Application of holographic interferometry and speckle photography in the evaluation of mandible stabilization techniques

Wybrane pełne teksty z tego czasopisma
Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
Application of the holographic interferometry and speckle photography in the primary stability determination of a mandible undergoing the bilateral sagittal split osteotomy (BSSO) is described. Measurements were carried out on Synbone models of human mandibles representing three different techniques of stabilisation. The maximum value criterion of the cut edge displacement components was used for the evaluation of the devices applied (miniplates and bicortical screws). A hybrid technique (miniplate with bicortical screw) of the mandible stabilisation is proposed.
Rocznik
Strony
67--73
Opis fizyczny
Bibliogr. 21 poz., il.
Twórcy
autor
autor
Bibliografia
  • [1] MARENTETTE L., Miniplate osteosynthesis of mandible fractures, Operative Techniques in Otolaryngology - Head and Neck Surgery, 1995, No. 2, 86-88.
  • [2] ZACHARIADES N., MEZITIS M., RALLIS G., An audit of mandibular fractures treated by intermaxillary fixation, intraosseous and compressing plating, British J. of Oral and Maxillofacial Surgery, 1996, 34, 293-297.
  • [3] RENTON T.F., WIESENFELD D., Mandibular fracture osteosynthesis: a comparison of three techniques, British J. of Oral and Maxillofacial Surgery, 1996, 34, 166-173.
  • [4] POTTER J., ELLIS E., Treatment of mandibular angle fractures with a malleable noncompression miniplate, J. of Oral and Maxillofacial Surgery, 1999, 57, 288-292.
  • [5] CHOI B.H., YOO J.H., KIM K.N., KANG H.S., Stability testing of a two miniplate fixation technique for mandibular angle fractures. An in vitro study, Journal of Cranio-Maxillofacial Surgery, 1995, 23, 122-125.
  • [6] THARANON W., Comparison between the rigidity of bicortical screws and a miniplate for fixation of a mandibular setback after a simulated bilateral sagittal split osteotomy, J. of Oral and Maxillofacial Surgery, 1998, 56, 1055-1058.
  • [7] SCHIERLE H.P., SCHMELZEISEN R., PYTLIK C., One- or twoplate fixation of mandibular angle fractures? Journal of Maxillofacial Surgery, 1997, 25, 162-168.
  • [8] FELLER K.-U., RICHTER G., SCHNEIDER M., ECKELT U., Combination of microplate and miniplate for osteosynthesis of mandibular fractures: an experimental study, Int. Journal of Oral and Maxillofacial Surgery, 2002, 31, 78-83.
  • [9] HAUG R.H., PETERSON G.P., A biomechanical evaluation of mandibular condyle fracture plating techniques, J. of Oral and Maxillofacial Surgery, 2002, 60, 73-80.
  • [10] PETERSON G.P., HAUG R.H., Van SICKEL J., A biomechanical evaluation of bilateral sagittal ramus osteotomy fixation techniques, J. of Oral and Maxillofacial Surgery, 2005, 63, 1317-1324.
  • [11] CHIODO T.A., ZICCARDI V.B., JANAL M., SABITINI Ch., Failure strength of 2.0 locking versus 2.0 conventional synthes mandibular plates: a laboratory model, J. of Oral and Maxillofacial Surgery, 2006, 64, 1475-1479.
  • [12] TAMS J., van LOON J.-P., OTTEN E., ROZEMS F.R., BOS R.R.M., A three-dimensional study of bending and torsion moments for different fracture sites in the mandible: an in vitro study, Int. Journal of Oral and Maxillofacial Surgery, 1997, 26, 383-388.
  • [13] KROMKA M., MILEWSKI G., Experimental and numerical approach to chosen types of mandibular fractures cured by means of miniplate osteosynthesis, Acta of Bioengineering and Biomechanics, 2007, Vol. 9, No. 2, 49-54.
  • [14] MEYER CH., SERHIR L., BOUTEMI P., Experimental evaluation of three osteosynthesis devices used for stabilizing condylar fractures of the mandible, Journal of Cranio-Maxillofacial Surgery, 2006, 34, 173-181.
  • [15] MEYER CH., MARTIN E., KAHN J.-L., ZINK S., Development and biomechanical testing of a new osteosynthesis plate (TCP®) designed to stabilize mandibular condyle fractures, Journal of Cranio-Maxillofacial Surgery, 2007, 35, 84-90.
  • [16] TRAUNER R., OBWEGESER H., Zur Operationstechnik bei der Progenie und andersen Unterkieferanormalies, Dtsch. Zahn-Mund-Kieferhelik., 1955, 23, 1-2.
  • [17] DAL PONT G., Retromolar osteotomy for the correction of prognatism, J. of Oral Surgery, 1961, 19, 1.
  • [18] ARMSTRONG J.E.A., LAPOINTE H.J., HOGG N.J.V., KWOK A.D., Preliminary investigation of the biomechanics of internal fixation of sagittal split osteotomies with miniplates, Journal of Oral Maxillofacial Surgery, 2001, 59, 191-195.
  • [19] ERF R.K.(ed.), Holographic Nondestructive Testing, Academic Press, New York, London, San Francisco, 1974.
  • [20] ERF R.K., Speckle Metrology, Academic Press, New York, London, San Francisco, 1978.
  • [21] SHETTY V., FREYMILLER E., MCBREARTY D. et al., Experimental analysis of functional stability of sagittal split ramus osteotomies secured by miniplates and position screws, J. of Oral and Maxillofacial Surgery, 1996, 54, 13-17.