PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Powiadomienia systemowe
  • Sesja wygasła!
Tytuł artykułu

The reaction of the pelvis to the implantation of the acetabular component of the hip endoprosthesis - initial tests with the use of computerized tomography

Wybrane pełne teksty z tego czasopisma
Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
Among the population over the age of 65 years joint diseases constitute more than 50% of chronic diseases and most often apply to the hip. Endoprosthetics is one of the methods for treating this condition and is considered one of the best - clinically and economically - interventions of the modern medicine. However, it is not free of complications among which the loosening of the endoprosthesis is commonest. In publications, a full discussion has been going on arguing whether the complication is caused by biological or mechanical factors. The authors - aiming to answer this question based on CT - tested the influence of the implantation of the acetabular component on the pelvic bone density in Hounsfield units within a 6-month period after the operation. The test results indicate the bone density decrease. The statistical analysis shows, however, that the changes are not statistically significant.
Rocznik
Strony
45--54
Opis fizyczny
Bibliogr. 31 poz., rys., tab.
Twórcy
autor
autor
autor
Bibliografia
  • [1] BĘDZIŃSKI R., Biomechanika inżynierska, Oficyna Wydawnicza Politechniki Wrocławskiej, Wrocław, 1997, 118–154.
  • [2] CALLAGHAN J.J., KIM S.Y., BROWN T.D., PEDERSEN D.R., JOHNSTON R.C., Concerns and improvements with cementless metal-backed acetabular components, Clin. Orthop., 1995, 311, 76–84.
  • [3] DANIELS “DAN” A.U., TOOMS R.E., HARKESS J.W., Arthroplasty, Introduction and Overview, [in:] Campbell’s Operative Orthopaedics, Canale T.S., Mosby, St. Louis, London, Sydney, Toronto, ed. 9, 1998, Vol. 1, 211–231.
  • [4] DeLEE J.G., CHARNLEY J., Radiological demarcation of cemented sockets in total hip replacement, Clin. Orthop., 1976, 121, 20–32.
  • [5] DRAGAN S., Badania nad przebudową adaptacyjną tkanki kostnej w otoczeniu trzpienia endoprotezy bezcementowej, monografia habilitacyjna, Akademia Medyczna we Wrocławiu, Wrocław, 2004.
  • [6] HARKES J.W., Arthroplasty of Hip, [in:] Campbell’s Operative Orthopaedics, Canale S.T., Mosby, St. Louis, Chicago, New York, London, Sydney, Toronto, ed. 9, 1998, Vol. I, 296–471.
  • [7] HARRIS W.H., Osteolysis and particle disease in hip replacement, Acta Orthop. Scand., 1994, 65 (1), 113–123.
  • [8] HERBERTS P., MALCHAU H., How outcome studies hale changed total hip arthroplasty practices in Sweden, Clin. Orthop., 1997, 344, 44–60.
  • [9] HUO M.H., BROWN B.S., What’s new in hip arthroplasty, J. Bone Joint Surg., 2003, 85-A (9), 1852–1864.
  • [10] KAVANAGH B.F., FITZGERALD R.H., Multiple revisions for failed total hip arthroplasty not associated with infection, J. Bone Joint Surg., 1987, 69-A (8), 1144–1149.
  • [11] KEENER J.D., CALLAGHAN J.J., GOETZ D.D., PEDERSON D.R., SULLIVAN P.M., JOHNSON R.C., Twenty-five-year results after Charnley total hip arthroplasty in patients less than fifty years old, J. Bone Joint Surg., 2003, 85-A (6), 1066–1072.
  • [12] KUSZ D. The application of the densitometry research In estimation of total hip arthroplasty results of the hip joint with regard to the computer simulation of stress distributions in the osseous tissue, postdoctoral dissertation, 1998.
  • [13] MANTLEY M.T., CAPELLO W.N., D’ANTONIO J.A., EDIDIN A.A., GEESINK G.T., Fixation of acetabular cups without cement in total hip arthroplasty, J. Bone Joint Surg., 1998, 80-A (8), 1175–1185.
  • [14] MARTELL J.M., PIERSON R.H., JACOBS J.J., ROSENBERG A.G., MALEY M., GALANTE J.O., Primary total hip reconstruction with a titanium fiber-coated prosthesis inserted without cement, J. Bone Joint Surg., 1993, 75-A (4), 554–571.
  • [15] MORSCHER E., BEREITER H., LAMPERT C., Cementless pressfit cup, Clin. Orthop., 1989, 249, 12–20.
  • [16] MORSCHER E., Noncemented acetabular fixation in primary total hip replacement, [in:] Endoprosthetics, Morscher E.W., Springer-Verlag, Berlin, Heidelberg, 1995, 143–179.
  • [17] MORSCHER E.W., ELKE R., BERLI B., Classification and treatment methods of acetabular deficiencies, [in:] Surgical Techniques in Orthopaedics and Traumatology, EFORT, Elsevier, Paris, Vol. 3, 55–450-B-10.
  • [18] MULROY R.D., HARRIS W.H., The effect of improved cementing techniques on component loosening in total hip replacement, J. Bone Joint Surg., 1990, 72-B (5), 757–760.
  • [19] PITTO R.P., SCHIKORA N., Acetabular reconstruction In developmental hip dysplasia using reinforcement ring with hook, Int. Orthop., 2004, 28 (4), 202–205.
  • [20] SCHMALZRIED T.P., JASTY M., HARRIS W.H., Periprosthetic bone loss in total hip arthroplasty, J. Bone Joint Surg., 1992, 74-A, 849–863.
  • [21] STREICHER R.M., Tribology of artificial joints, [in:] Endoprosthetics, Morscher E.W., Springer-Verlag, Berlin, Heidelberg, 1995, 34–48.
  • [22] VASU R., CARTER D.R., HARRIS W.H., Stress distributions In the acetabular region I. Before and after total joint replacement, J. Biomech., 1982, 15, 155–164.
  • [23] WALL A., DRAGAN S., Niektóre aspekty alloplastyki rewizyjnej stawu biodrowego w świetle rocznej działalności Rejestru Wszczepów Ortopedycznych Usuniętych, Chir. Narz. Ruchu Ortop. Pol., 1999, 64 (6), 627–634.
  • [24] WALL A., Clinical aspects of total hip arthroplasty, Acta of Bioengineering and Biomechanics, 2002, 4, Suppl. 1, 39–46.
  • [25] WEBER D., SCHAPER L.A., POMEROY D.L., BADENHAUSER Jr. W.E., CURRY J.I., SMITH M.W., Cementless hemispheric acetabular component in total hip replecement, Int. Orthop., 2000, 24 (3), 130–133.
  • [26] WILKINSON J.M., GORDON A., STOCKLEY I., Experience with the Plasmacup – early stability, wear, remodeling and outcome, Int. Orthop., 2003, 27, Suppl. 1, 16–19.
  • [27] WILSON-MAC DONALD J., MORCHER E., MASAR Z., Cementless uncoated polyethylene acetabular components in total hip replecement, J. Bone Joint Surg., 1990,72-B (2), 423–430.
  • [28] WITVOET J., Classification of total hip arthroplasties, [in:] Surgical Techniques in Orthopaedics and Traumatology, EFORT, Elsevier, Paris, Vol. 3, 55–430-D-10.
  • [29] WŁODARSKI J., Stabilność endoprotez cementowych stawu biodrowego w świetle badań histopatologicznych, numerycznych i eksperymentalnych, Bio-Algorithms and Med.-Systems, 2005, Vol. 1, No. 1/2.
  • [30] WOLFF J., Das Gesetz der Transformation der Knochen, Hirschwald, Berlin, 1892.
  • [31] YANG R.S., LIU T.K., Immunohistochemical analysis of matrix proteolytic enzymes in the periprosthetic tissue in the patients with loosening prostheses, Tahoku J. Exp. Med., 1998, Vol. 184, No. 2.