P., Wear of ceramic and titanium ball attachments in subjects with an implant-retained overdenture-a controlled clinical trial, The Journal of Prosthetic Dentistry, 2012, 107, 109–113.
- [25] HATTON M.N., LOOMIS R.E., LEVINE M.J., TABAK L.A., Masticatory lubrication. The role of carbohydrate in the lubricating property of a salivary glycoprotein–albu-min complex, Biochem. J., 1985, 230, 817–820.
- [26] BERG C.H., LINDH L., ARNEBRANT T., Intraoral lubrication of PRP-1, statherin and mucin as studied by AFM, Biofouling, 2004, 20, 65–70.
- [27] BONGAERTS J.H.H., ROSSETTI D., STOKES J.R., The lubricating properties of human whole saliva, Tribol. Lett., 2007, 27, 277–287.
- [28] LI H., ZHOU Z.R., Wear behaviour of human teeth in dry and artificial saliva conditions, Wear, 2002, 249, 980–984.
- [29] MAYWORM C.D., CAMARG S.S., BASTIAN F.L., Influence of artificial saliva on abrasive wear and microhardness of dental composites filled with nanoparticles, Journal of Dentistry, 2008, 36, 703–710.
- [30] ZHENG J., ZHOU Z.R., Study of in vitro wear of human tooth enamel, Tribology Letters, 2007, Vol. 26, No. 2, 181–189.
- [31] SIVAKUMAR B., KUMAR S., NARAYANAN T.S.N.S., Fretting corrosion behaviour of Ti–6Al–4V alloy in artificial saliva containing varying concentrations of fluoride ions, Wear, 2011, 270, 317–324.
- [32] TURSSI C.P., FARAONO J.J., DE MENEZES M., SERRA M.G., Analysis of potential lubricants for In vitro wear testing, Dent. Mat., 2006, 22, 77–83.
- [33] VARDHANABHUTI B., COX P.W., NORTON I.T., FOEGEDING E.A., Lubricating properties of human whole saliva as affected by β-lactoglobulin, Food Hydrocolloids, 2011, 25, 1499–1506.
- [34] WOLF G., CRESPO J.G., REIS M.A.M., Optical and spectroscopic methods for biofilm examination and monitoring, Re/Views in Environmental Science & Bio/Technology, 2002, 1, 227–251.
- [35] YAO Y., GROGAN J., ZEHNDER M., LENDENMANN U., NAM B., WU Z., COSTELLO C.E., OPPENHEIM F.G., Compositional analysis of human acquired enamel pellicle by mass spectrometry, Archives of Oral Biology, 2001, 46, 293–303.
- [36] KOHAVI D, KLINGER A., STEINBERG D., SELA M.N., Adsorption of salivary proteins onto prosthetic titanium components, J. Prosthet. Dent., 1995, 74, 531–534.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BPBD-0003-0036