PL EN


Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Tytuł artykułu

Metacarpophalangeal joint kinematics during a grip of everyday objects using the three-dimensional motion analysis system

Autorzy
Wybrane pełne teksty z tego czasopisma
Identyfikatory
Warianty tytułu
Języki publikacji
EN
Abstrakty
EN
This paper deals with the way of using the device for three-dimensional motion analysis allowing the interaction between the movable segments of the hand to be described. The aims of this study were to investigate the angular patterns of the MCP joints for the fingers I–V during the grip of four commonly used objects and to compare the results between the dominant/non-dominant hands and in both male and female groups. The experiment was carried on 48 right-handed subjects (24 males and 24 females) selected at random, aged between 20 and 23. The 3-D motion capture system, that was used, consisted of 5 strobe cameras and a hand model consisting of 15 kinematic pairs with the total mobility of 20 degrees of freedom. In this study, mean, standard deviation, median, minimum, maximum and the ranges of flexion/extension and radial/ulnar deviation were separately described for each finger MCP joint. For statistical analysis and in search for the variability of angular parameters of MCP joints during a grip, the Mann–Whitney U test was used.
Rocznik
Strony
79--85
Opis fizyczny
Bibliogr. 20 poz., il.
Twórcy
autor
Bibliografia
  • [1] SWANSON A.B., HAGERT C.G., Evaluation of impairement of hand function, J. Hand Surg., 1983, 8(5), 709-722.
  • [2] FREIVALDS A., Biomechanics of the upper limbs: mechanics, modelling, and musculoskeletal injuries, CRC Press, New York, 2004.
  • [3] CHIU H-Y., SU F.C., WANG S-T. et al., The motion analysis and goniometry of the finger joints, J. Hand Surg. (British and European Volume), 1998, 23B(6), 788-791.
  • [4] RASH G.S., BIELLIAPPA P.P., WACHOWIAK M.P. et al., A demonstration of the validity of a 3-D video motion analysis method for measuring finger flexion and extension, J. Biomech., 1999, 32, 1337-1341.
  • [5] KUO L.-C., SU F.-C., CHIU H.-Y. et al., Feasibility of using a video-based motion analysis system for measuring thumb kinematics, J. Biomech., 2002, 35, 1499-1506.
  • [6] DEGEORGES R., OBERLIN C., Measurement of three-jointfinger motions: reality or fancy? A three-dimensional anatomical approach, Surg. Radiol. Anat., 2003, 25, 105-112.
  • [7] DEGEORGES R., PARASIE J., MITTON D. et al., Three-dimensional rotations of human three-joint fingers: an optoelectronic measurement. Preliminary results, Surg. Radiol. Anat., 2005, 27, 34-50.
  • [8] CARPINELLA I., MAZZOLENI P., RABUFFETTI M. et al., Experimental protocol for the kinematic analysis of the hand: Definition and repeatability, Gait Posture, 2006, 23, 445-454.
  • [9] BAZAŃSKI T., The kinematic analysis of the hand joints parameters during every day activities using the three-dimensional analysis motion system Vicon 250, Master's thesis, AWF, Kraków, 2006.
  • [10] DAVIDOFF N.A., FREIVALDS A., A graphic model of the human hand using CATIA, Int. J. Ind. Ergon., 1993, 12(4), 255-264.
  • [11] OLDFIELD R.C., The assessment and analysis of handedness: The Edinbourgh Inventory, Neuropsychologia, 1971 Mar, 9(1), 97-113.
  • [12] RANSIL B.J., SCHACHTER S.C., Test-retest reliability of the Edinbourgh Handedness Inventory and Global Handedness preference measurements, and their correlation, Percept. Mot. Skills., 1994 Dec, 79(3), 1355-1372.
  • [13] CHENG P.L., PEARCY M., A three-dimensional definition for the flexion/extension and abduction/adduction angles, Med. Biol. Eng. Comput., 1999 Jul, 37(4), 440-444.
  • [14] NORKIN C.C., LEVANGIE P.K., Joint structure and function. A comprehensive analysis, F.A. Davis Company, Philadelphia, 2000.
  • [15] INGRAM J.M., KöRDING K.P., HOWARD I.S. et al., The statistic of natural hand movements, Exp. Brain. Res., 2008, 188, 223-236.
  • [16] BAKER N.A., CHAM R., CIDBOY E.H. et al., Kinematics of the fingers and hands during computer keyboard use, Clin. Biomech., 2007, 22, 34-43.
  • [17] PIENIĄŻEK M., CHWAŁA W., SZCZECHOWICZ J. et al., Upper limb joint mobility ranges during activities of daily living determined by three-dimensional motion analysis, Ortop. Traumatol. Rehabil., 2007, 9(4), 413-422.
  • [18] CERVERI P., DE MOMI E., LOPOMO N., Finger kinematic modeling and real-time hand motion estimation, Ann. Biomed. Eng., 2007, 35(11), 1989-2002.
  • [19] ALLEN C.R., SU Y., GENG D., 3D hand modelling and analysis using data gloves: theory and its application in Parkinson's disease, Acta Bioeng. Biomech., 2002, 4(1), 3-30.
  • [20] GÜLKE J., WACHTER N.J., GEYER T. et al., Motion coordination patterns during cylinder grip analyzed with a sensor glove, J. Hand Surg. (American Volume), 2010, 35(5), 797-806.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BPBA-0009-0017
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.