Tytuł artykułu
Wybrane pełne teksty z tego czasopisma
Identyfikatory
Warianty tytułu
Języki publikacji
Abstrakty
In this study, the authors assess the strength of proximal humerus fracture fixation using different methods. The strength, while pulling out the chosen single Kirschner wires implanted in porcine bone, has been examined. Tests concerning the strength of fixation with different types of implants have been carried out on prepared models. We observed the maximum strength of the bone–single wire coupling for Kirschner wires of a 2.5 mm diameter with 100 mm thread where mean was 2396 N (SD 345). The mean strength of the 4 wires fracture fixation for Kirschner wires of a 2.5 mm diameter with 100 mm thread was 736 N (SD 229) and was similar to Kirschner wires of a 2.5 mm diameter with 10 mm thread where mean was 709 N (SD 191).
Czasopismo
Rocznik
Tom
Strony
29--35
Opis fizyczny
Bibliogr. 28 poz., rys., tab.
Twórcy
autor
autor
autor
autor
autor
autor
- Department of Biomechanics, Faculty of Rehabilitation, Józef Piłsudski Academy of Physical Education, Warszawa, m.wychowanski@awf.edu.pl
Bibliografia
- [1] BENGNER U., JOHNELL O., REDLUND-JOHNELL I., Changes in the incidence of fracture of the upper end of the humerus during a 30-year period. A study of 2125 fractures, Clin. Orthop. Relat. Res., 1988, 231, 179–182.
- [2] HORAK J., NILSSON B.E., Epidemiology of fracture of the upper end of the humerus, Clin. Orthop. Relat. Res., 1975, (112), 250–253.
- [3] LEYSHON R.L., Closed treatment of fractures of the Proxima humerus, Acta Orthop. Scan., 1984, 55(1), 48–51.
- [4] LIND T., KRONER K., JENSEN J., The epidemiology of fractures of the proximal humerus, Arch. Orthop. Trauma Surg., 1989(5), 108, 285–287.
- [5] CORNELL C., Master techniques in orthopaedic surgery, fractures, Lippincott-Raven Publishers, Philadelphia, 1998.
- [6] HAWKINS R.J., BELL R.H., GURR K., The three-part fractures of the proximal part of the humerus. Operative treatment, J. Bone Joint Surg. Am., 1986, 68(9), 1410–1414.
- [7] HERSCOVICI D.J., SAUNDERS D.T., JOHNSON M.P., SANDERS R., DIPASQUALE T., Percutaneous fixation of proximal humeral fractures, Clin. Orthop. Relat. Res., 2000, (375), 97–104.
- [8] KOVAL K.J., GALLAGHER M.A., MARSICANO J.G., CUOMO F., MCSHINAWY A., ZUCKERMAN J.D., Functional outcome after minimally displaced fractures of the proximal part of the humerus, J. Bone Joint Surg. Am., 1997, 79(2), 203–207.
- [9] NEER C.S. 2nd., Displaced proximal humeral fractures. I. Classification and evaluation, I. Clin. Orthop. Relat. Res., 1987, (223), 3–10.
- [10] BROOKS C.W., REVELL W.J., HEATLEY F.W., Vascularity of the humeral head after proximal humeral fractures. An anatomical cadaver study, J. Bone Joint Surg. Brit., 1993, 75(1), 132–136.
- [11] JABERG H., WARNER J.J., JAKOB R.P., Percutaneous stabilisation of unstable fractures of the humerus, J. Bone Joint Surg. Am., 1992, 74(4), 508–515.
- [12] MÜNST P., KUNER E.H., Osteosynthesen bei dislozierten Humeruskopffrakturen, Orthopäde, 1992, 21(2), 121–130.
- [13] WILLIAMS G.R. JR., WONG K., Two-part and three-part fractures: open reduction and internal fixation versus closed reduction and percutaneous pinning, Orthop. Clin North Am., 2000, 31(1), 1–21.
- [14] NICHOLAS J.M., HERSHMAN E., The upper extremity in sports medicine, Mosby-Year Book Inc., 1995.
- [15] WHEELER D.L., COLVILLE M.R., Biomechanical comparison of intramedullary and percutaneous pin fixation for proximal humeral fracture fixation, J. Orthop. Trauma, 1997, 11(5), 363–367.
- [16] AHMAD C.S., LEE T.Q., ELATTRACHE N.S., Biomechanical evaluation of a new ulnar collateral ligament reconstruction technique with interference screw fixation, Am. J. Sports Med., 2003, 31(3), 332–337.
- [17] BEINGESSNER D.M., DUNNING C.E., BEINGESSNER C.J., JOHNSON J.A., KING G.J., The effect of radial head fracture size on radiocapitellar joint stability, Clin. Biomech., 2003, 18(7), 677–681.
- [18] VOOR M., ANTOCI V., ANTOCI V. JR., ROBERTS C.S. The effect of wire plane tilt and olive wires on proximal tibia fracture fragment stability and fracture site motion, J. Biomech., 2005, 38(3), 537–541.
- [19] VOOR M.J., KHALILY C., Halo pin loosening: a biomechanical comparison of experimental and conventional designs, J. Biomech., 1998, 31(4), 397–400.
- [20] WIDJAJA W., HARTUNG C., Biomechanical comparison of different fixations of femur-interlocking-nails, Clin. Biomech., Avon, Bristol, 2001, 16(8), 702–705.
- [21] YERBY S.A., EHTESHAMI J.R., MCLAIN R.F., Loading of pedicle screws within the vertebra, J. Biomech., 1997, 30(9), 951–954.
- [22] KAULESAR SUKUL D.M., JOHANNES E.J., MARTI R.K., KLOPPER P.J., Biomechanical measurements on scaphoid bone screws in an experimental model, J. Biomech., 1998, 23(11), 1115–1121.
- [23] ROKKANEN P.U., BÖSTMAN O., HIRVENSALO E., MÄKELÄ E.A., PARTIO E.K., PÄTIÄLÄ H., VAINIONPÄÄ S.I., VIHTONEN K., TÖRMÄLÄ P., Bioabsorbable fixation in orthopedic surgery and traumatology, Biomaterials, 2000, 21(4), 2607–2613.
- [24] KOUSA P., JÄRVINEN T.L., POHJONEN T., KANNUS P., KOTIKOSKI M., JÄRVINEN M., Fixation strength of bidegradable screw in anterior cruciate ligament reconstruction, J Bone Joint Surg. Br., 1995, 77(6), 901–905.
- [25] ROHLMANN A., BERGMANN G., GRAICHEN F., MAYER H.M., Placing a bone graft more posteriorly may reduce the risk of pedicle screw breakage: analysis of an unexpected case of pedicle screw breakage, J. Biomech., 1998, 31(8), 763–767.
- [26] BHANDARI M., DEVEREAUX P.J., MCKEE M.D., SCHEMITSCH E.H., Compression plating versus intermedullary nailing of humeral shaft fractures – a meta-analysis, Act. Orthop., 2006, 77(2), 279–284.
- [27] BJÖRKENHEIM J-M., PAJARINEN J., SAVOLAINEN V., Internal fixation of proximal humeral fractures with a locking compression plate, Act. Orthop. Scand., 2004, 75(6), 741–745.
- [28] RICKMAN M., SALEH M., YANG L., Tensioning technique and fixator stability of a circular external fixator with threaded fine wires, J. Biomech., 2006, 39(3), 544–550.
Typ dokumentu
Bibliografia
Identyfikator YADDA
bwmeta1.element.baztech-article-BPB9-0013-0005