Influence of cementless cup surface on stability and bone fixation 2 years after total hip arthroplasty

Wybrane pełne teksty z tego czasopisma
Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
Loss of fixation between bone and implant surface is one of the main treatment problems in total hip arthroplasty. It might lead to implant instability, bone loss and treatment failure resulting in revision surgery. Surface modification is a method for improving bone response to implant and increasing implant osseointegration. However, the currently applied modifications such as hydroxyapatite coatings do not meet expectation and do not provide good clinical result. The object of the study was to evaluate the influence of acetabular cup surface modification on fixation and bone remodelling in total hip arthroplasty. Clinical and radiological outcomes were evaluated in patients two years after cementless total hip replacement. Two groups were compared: patients with acetabular component with uncoated titanium surface and patients with hydroxyapatite-coated acetabular surface. Hips X-rays were analysed for early signs of losing stability of acetabular cups. Two years after surgery the analysis of X-rays did not reveal any statistical differences in stability, migration of acetabular components of endoprosthesis between both groups. No differences were also observed in bone remodelling around implants. Particularly high percentage of cups, i.e. 17.64%, were classified into the group with high risk of early implant loosening, i.e., the group with HA coatings. Hydroxyapatite coatings on titanium cementless acetabular cups implanted by press-fit technique have no influence on their stability, bone-implant fixation and the remodelling of bone surrounding an implant two years after surgery.
Rocznik
Strony
27--35
Opis fizyczny
Bibliogr. 43 poz., rys., tab.
Twórcy
autor
autor
autor
autor
  • Department and Clinic of Orthopaedic and Traumatologic Surgery, Wrocław Medical University
Bibliografia
  • [1] HOZACK W., PARVIZI J., BENDER B. (ed.), Surgical treatment of hip arthritis: reconstruction, replacement and revision, 1st ed., Saunders, Elsevier, 2009.
  • [2] HARRIS W.H., Wear and periprosthetic osteolysis: the problem, Clinical Orthopaedics and Related Research, 2001, 393, 66–70.
  • [3] HERBERTS P., MALCHAU H., Long-term registration has improved the quality of hip replacement: a review of the Swedish THR Register comparing 160,000 cases, Acta Orthop. Scand., 2000, 71(2), 111–121.
  • [4] ROBERTSSON O., KNUTSON K., LEWOLD S., LIDGREN L., The Swedish Knee Arthroplasty Register 1975–1997: an update with special emphasis on 41,223 knees operated on in 1988–1997, Acta Orthop. Scand., 2001, 72(5), 503–513.
  • [5] MOOTANAH R., INGLE P., ALLEN E., CHEAH K., DOWELL J., JARRETT P., SHELTON J.C., Total Hip Replacement: Improving the Cement Fixation of the Acetabular Component, Proceedings of the 13th Conference of European Society of Biomechanics, Acta Bioeng. Biomech., 2002, 4, Supp. 1, 600–601.
  • [6] BRANEMARK P.J., HANSSON B.O., ADELL R., BREINE U., LINDSTRÖM J., HALLAN O., ÖHMAN A., Osseointegrated implants in the treatment of edentulous jaw, Stockholm, Almqvist and Wksell, 1977.
  • [7] SHEPPERD J.A.N., APTHORP H., A contemporary snapshot of the use of hydroxyapatite coating in orthopaedic surgery, J. Bone Joint Surg., Aug 2005, 87, 8.
  • [8] TONINO A.J., van der WAL B.C., HEYLIGERS I.C., GRIMM B., Bone remodeling and hydroxyapatite resorption in coated primary hip prostheses, Clin. Orthop. Relat. Res., 2009, 467, 478–484.
  • [9] CANALE S.T., BEATY J.H., Campbell’s Operative Orthopaedics, 11ed., Mosby, Elsevier, 2008.
  • [10] CALLAGHAN J.J., DYSART S.H., SAVORY C.G., The uncemented porous-coated anatomic total hip prosthesis. Twoyear results of a prospective consecutive series, J. Bone Joint Surg., (Am.) 1988, 70, 337–346.
  • [11] DORR L.D., ZHINIAN W., Ten Years Experience with Pourous Acetabular Components for Revision Surgery, Clinical Orthopaedics, 1995 October, Vol. 319.
  • [12] ILCHMANN T., FREEMAN M.A.R., MJOBERG B., Accuracy of the Nunn method in measuring acetabular cup migration, Uppsala, J. Med. Sci., 97, 67–68.
  • [13] SUTHERLAND C.J., WILDE A.H., BORDEN L.S., MARKS K.E., A ten-year follow-up of one hundred consecutive Muller curved-stem total hip-replacement arthroplasties, J. Bone Joint Surg., 1982, 64–A, 970–982.
  • [14] WETHERELL R.G., AMIS A.A., HEATLEY F.W., Measurement of acetabular erosion, J. Bone Joint Surg., 1989, 71-B, 447–451.
  • [15] ENGH C.A., BOBYN J.D., GLASSMAN A.H., Porous-coated hip replacement. The factors governing bone ingrowth, stress shielding, and clinical results, J. Bone and Joint Surg., 1987, 69-B(l), 45–55.
  • [16] MASSIN P., SCHMIDT L., ENGH C.A., Evaluation of cementless acetabular component migration. An experimental study, J. Arthroplasty, 1989, 4, 245.
  • [17] www.depuy.com (dostęp: 27 lipca 2011).
  • [18] http://www.bbraun.com (dostęp: 27 lipca 2011).
  • [19] http://www.stryker.com (dostęp: 07 sierpień 2011).
  • [20] http://www.biomet.com (dostęp: 08 sierpień 2011).
  • [21] SÖDERMAN P., MALCHAU H., Is the Harris hip score system useful to study the outcome of total hip replacement? Clin. Orthop. Relat. Res., 2001 Mar., 384, 189–197.
  • [22] MAHOMED N.N., ARNDT D.C., McGRORY B.J., HARRIS W.H., The Harris hip score: Comparison of patient self-report with surgeon assessment, The Journal of Arthroplasty, August 2001, 16(5), 575–580.
  • [23] DeLEE J.G., CHARNLEY J., Radiological demarcation of cemented sockets in total hip replacement, Clin. Orthop. Relat. Res., 1976 Nov–Dec, 121, 20–32.
  • [24] MANLEY M.T., CAPELLO W.N., D’ANTONIO J.A., EDIDIN A.A., GEESINK R.G., Fixation of acetabular cups without cement in total hip arthroplasty. A comparison of three different implant surfaces at a minimum duration of followup of five years, J. Bone Joint Surg. Am., 1998, 80(8), 1175–1185.
  • [25] BLOEBAUM R.D., LIAU D.W., LESTER K.D., ROSENBAUM T.G., Dual-energy X-ray absorptiometry measurement and accuracy of bone mineral after unilateral total hip arthroplasty, The Journal of Arthroplasty, 2006, 21(4).
  • [26] AKHAVAN S., MATTHIESEN M.M., SCHULTE L., PENOYAR T., KRAAY M.J., RIMNAC C.M., Clinical and histologic results related to a low-modulus composite total hip replacement stem, J. Bone Joint Surg., June 2006, 88-A(6).
  • [27] MENEGHINI R.M., FORD K.S., McCOLLOUGH C.H., HANSSEN A.D., LEWALLEN D.G., Bone remodeling around porous metal cementless acetabular components, The Journal of Arthroplasty, 2010, 25(5), 741–747.
  • [28] GARELLICK G., KÄRRHOLM J., ROGMARK C., HERBERTS P., Swedish Hip Arthroplasty Register Annual Report, 2008.
  • [29] STILLING M., RAHBEK O., SØBALLE K., Inferior survival of hydroxyapatite versus titanium-coated cups at 15 years, Clin. Orthop. Relat. Res., 2009, 467, 2872–2879.
  • [30] LAZARINIS S., KÄRRHOLM J., HAILER N.P., Increased risk of revision of acetabular cups coated with hydroxyapatite. A Swedish Hip Arthroplasty Register study involving 8,043 total hip replacements, Acta Orthopaedica, 2010, 81(1), 53–59.
  • [31] CAMAZZOLA D., HAMMOND T., GANDHI R., DAVEY J.R., A randomized trial of hydroxyapatite-coated femoral stems in total hip arthroplasty. A 13-year follow-up, The Journal of Arthroplasty, 2009, 24(1).
  • [32] LEE J.M., LEE C.W., Comparison of hydroxyapatite-coated and non-hydroxyapatite-coated noncemented total hip arthroplasty in same patients, The Journal of Arthroplasty, 2007, 22(7).
  • [33] VIDALAIN J.P., Corail stem long-term results based upon the 15-year artro group experience, [in:] Epinette J.A., Manley M.T. (ed.), Fifteen years of clinical experience with hydroxyapatite coatings in joint arthroplasty, Springer, France, 2004, p. 217.
  • [34] HAVELIN L.I., ESPEHAUG B., ENGESAETER L.B., The performance of two hydroxyapatite-coated acetabular cups compared with Charnley cups from the Norwegian Arthroplasty Register, J. Bone Joint Surg. [Br], 2002, 84-B, 839–845.
  • [35] BLACHA J., High osteolysis and revision rate with the hydroxyapatite- coated ABG hip prostheses: 65 hips in 56 young patients followed for 5–9 years, Acta Orthop. Scand., 2004, 75, 276–282.
  • [36] MORONI A., FALDINI C., PEGREFFI F., HOANG-KIM A., GIANNINI S., Hydroxyapatite coating of fixation devices for osteoporotic bone, J. Bone Joint Surg. [Br], 2005, 87-B, supp I, 55.
  • [37] PARK J., LAKES R.S., Biomaterials. An Introduction, third edition, Springer, 2007.
  • [38] PULEO D.A., BIZIOS R., Biological Interactions on Materials Surfaces Understanding and Controlling Protein, Cell and Tissue Responses, Springer, LLC 2009.
  • [39] JUNKER R., DIMAKIS A., THONEICK M., JANSEN J.A., Effects of implant surface coatings and composition on bone integration: a systematic review, Clin. Oral. Impl. Res., 2009, 20 (Suppl. 4), 185–206.
  • [40] BERRY D.J., STEINMANN S.P. (ed.), Adult Reconstruction, 1st ed., Williams & Wilkins, 2007.
  • [41] MASON J.B., The new demands by patients in the modern era of total joint arthroplasty. A point of view, Clin. Orthop. Relat. Res., 2008, 466, 146–152.
  • [42] WODZISŁAWSKI W., KRUPA S., NOWICKI J., BĘDZIŃSKI R., DETYNA J., The reaction of the pelvis to the implantation of the acetabular component of the hip endoprosthesis – initial tests with the use of computerized tomography, Acta Bioeng. Biomech., 2009, 11(4), 45–54.
  • [43] CHERNIAKOVA YU.M., PINCHUK L.S., Tribological aspects of joint intraaricular therapy, Acta Bioeng. Biomech., 2011, 13(1), 57–63.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BPBD-0003-0004
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.